6 in 1 Multifunctional Environmental Meter LMEM-A10 a small, handheld device, measures air velocity/temperature, ambient temperature, relative humidity, contact temperature, and light. Designed for one-handed operations, it features a user-friendly key panel easy to operate. It features a large LCD backlight display for easy reading, data hold and Max/Min function, and low battery indicator and auto shut off.
| Temperature Measurement Range | -10℃ to 60℃ |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ± 1.5℃ |
| Relative Humidity Range | 20% to 80% RH |
| Relative Humidity Resolution | 0.1 % RH |
| Relative Humidity Accuracy | ± 3 % RH @25°C |
| Wind Velocity | 0.5 to 20 m/s, 1.8 to 72 km/h, 1.6 to 65.7 ft/s, 0.9 to 38.9 knots |
| Wind Resolution | 0.1 m/s, 0.1 km/h, 0.1 ft/s, 0.1 knots |
| Wind Accuracy | ± 3 % of reading + 10 digits |
| Air Velocity | 0 to 999900 CMM, 0 to 999900 CFM |
| Air Resolution | 0 to 999.9 m2, 0 to 999.9 ft2 |
| Air Accuracy | ± 3 % of reading + 10 digits |
| Sound (noise) Level | 30 to 130 dB (A), 35 to 130 dB (C) |
| Sound Level Resolution | 0.1 dB |
| Sound Level Accuracy | ± 1.5 dB |
| Test Condition | 94 dB, 4 kHz sine wave |
| Respond Frequency | 100 to 8000 kHz |
| Test Respond Time | About 2 time/second |
| Illuminance Range | 0 to 2000 Lux, X10 (20000), X100 (50000) |
| Illuminance Resolution | 1 Lux, 10 Lux, 100 Lux |
| Illuminance Accuracy | ± 5 % of reading + 10 digits at color temperature 2850 K calibrated to standard incandescent lamp at color temperature 2856 K |
| Display | LCD (backlight screen) |
| Power Supply | 6F22 (9V) |
| Auto off- Power Cut Off | Yes |
| Dimension (L×W×H) | 280×89×50 mm |
| Weight | 430 g |
| Gas Detected | Nitrogen N2 |
| Detection principle | Electrochemical principles |
| Measurement Range | 0 to 100 %.Vol |
| Sampling Method | Diffusion | ||||||
| Working conditions |
| ||||||
| Explosion proof grade | Exia II CT3 |
| Measurement principle | Non-dispersive infrared (NDIR) |
| Gas Detected | SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.) |
| Detection Uncertainty | <1.5 % F.S |
| Gas Detected | O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3 |
| Detection principle | Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC) |
| Measurement Range | O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPM |
| Sampling | With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection |
| Gas | Ethylene C2H4 |
| Measure Range | 0 to 1000 ppm |
| Sampling method | Diffusion |
| Measurement principle | Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas) |
| Detector gas | Flammable gases, oxygen gas, toxic and harmful gases |
| Gas detected | NO<sub>2</sub> |
| Detection principle | Electrochemistry |
| Sampling method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. |
| Gas detected | Sulfur dioxide SO<sub>2</sub> |
| Detection principle | Electrochemistry |
| Sampling method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. |
| Sampling method | Diffusion |
| Sensor type | CO2: solid electrolyte sensor, O2:electrochemical sensor |
| Detection range | CO2:0.04 to 5.00 % and O2:0.0 to 30.0 % |
| Measuring range | 0 ∼ 125 Pa |
| Accuracy | 0 ± 0.2 Pa (liner error)<hr> ± 1 % |
| Measurement range | 0 ppm ∼ 5 ppm |
| Resolution | 0.001 ppm ( 0 ppm ∼ 5 ppm ) |
| Temperature range | ˗ 40 °C ∼ 120 °C |
| Ozone measurement range | 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional ) |
| Flow rate | 1.5 L/min |
| Accuracy | 0.01 ppm or 3 % of reading |
| Ozone measurement range | 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm |
| Flow rate | 1 L/min |
| Accuracy | 0.01 ppm |