Portable SO2Gas Detector LPSG-A20

Portable SO2Gas Detector LPSG-A20 is a fast response and high accuracy gas measurement device with 0 to 1000 ppm range. Its internal sampling pump with fast sampling speed and high flow rate, ensures the accurate response time of the detector. Portable nature, small size ait offers role in special high intensity engineering plastic housing, suitable for different kinds of situation and environment. The gas concentration unit ppm and mg/m3 can be shifted quickly and also the local time can be shown on the screen.

Gas detected Sulfur dioxide SO<sub>2</sub>
Detection principle Electrochemistry
Sampling method Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
Measure range 0 to1000 ppm
Resolution 1 ppm
Precision 2 % fs
Signal output High-speed data transmission by USB, available for data downloading and printing
Response time ≤ 10 s
Repeatability ≤ ± 1 %
Zero shift ≤ ± 1 % (fs /year)
Operating language English
Temperature -20° C to 50 °C
Explosion-proof Exib ll CT4
Alarm mode Sound, light, vibration
Recovery time ≤ 10 s
Linearity error ≤ ± 1 %
Display LCD dot matrix display
Gas unit Units are switchable
Humidity 0 to 95 % RH
Degree of protection IP66
Operating time 100 h (pump off)
Dimension 205 × 75 × 32 mm
Weight 300 g
  • Monitor the SO2gas concentration in environment
  • Built in micro sampling pump and 10 grades of suction are available
  • High speed data transmission by USB, which can download and print data
  • Equipped by self-calibration and zero calibration function, makes the detection more accurate and reliable
  • Feature by aluminium suitcase and charging adapter
  • Two stages alarm with sound and light, alarm point is settable
  • The gas concentration unit ppm and mg/m3 can be shifted quickly
  • Rechargeable lithium polymer battery of large capacity
  • LCD dot matrix display, the gas type, unit, concentration
  • Employing pumping sampling method and the pumping suction is adjustable

Portable SO2Gas Detector is used in petrochemical and chemical industry, agriculture environment protection, electronic, food, pharmaceutical industry, bio-pharmaceutical plant, green household and Furniture, flooring, wallpaper, paint, gardening, interior decoration and renovation, dyes, paper, medical, corrosion, fermentation process.

Measurement principle Non-dispersive infrared  (NDIR)
Gas Detected SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.)
Detection Uncertainty <1.5 % F.S
Detection Resolution 0.1ppm
Gas detected NO<sub>2</sub>
Detection principle Electrochemistry
Sampling method Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
Measure range 0 to1000 ppm
Sampling With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection
Gas Ethylene C2H4
Measure Range 0 to 1000 ppm
Resolution 1ppm
Sampling method Diffusion
Measurement principle Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas)
Detector gas Flammable gases, oxygen gas, toxic and harmful gases
Response time
CO2 < 10 s
O2, flammable gases < 20 s
CO, H2S, SO2, NO, ClO2, NO2, H2 < 30 s
HCN, NH3, PH3 < 100 s
Sampling Method Diffusion
Working conditions
Temperature -20 to 50°C
Pressure 0.9 to 1.1 (standard atmospheric pressure)
Humidity 10 to 95 % RH (no dew condensation)
Explosion proof grade Exia II CT3
Protection grade IP65
Gas Detected O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3
Detection principle Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC)
Measurement Range O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPM
Resolution O2: 0.01% VOL, CH4: 1 PPM, CO2:1 PPM VOC:1 PPM, CO:0.1 PPM, H2S: 0.1 PPM SO2: 0.01 PPM, CL2: 0.01 PPM, NO2: 0.01 PPM, NH3:0.01 PPM
Gas Detected Nitrogen N2
Detection principle Electrochemical principles
Measurement Range 0 to 100 %.Vol
Resolution 0.01 %VOL
Sampling method Diffusion
Sensor type CO2: solid electrolyte sensor, O2:electrochemical sensor
Detection range CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %
Detection accuracy CO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale)
Measuring range ± 500 Pa
Repeatability ± 0.2 % FS
Resolution 0.1 Pa
Sampling rate 0.5 s
Measuring range 0 ∼ 125 Pa
Accuracy 0 ± 0.2 Pa (liner error)<hr> ± 1 %
Operating temperature range 0 °C ∼ 50 °C
Operational humidity ˂ 85 RH
Sampling method Diffusion
Sensor type CO2: solid electrolyte sensor, O2:electrochemical sensor
Detection range CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %
Detection accuracy CO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale)
Sampling With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection
Gas Ethylene C2H4
Measure Range 0 to 1000 ppm
Resolution 1ppm
Sampling Method Diffusion
Working conditions
Temperature -20 to 50°C
Pressure 0.9 to 1.1 (standard atmospheric pressure)
Humidity 10 to 95 % RH (no dew condensation)
Explosion proof grade Exia II CT3
Protection grade IP65
Ozone measurement range 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm
Flow rate 1 L/min
Accuracy 0.01 ppm
Measuring time 10 seconds
Measurement range 0 ppm ∼ 5 ppm
Resolution 0.001 ppm ( 0 ppm ∼ 5 ppm )
Temperature range ˗ 40 °C ∼ 120 °C
Humidity range 0 % ∼ 100 % RH
Capacity 50 kg
Accuracy 1 g
Speed 1 s
Value stable time 2 s
Temperature Measurement Range -10℃ to 60℃
Temperature Resolution 0.1°C
Temperature Accuracy ± 1.5℃
Relative Humidity Range 20% to 80% RH