Online ozone meter LOOM-A10 is based on advanced microprocessor technology. It monitors the changes of ozone concentration in the air and can automatically change the ozone measurement ranges. The UV absorption for monitoring low concentration of ozone is based on Beer-Lambert law. Features like real-time monitoring, auto zero calibration and built-in printer makes this unit suitable for most atmospheric monitoring requirements.
| Ozone measurement range | 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional ) |
| Flow rate | 1.5 L/min |
| Accuracy | 0.01 ppm or 3 % of reading |
| Resolution | 0.001 ppm |
| Sampling Time | 10 seconds |
| Boot time | ≥ 30 |
| Operating temperature | 10 °C ∼ 40 °C |
| Operational humidity | 10 % ∼ 90 % RH |
| Gas pipe diameter | Ø 4 mm |
| Output mode | 4 ∼ 20 mA, 0 ∼ 5 V DC; Modbus 485 |
| Power | 24 VDC ± 10 % |
| Dimensions | 150 x 90 x 325 mm |
| Weight | 1.9 kgs |
| Gas detected | Sulfur dioxide SO<sub>2</sub> |
| Detection principle | Electrochemistry |
| Sampling method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. |
| Sampling Method | Diffusion | ||||||
| Working conditions |
| ||||||
| Explosion proof grade | Exia II CT3 |
| Gas detected | NO<sub>2</sub> |
| Detection principle | Electrochemistry |
| Sampling method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. |
| Gas Detected | Nitrogen N2 |
| Detection principle | Electrochemical principles |
| Measurement Range | 0 to 100 %.Vol |
| Gas Detected | O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3 |
| Detection principle | Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC) |
| Measurement Range | O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPM |
| Sampling method | Diffusion |
| Sensor type | CO2: solid electrolyte sensor, O2:electrochemical sensor |
| Detection range | CO2:0.04 to 5.00 % and O2:0.0 to 30.0 % |
| Measurement principle | Non-dispersive infrared (NDIR) |
| Gas Detected | SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.) |
| Detection Uncertainty | <1.5 % F.S |
| Sampling method | Diffusion |
| Measurement principle | Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas) |
| Detector gas | Flammable gases, oxygen gas, toxic and harmful gases |
| Sampling | With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection |
| Gas | Ethylene C2H4 |
| Measure Range | 0 to 1000 ppm |
| Measuring range | 0 ∼ 125 Pa |
| Accuracy | 0 ± 0.2 Pa (liner error)<hr> ± 1 % |
| Measurement range | 0 ppm ∼ 5 ppm |
| Resolution | 0.001 ppm ( 0 ppm ∼ 5 ppm ) |
| Temperature range | ˗ 40 °C ∼ 120 °C |
| Ozone measurement range | 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm |
| Flow rate | 1 L/min |
| Accuracy | 0.01 ppm |
| Temperature Measurement Range | -10℃ to 60℃ |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ± 1.5℃ |