Portable Single Gas Detector LPSG-A10 is a compact, lightweight detector. Detects the concentration of flammable gases, oxygen gas, and different types of toxic and harmful gases. It features large capacity lithium battery with long standby time, adjustable calibration concentration, and manual cancellation mode of vibration alarms.
| Sampling method | Diffusion | ||||
| Measurement principle | Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas) | ||||
| Detector gas | Flammable gases, oxygen gas, toxic and harmful gases | ||||
| Response time |
| ||||
| Detection error | ± 5 % F.S. | ||||
| Explosion grade | Exia II CT3 | ||||
| Operation mode | Touch push keys | ||||
| Display | LCD display | ||||
| Working temperature | -20 to 55°C | ||||
| Environment humidity | 0 to 95 % RH (non-condensation) | ||||
| Storage temperature | 0 to 40°C | ||||
| Battery | 4.2 V lithium battery, 1700 mA/h | ||||
| Power supply | Rechargeable lithium battery, continuous working up to 24 hours | ||||
| Dimension | 125 × 66 × 42 mm | ||||
| Weight | 105 g | ||||
| HS Code | 9027100090 |
| Gas detected | NO<sub>2</sub> |
| Detection principle | Electrochemistry |
| Sampling method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. |
| Sampling | With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection |
| Gas | Ethylene C2H4 |
| Measure Range | 0 to 1000 ppm |
| Sampling method | Diffusion |
| Sensor type | CO2: solid electrolyte sensor, O2:electrochemical sensor |
| Detection range | CO2:0.04 to 5.00 % and O2:0.0 to 30.0 % |
| Measurement principle | Non-dispersive infrared (NDIR) |
| Gas Detected | SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.) |
| Detection Uncertainty | <1.5 % F.S |
| Gas Detected | O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3 |
| Detection principle | Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC) |
| Measurement Range | O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPM |
| Gas Detected | Nitrogen N2 |
| Detection principle | Electrochemical principles |
| Measurement Range | 0 to 100 %.Vol |
| Sampling Method | Diffusion | ||||||
| Working conditions |
| ||||||
| Explosion proof grade | Exia II CT3 |
| Gas detected | Sulfur dioxide SO<sub>2</sub> |
| Detection principle | Electrochemistry |
| Sampling method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. |
| Measuring range | 0 ∼ 125 Pa |
| Accuracy | 0 ± 0.2 Pa (liner error)<hr> ± 1 % |
| Measurement range | 0 ppm ∼ 5 ppm |
| Resolution | 0.001 ppm ( 0 ppm ∼ 5 ppm ) |
| Temperature range | ˗ 40 °C ∼ 120 °C |
| Ozone measurement range | 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional ) |
| Flow rate | 1.5 L/min |
| Accuracy | 0.01 ppm or 3 % of reading |
| Ozone measurement range | 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm |
| Flow rate | 1 L/min |
| Accuracy | 0.01 ppm |
| Temperature Measurement Range | -10℃ to 60℃ |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ± 1.5℃ |