Type II Water Purification System LTWP-B12

Type II Water Purification System LTWP-B12 is a 30 L capacited revolutionary, modular design which helps in elimination of large amount of salts and other minerals from water using 2 stages of RO. It provides Type II level water with consistency and reliability with a TOC level of < 20 ppb. Remove approximately 98% of inorganic ions and 99% of all dissolved organic substances. Equipped with easy replaceable filters. It’s designed to deliver compliant purified water with clear quality parameters and care free maintenance

Output of Pure water &ge; 30 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 30 L
Configuration Benchtop
Output of Ultrapure water &ge; 1- 1.5 L / min
Resistivity at 25 °C 10-16 M &Omega;. cm
Conductivity at 25 °C &le; 5 µs / cm
TOC < 20 ppb
Absorbance ( 254 nm ) &le; 0.001
Reactive Silica ( SiO2 ) < 0.01 ppm
Heavy metal < 0.01 ppm
Electrical requirements 220 V / 50 Hz
Power &ge; 450 W
Dimensions ( L x W x H ) 340 x 550 x 530 mm
Weight 40 kg
  • Advanced Double Pass reverse osmosis system for excellent water quality
  • Equipped with 30 L water holding tank
  • TOC level < 20 ppb
    Type II level water produced
  • Source of inlet water – Tap water
  • Benchtop model
  • LCD display to monitor the intake of water pressure and various parameters intuitively
  • Anti-fouling RO membrane prevention programme
  • Online monitoring of water resistance
  • Ease of cleansing , disinfecting and draining waste water
  • Micro filter membrane to filter out pollutants
  • Automatic RO membrane antiscale flushing to extend the life of the RO membrane

Related Products of Type II Water Purification System

This water purification system provides Type II level water with consistency and reliability. It removes approximately 98% of inorganic ions and 99 % of all dissolved organic substances

Output of Pure water &ge; 30 L / hr.
Process Single Pass RO system
Water Type Type II
Water Tank capacity 30 L
Output of Pure water &ge; 20 L / hr.
Process Single Pass RO system
Water Type Type II
Water Tank capacity 30 L
Output of Pure water &ge; 50 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 80 L
Output of Pure water &ge; 50 L / hr.
Process Single Pass RO system
Water Type Type II
Water Tank capacity 80 L
Output of Pure water &ge; 10 L / hr.
Process Single Pass RO system
Water Type Type II
Water Tank capacity 30 L
Output of Pure water &ge; 20 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 30 L
Output of Pure water &ge; 40 L / hr.
Process Single Pass RO system
Water Type Type II
Water Tank capacity 80 L
Output of Pure water &ge; 10 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 30 L
Output of Pure water &ge; 40 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 80 L

Type III Water Purification System

It provides Type III level water which is required for chemical and physical inspection or for washing lab glassware’s

Output of Pure water &ge; 10 L / hr.
Water Type Type III
Configuration Benchtop
Process Double Pass RO system
Output of Pure water &ge; 30 L / hr.
Water Type Type III
Configuration Benchtop
Process Double Pass RO system
Output of Pure water &ge; 20 L / hr.
Water Type Type III
Configuration Benchtop
Process Double Pass RO system
Output 30 liters/hour
Flow rate Up to 2 liters/minute (with pressure tank)
Pure water outlet 2 reverse osmosis water, deionized water
Deionized Water Quality Resistivity: 16 to 18.2 M Ω cm<br/> Bacteria: N/A<br/> Particle (>0.1 µm): N/A
Output 30 liters/hour
Flow rate Up to 2 liters/minute (with pressure tank)
Pure water outlet 2 reverse osmosis water, deionized water
Deionized Water Quality Resistivity: 16 to 18.2 M Ω cm<br/> Bacteria: N/A<br/> Particle (>0.1 µm): N/A
Output 2nd stage RO water 90 liters/hour
Output ultrapure water Up to 2 liters/minute (when tank is full)
Ultrapure Water Quality Resistivity (25°C) 18.2 M Ω cm<br/> TOC: < 3ppb<br/> Bacteria: <0.1 cfu/ml<br/> Particle (>0.2 µm): <1/ml<br/> Endotoxin: <0.001EU/ml<br/> RNases: <1pg/ml<br/> DNases: <5pg/ml
RO Water Quality Conductivity 1st stage RO water: Feed water Conductivity ×5 %<br/> Conductivity 2nd stage RO water: 1 to 5 µs/cm
Water quality Two stage(Type III and type I)
Feed water Tap waterTDS≤400ppm<hr> Water temperature: 5-40℃<hr> Type 3 water ≥10L/h
Conectivity <5 μs/cm@25℃
Resistivity 18.25 MΩ.cm @ 25 ℃
Water quality One stage (Type I)
Feed water RO water /Distilled water<hr> Water temperature: 5 ~ 40℃
Resistivity 18.25 MΩ.cm @ 25 ℃
TOC < 5ppb

Radio Frequency Identification Water Purification System

Radio Frequency Identification Water Purifier are equipped with a RFID Radio Frequency Identification Chip which helps keeping a check on the quality of water in real time. This helps in monitoring of parameters for the purifier

Output of Pure water &ge; 10 L / hr.
Process Double Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Output of Pure water &ge; 30 L / hr.
Process Double Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Output of Pure water &ge; 20 L / hr.
Process Double Pass RO system
Configuration Benchtop
Water Tank capacity 30 L

Type I and Type III Water Purification System

This water purification system is a combinational system that produces Type III water after RO and Type I water after deionization in one cycle

Output of Pure water &ge; 20 L / hr.
Water Type Type I and Type III
Water Tank capacity 30 L
Configuration Benchtop
Output of Pure water &ge; 10 L / hr.
Water Type Type I and Type III
Water Tank capacity 30 L
Configuration Benchtop
Output of Pure water &ge; 30 L / hr.
Water Type Type I and Type III
Water Tank capacity 30 L
Configuration Benchtop