Type II Water Purification System LTWP-A11

Type II Water Purification System LTWP-A11 is a 30 L capacited modular design which meets the needs of basic laboratory water purifier. It provides Type II level water with consistency and reliability with a TOC level of < 20 ppb. Remove approximately 98% of inorganic ions and 99% of all dissolved organic substances.This system produce and reject water at the same time. Equipped with easy replaceable filters. It’s designed to deliver compliant purified water with clear quality parameters and care free maintenance.

Output of Pure water &ge; 20 L / hr.
Process Single Pass RO system
Water Type Type II
Water Tank capacity 30 L
Configuration Benchtop
Output of Ultrapure water &ge; 1- 1.5 L / min
Resistivity at 25 °C 10-16 M &Omega;. cm
Conductivity at 25 °C &le; 10 µs / cm
TOC < 20 ppb
Absorbance ( 254 nm ) &le; 0.001
Reactive Silica ( SiO2 ) < 0.01 ppm
Heavy metal < 0.01 ppm
Electrical requirements 220 V / 50 Hz
Power &ge; 150 W
Dimensions ( L x W x H ) 340 x 550 x 530 mm
Weight 35 kg
  • Advanced Single Pass reverse osmosis system for excellent water quality
  • Equipped with 30 L water holding tank
  • Type II level water produced
    TOC level < 20 ppb
  • Source of inlet water – Tap water
  • Benchtop model
  • LCD display to monitor the intake of water pressure and various parameters intuitively
  • Anti-fouling RO membrane prevention programme
  • Online monitoring of water resistance
  • Ease of cleansing , disinfecting and draining waste water
  • Micro filter membrane to filter out pollutants
  • Automatic RO membrane antiscale flushing to extend the life of the RO membrane

Related Products of Type II Water Purification System

This water purification system provides Type II level water with consistency and reliability. It removes approximately 98% of inorganic ions and 99 % of all dissolved organic substances

Output of Pure water &ge; 50 L / hr.
Process Single Pass RO system
Water Type Type II
Water Tank capacity 80 L
Output of Pure water &ge; 30 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 30 L
Output of Pure water &ge; 40 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 80 L
Output of Pure water &ge; 30 L / hr.
Process Single Pass RO system
Water Type Type II
Water Tank capacity 30 L
Output of Pure water &ge; 10 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 30 L
Output of Pure water &ge; 20 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 30 L
Output of Pure water &ge; 50 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 80 L
Output of Pure water &ge; 10 L / hr.
Process Single Pass RO system
Water Type Type II
Water Tank capacity 30 L
Output of Pure water &ge; 40 L / hr.
Process Single Pass RO system
Water Type Type II
Water Tank capacity 80 L

UV Water Purification System

UV water purification systems destroy the DNA of micro-organisms making the water contamination free. Water produced from UV water purification is contamination free water which is potable for consumption

Output of Pure water &ge; 30 L / hr.
Process Double Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Output of Pure water &ge; 20 L / hr.
Process Double Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Output of Pure water &ge; 10 L / hr.
Process Double Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Output 30 liters/hour
Flow rate Up to 2 liters/minute (with pressure tank)
Pure water outlet 2 reverse osmosis water, deionized water
Deionized Water Quality Resistivity: 16 to 18.2 M Ω cm<br/> Bacteria: N/A<br/> Particle (>0.1 µm): N/A
Output 30 liters/hour
Flow rate Up to 2 liters/minute (with pressure tank)
Pure water outlet 2 reverse osmosis water, deionized water
Deionized Water Quality Resistivity: 16 to 18.2 M Ω cm<br/> Bacteria: N/A<br/> Particle (>0.1 µm): N/A
Water quality Two stage(Type III and type I)
Feed water Tap waterTDS≤400ppm<hr> Water temperature: 5-40℃<hr> Type 3 water ≥10L/h
Conectivity <5 μs/cm@25℃
Resistivity 18.25 MΩ.cm @ 25 ℃
Water quality One stage (Type I)
Feed water RO water /Distilled water<hr> Water temperature: 5 ~ 40℃
Resistivity 18.25 MΩ.cm @ 25 ℃
TOC < 5ppb
Output 2nd stage RO water 90 liters/hour
Output ultrapure water Up to 2 liters/minute (when tank is full)
Ultrapure Water Quality Resistivity (25°C) 18.2 M Ω cm<br/> TOC: < 3ppb<br/> Bacteria: <0.1 cfu/ml<br/> Particle (>0.2 µm): <1/ml<br/> Endotoxin: <0.001EU/ml<br/> RNases: <1pg/ml<br/> DNases: <5pg/ml
RO Water Quality Conductivity 1st stage RO water: Feed water Conductivity ×5 %<br/> Conductivity 2nd stage RO water: 1 to 5 µs/cm

Type III Water Purification System

It provides Type III level water which is required for chemical and physical inspection or for washing lab glassware’s

Output of Pure water &ge; 20 L / hr.
Water Type Type III
Configuration Benchtop
Process Double Pass RO system
Output of Pure water &ge; 10 L / hr.
Water Type Type III
Configuration Benchtop
Process Double Pass RO system
Output of Pure water &ge; 30 L / hr.
Water Type Type III
Configuration Benchtop
Process Double Pass RO system

Type II Water Purification System

This water purification system provides Type II level water with consistency and reliability. It removes approximately 98% of inorganic ions and 99 % of all dissolved organic substances

Output of Pure water &ge; 10 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 30 L
Output of Pure water &ge; 20 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 30 L
Output of Pure water &ge; 30 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 30 L