UV Water Purification System LUVW-B10

UV Water Purification System LUVW-B10 is a 30 L capacited revolutionary, modular design integrated with deionization cartridge, storage tank and UV sterilizer which helps in elimination of large amount of salts and other minerals from water using 2 stages of RO with TOC level of < 10 ppb. The highlight feature is the UV sterilizer which destroys the DNA of micro-org making the water contamination free. Here the concentrate or reject stream is fed into a second RO system to maximize water recovery. It’s designed to deliver compliant purified water with clear quality parameters and care free maintenance

Output of Pure water &ge; 10 L / hr.
Process Double Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Output of Ultrapure water &ge; 1- 1.5 L / min
Resistivity at 25 °C 18.25 M &Omega;. cm
Conductivity at 25 °C &le; 5 µs / cm
TOC < 10 ppb
Pyrogens / Endotoxins < 0.025 EU / ml
Bacteria < 1 cfu / ml
Particles ( > 0.22 µm ) < 1 / ml
Absorbance ( 254 nm ) &le; 0.001
Reactive Silica ( SiO2 ) < 0.01 ppm
Heavy metal < 0.01 ppm
Electrical requirements 220 V / 50 Hz
Power &gt; 150 W
Dimensions ( L x W x H ) 340 x 550 x 530 mm
Weight 41 kg
  • Advanced Double Pass reverse osmosis system for excellent water quality
  • 2 levels of water purification with high recovery rate
  • Online monitoring of water resistance
  • Inbuilt UV sterilizer
  • Equipped with 30 L water holding tank
  • Source of inlet water – Tap water
  • Benchtop / Floor Standing
  • Least TOC level < 3ppb
  • LCD display to monitor the intake of water pressure and various parameters intuitively
  • Programmed water shortage protection alarm
  • Anti-fouling RO membrane prevention programme
  • Integrated built in Deionization cartridge
  • Ease of cleansing , disinfecting and draining waste water
  • Micro filter membrane to filter out pollutants
  • Automatic RO membrane antiscale flushing to extend the life of the RO membrane

Related Products of UV Water Purification System

UV water purification systems destroy the DNA of micro-organisms making the water contamination free. Water produced from UV water purification is contamination free water which is potable for consumption

Output of Pure water &ge; 20 L / hr.
Process Double Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Output of Pure water &ge; 50 L / hr.
Process Single Pass RO system
Configuration Floor Standing
Water Tank capacity 80 L
Output of Pure water &ge; 20 L / hr.
Process Single Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Output of Pure water &ge; 30 L / hr.
Process Single Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Output of Pure water &ge; 10 L / hr.
Process Single Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Output of Pure water &ge; 40 L / hr.
Process Single Pass RO system
Configuration Floor Standing
Water Tank capacity 80 L
Output of Pure water &ge; 30 L / hr.
Process Double Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Output of Pure water &ge; 50 L / hr.
Process Double Pass RO system
Configuration Floor Standing
Water Tank capacity 80 L
Output of Pure water &ge; 40 L / hr.
Process Double Pass RO system
Configuration Floor standing
Water Tank capacity 80 L

Type II Water Purification System

This water purification system provides Type II level water with consistency and reliability. It removes approximately 98% of inorganic ions and 99 % of all dissolved organic substances

Output of Pure water &ge; 10 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 30 L
Output of Pure water &ge; 20 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 30 L
Output of Pure water &ge; 30 L / hr.
Process Double Pass RO system
Water Type Type II
Water Tank capacity 30 L
Output 30 liters/hour
Flow rate Up to 2 liters/minute (with pressure tank)
Pure water outlet 2 reverse osmosis water, deionized water
Deionized Water Quality Resistivity: 16 to 18.2 M Ω cm<br/> Bacteria: N/A<br/> Particle (>0.1 µm): N/A
Output 30 liters/hour
Flow rate Up to 2 liters/minute (with pressure tank)
Pure water outlet 2 reverse osmosis water, deionized water
Deionized Water Quality Resistivity: 16 to 18.2 M Ω cm<br/> Bacteria: N/A<br/> Particle (>0.1 µm): N/A

Type I and Type III Water Purification System

This water purification system is a combinational system that produces Type III water after RO and Type I water after deionization in one cycle

Output of Pure water &ge; 10 L / hr.
Water Type Type I and Type III
Water Tank capacity 30 L
Configuration Benchtop
Output of Pure water &ge; 30 L / hr.
Water Type Type I and Type III
Water Tank capacity 30 L
Configuration Benchtop
Output of Pure water &ge; 20 L / hr.
Water Type Type I and Type III
Water Tank capacity 30 L
Configuration Benchtop

UV Water Purification System

UV water purification systems destroy the DNA of micro-organisms making the water contamination free. Water produced from UV water purification is contamination free water which is potable for consumption

Output of Pure water &ge; 10 L / hr.
Process Double Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Output of Pure water &ge; 30 L / hr.
Process Double Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Output of Pure water &ge; 20 L / hr.
Process Double Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Water quality Two stage(Type III and type I)
Feed water Tap waterTDS≤400ppm<hr> Water temperature: 5-40℃<hr> Type 3 water ≥10L/h
Conectivity <5 μs/cm@25℃
Resistivity 18.25 MΩ.cm @ 25 ℃
Water quality One stage (Type I)
Feed water RO water /Distilled water<hr> Water temperature: 5 ~ 40℃
Resistivity 18.25 MΩ.cm @ 25 ℃
TOC < 5ppb
Output 2nd stage RO water 90 liters/hour
Output ultrapure water Up to 2 liters/minute (when tank is full)
Ultrapure Water Quality Resistivity (25°C) 18.2 M Ω cm<br/> TOC: < 3ppb<br/> Bacteria: <0.1 cfu/ml<br/> Particle (>0.2 µm): <1/ml<br/> Endotoxin: <0.001EU/ml<br/> RNases: <1pg/ml<br/> DNases: <5pg/ml
RO Water Quality Conductivity 1st stage RO water: Feed water Conductivity ×5 %<br/> Conductivity 2nd stage RO water: 1 to 5 µs/cm