Ozone Test Chamber LOC-A14

Ozone Test Chamber LOC-A14 is specifically designed to detect the concentration of ozone with the help of ozone detector. Along with low maintenance and noiseless generator this machine has a well-built corrosion resistant body.

Diameter of holder (mm) 900
Length of each side (mm) 460
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H
Temperature fluctuation ± 0.5 ℃
Speed rate for cooling Ambient ~ 0 ℃ within 20 min
Timing range 0 ~ 999 hours
Ozone concentration 1 ~ 1000PPHM
Sample holder rotate speed 0 ~ 10 r/min (adjustable)
Clamps tensile stretch 5 % ~ 35 %
Max. ozone concentration 120 g O<sub>3</sub>/m³
Ozone output 3.5 g O<sub>3</sub>/h (oxygen input, flow rate 100L/h)
Nominal power 11000 W
Internal dimensions 1000 × 1000 × 1000 mm
Overall dimensions (mm) 1500 × 1550 × 2110 mm
Power & voltage AC 380 V 50Hz
  • Use this static and dynamic combined sample holders
  • PID programmable controller with LED touch screen display
  • Equipped with UV detector to detect the concentration of ozone
  • Designed with combination of three control systems- PLC, HMI and SOC
  • Incorporated with protection module for safety voltage
  • Solid and durable structured closed-type compressor unit
  • User-friendly and reliable
  • Stable and require low maintenance
  • Consists of highly efficient low noise ozone generator
  • Made up of corrosion resistant stainless steel body

Applied to various industries such as automobile, rubber & plastics, packaging, medical equipment, colleges and universities, research laboratories etc.

Related Products of Ozone Test Chamber

Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.

Diameter of holder (mm) 700
Length of each side (mm) 350
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H
Diameter of holder (mm) 400
Length of each side (mm) 180
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H
Temperature fluctuation ± 0.5 ℃
Speed rate for cooling Ambient ~ 0 ℃ within 20 min
Diameter of holder (mm) 600
Length of each side (mm) 220
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H

UV Test Chamber

We manufacture UV test machine to simulate sunlight alongwith condenser and water spray system to simulate rain and dew. These chambers are used in various industries to detect the damage caused by environmental factors.

Temperature Range RT + 100 °C ~ 850 °C
Humidity range At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %
Testing Time 20 hours
Testing Voltage 120 V ~ 145 V (135 V)
UV Temperature 50 °C to 75 °C
Testing Capacity 48 piece (75 x 150 mm); 50 piece (75x 150 mm)
Weight 136 kg
Water Consumption Distilled water, 8liters per day
Temperature Range RT + 100 °C ~ 630 °C
Humidity range 30 % ~ 85 % RH
Testing Time 20 hours
Testing Voltage 120 V ~ 145 V

Drug Test Chamber

Drug test chambers are designed to conduct stability and shelf life studies on drug and drugs components.

Interior Volume 500 L
Heat load 1000 W
Temperature Range 0℃ to 100 ℃
Temperature Deviation in time ± 2.0 ℃
Interior Volume 100 L
Heat load 1000 W
Temperature Range 0℃ to 100 ℃
Temperature Deviation in time ± 2.0 ℃
Interior Volume 225 L
Heat load 1000 W
Temperature Range 0℃ to 100 ℃
Temperature Deviation in time ± 2.0 ℃

Xenon Test Chamber

We manufacture Xenon test chambers which consist of xenon lamp to simulate environmental factors to test its effect on products. It is widely used in research, product development and quality control.

Bandwidth Measurement (nm) 280 ~ 800
Specimen Capacity (pcs) 28
Specimen holder size (mm) 80 × 15
Chamber Temperature Range Ambient ~ 100 ℃ ± 2 °C
Temperature Range RT+50℃ to 70℃
Temperature Fluctuation ±3℃
Cooling Way Air-cooled
Raining Time 0-99min adjustable
Bandwidth Measurement (nm) 300 - 420
Specimen Capacity (pcs) 34
Specimen holder size (mm) 80 × 15
Chamber Temperature Range Ambient ~ 100 ℃ ± 2 °C

Sand Test Chamber

In order to increase the durability of product, we need to test its performance under various conditions. Keeping this in mind, Labtron presents sand test chambers which simulate dust and sand conditions in a controlled atmosphere.

Temperature range Ambient to + 50 ℃
Relative Humidity < 30 % RH
Normal wire diameter 50 um
Normal width of a gap between wire 75 um
Temperature range Ambient to + 50 ℃
Relative Humidity < 30 % RH
Normal wire diameter 50 um
Normal width of a gap between wire 75 um
Temperature range Ambient to + 50 ℃
Relative Humidity < 30 % RH
Normal wire diameter 50 um
Normal width of a gap between wire 75 um

Plant Growth Chamber

Labtron’s plant growth chamber is designed with accurate control of temperature, light, humidity, CO2 and other environmental factors which are necessary for plant growth. These chambers are helpful for researchers to carryout different experiments on plants without any dependency on climatic factors.

Chamber Volume 300 L
Shelves 3(PCS)
Display Resolution 0.1 ℃
Temperature Range Without Lighting: 0 to 50℃ <br/> With lighting:10 to 50℃
Chamber Volume 800 L
Shelves 3(PCS)
Display Resolution 0.1 ℃
Temperature Range Without Lighting: 0 to 50℃ <br/> With lighting:10 to 50℃
Chamber Volume 450 L
Shelves 3(PCS)
Display Resolution 0.1 ℃
Temperature Range Without Lighting: 0 to 50℃ <br/> With lighting:10 to 50℃