UV Test Chamber LUVC-A10

We deliver an excellent range of UV Test chambers, the model of LUVC-A10 features three types of UV lamps: UV-A lamp that can simulate sunlight from 365 nm to 295 nm cut-off wavelength, UV-B lamp that can simulate short wavelength UV radiation that reaches earth’s surface, UV-C lamp that can simulate UV sunlight through windows, this provides an accurate environment condition to give precise test results.

Temperature Range
Humidity range
Testing Time
Testing Voltage
Testing Current
Black Panel Temperature
Black Bulb Thermometer
Sample Rack Size
Sample Rack Rotation Speed
Specimens capacity
Specimen Sample Rack
UV wavelength
UV Temperature 50 °C to 75 °C
Testing Capacity 48 piece (75 x 150 mm); 50 piece (75x 150 mm)
Irradiance Control
Irradiation Source
Weight 136 kg
Water Spray
Water Consumption Distilled water, 8liters per day
Distance of Specimen and lamp
Internal dimensions
Overall dimensions
Dimension(W x D x H) 137 x 53 x 136 cm
Nominal power
Power 1ψ, 120 V / 60 Hz, 16 A or 230 V / 50 Hz, 9 A, 1800 W(max)
  • Designed to perform UV light testing with the help of UV lamps
  • Provision to choose among different wavelengths of UV light
  • Three types of UV lamps: UV-A lamp can simulate sunlight from 365 nm to 295 nm cut-off wavelength, UV-B lamp can simulate short wavelength UV radiation that reaches earth’s surface, UV-C lamp can simulate UV sunlight through windows
  • Light and temperature can be controlled through an user friendly coloured touch screen
  • Light intensity control system allow users to set different test light intensity based on test requirements

The UV Test Chamber is widely used in plastics, printing and packaging, paint, resins, adhesives, automotive, cosmetics, metals, electroplating, medicine, etc.

Related Products of UV Test Chamber

We manufacture UV test machine to simulate sunlight alongwith condenser and water spray system to simulate rain and dew. These chambers are used in various industries to detect the damage caused by environmental factors.

Temperature Range RT + 100 °C ~ 630 °C
Humidity range 30 % ~ 85 % RH
Testing Time 20 hours
Testing Voltage 120 V ~ 145 V
Temperature Range RT + 100 °C ~ 850 °C
Humidity range At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %
Testing Time 20 hours
Testing Voltage 120 V ~ 145 V (135 V)

Plant Growth Chamber

Labtron’s plant growth chamber is designed with accurate control of temperature, light, humidity, CO2 and other environmental factors which are necessary for plant growth. These chambers are helpful for researchers to carryout different experiments on plants without any dependency on climatic factors.

Chamber Volume 800 L
Shelves 3(PCS)
Display Resolution 0.1 ℃
Temperature Range Without Lighting: 0 to 50℃ <br/> With lighting:10 to 50℃
Chamber Volume 300 L
Shelves 3(PCS)
Display Resolution 0.1 ℃
Temperature Range Without Lighting: 0 to 50℃ <br/> With lighting:10 to 50℃
Chamber Volume 450 L
Shelves 3(PCS)
Display Resolution 0.1 ℃
Temperature Range Without Lighting: 0 to 50℃ <br/> With lighting:10 to 50℃

Sand Test Chamber

In order to increase the durability of product, we need to test its performance under various conditions. Keeping this in mind, Labtron presents sand test chambers which simulate dust and sand conditions in a controlled atmosphere.

Temperature range Ambient to + 50 ℃
Relative Humidity < 30 % RH
Normal wire diameter 50 um
Normal width of a gap between wire 75 um
Temperature range Ambient to + 50 ℃
Relative Humidity < 30 % RH
Normal wire diameter 50 um
Normal width of a gap between wire 75 um
Temperature range Ambient to + 50 ℃
Relative Humidity < 30 % RH
Normal wire diameter 50 um
Normal width of a gap between wire 75 um

Xenon Test Chamber

We manufacture Xenon test chambers which consist of xenon lamp to simulate environmental factors to test its effect on products. It is widely used in research, product development and quality control.

Temperature Range RT+50℃ to 70℃
Temperature Fluctuation ±3℃
Cooling Way Air-cooled
Raining Time 0-99min adjustable
Bandwidth Measurement (nm) 300 - 420
Specimen Capacity (pcs) 34
Specimen holder size (mm) 80 × 15
Chamber Temperature Range Ambient ~ 100 ℃ ± 2 °C
Bandwidth Measurement (nm) 280 ~ 800
Specimen Capacity (pcs) 28
Specimen holder size (mm) 80 × 15
Chamber Temperature Range Ambient ~ 100 ℃ ± 2 °C

Drug Test Chamber

Drug test chambers are designed to conduct stability and shelf life studies on drug and drugs components.

Interior Volume 100 L
Heat load 1000 W
Temperature Range 0℃ to 100 ℃
Temperature Deviation in time ± 2.0 ℃
Interior Volume 500 L
Heat load 1000 W
Temperature Range 0℃ to 100 ℃
Temperature Deviation in time ± 2.0 ℃
Interior Volume 225 L
Heat load 1000 W
Temperature Range 0℃ to 100 ℃
Temperature Deviation in time ± 2.0 ℃

Temperature and Humidity Test Chamber

Labtron offers temperature and humidity test chambers which are used in various industries to test large equipments such as automotive parts by controlling the temperature and humidity. It is highly stable and provides enough space to work.

Capacity 50 L
Temperature range (- 20 °C) to 150 °C
Low type I – 40 °C, II – 70 °C
Environmental condition 5 ℃ ~ + 40 ℃ ≤ 85 % RH
Capacity 100 L
Temperature range (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃
Temperature cooling rate 1 ℃ / min
Overall dimension (D x W x H) 860 x 1050 x 1620 mm
Capacity 80 L
Temperature range (- 20 °C) to 150 °C
Low type I – 40 °C, II – 70 °C