Xenon Test Chamber LXC-A22

Xenon Test Chamber LXC-A22 is a benchtop model with single xenon arc lamp and is available with optional automatic water supply. A large spectrum of environmental condition based test materials can be tested using this model.

Temperature Range RT+50℃ to 70℃
Temperature Fluctuation ±3℃
Cooling Way Air-cooled
Raining Time 0-99min adjustable
Irradiation Strength 400-700w/m2
Wavelength 290-800nm
Dimming Range 5%-100%
Lamp Power 2.5kW
Total Power 4.5kW
Power Supply AC380V±10% 50±0.5Hz (three-phase five wire system)
Interior Size(W×D×H) 500×320×300mm
Exterior Size(W×D×H) 900×800×750mm
Standard Configurations Stainless steel sample holder, one air-cooled xenon lamp, one portable irradiation meter
  • Microcomputer PID temperature controller
  • PT100 platinum resistance thermometer as temperature sensor
  • Temperature auto-monitoring
  • Possess function of automatic calculus
  • Air cooled xenon arc lamp as light source
  • Has hand-held irradiator meter
  • Outer case made up of high quality A3 color plates through CNC machine surface sprayed with plastics
  • Inner case made up of SUS304 high-grade stainless steel
  • Contact-less heating through SSR(Solid State Relay)
  • Over temperature, leakage, short circuit protection, overload short circuit protection, lack of water protector, alarms

It is used in different industries such as plastic, paint, dyeing, automobile, motorcycle, petrochemical, textile, leather products etc.

Related Products of Xenon Test Chamber

We manufacture Xenon test chambers which consist of xenon lamp to simulate environmental factors to test its effect on products. It is widely used in research, product development and quality control.

Bandwidth Measurement (nm) 300 - 420
Specimen Capacity (pcs) 34
Specimen holder size (mm) 80 × 15
Chamber Temperature Range Ambient ~ 100 ℃ ± 2 °C
Bandwidth Measurement (nm) 300 - 420
Specimen Capacity (pcs) 34
Specimen holder size (mm) 80 × 15
Chamber Temperature Range Ambient ~ 100 ℃ ± 2 °C
Bandwidth Measurement (nm) 280 ~ 800
Specimen Capacity (pcs) 28
Specimen holder size (mm) 80 × 15
Chamber Temperature Range Ambient ~ 100 ℃ ± 2 °C
Bandwidth Measurement (nm) 280 ~ 800
Specimen Capacity (pcs) 28
Specimen holder size (mm) 80 × 15
Chamber Temperature Range Ambient ~ 100 ℃ ± 2 °C

Xenon Test Chamber

We manufacture Xenon test chambers which consist of xenon lamp to simulate environmental factors to test its effect on products. It is widely used in research, product development and quality control.

Bandwidth Measurement (nm) 280 ~ 800
Specimen Capacity (pcs) 28
Specimen holder size (mm) 80 × 15
Chamber Temperature Range Ambient ~ 100 ℃ ± 2 °C
Bandwidth Measurement (nm) 300 - 420
Specimen Capacity (pcs) 34
Specimen holder size (mm) 80 × 15
Chamber Temperature Range Ambient ~ 100 ℃ ± 2 °C
Temperature Range RT+50℃ to 70℃
Temperature Fluctuation ±3℃
Cooling Way Air-cooled
Raining Time 0-99min adjustable

Plant Growth Chamber

Labtron’s plant growth chamber is designed with accurate control of temperature, light, humidity, CO2 and other environmental factors which are necessary for plant growth. These chambers are helpful for researchers to carryout different experiments on plants without any dependency on climatic factors.

Chamber Volume 300 L
Shelves 3(PCS)
Display Resolution 0.1 ℃
Temperature Range Without Lighting: 0 to 50℃ <br/> With lighting:10 to 50℃
Chamber Volume 800 L
Shelves 3(PCS)
Display Resolution 0.1 ℃
Temperature Range Without Lighting: 0 to 50℃ <br/> With lighting:10 to 50℃
Chamber Volume 450 L
Shelves 3(PCS)
Display Resolution 0.1 ℃
Temperature Range Without Lighting: 0 to 50℃ <br/> With lighting:10 to 50℃

Sand Test Chamber

In order to increase the durability of product, we need to test its performance under various conditions. Keeping this in mind, Labtron presents sand test chambers which simulate dust and sand conditions in a controlled atmosphere.

Temperature range Ambient to + 50 ℃
Relative Humidity < 30 % RH
Normal wire diameter 50 um
Normal width of a gap between wire 75 um
Temperature range Ambient to + 50 ℃
Relative Humidity < 30 % RH
Normal wire diameter 50 um
Normal width of a gap between wire 75 um
Temperature range Ambient to + 50 ℃
Relative Humidity < 30 % RH
Normal wire diameter 50 um
Normal width of a gap between wire 75 um

Ozone Test Chamber

Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.

Diameter of holder (mm) 600
Length of each side (mm) 220
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H
Diameter of holder (mm) 400
Length of each side (mm) 180
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H
Temperature fluctuation ± 0.5 ℃
Speed rate for cooling Ambient ~ 0 ℃ within 20 min

UV Test Chamber

We manufacture UV test machine to simulate sunlight alongwith condenser and water spray system to simulate rain and dew. These chambers are used in various industries to detect the damage caused by environmental factors.

UV Temperature 50 °C to 75 °C
Testing Capacity 48 piece (75 x 150 mm); 50 piece (75x 150 mm)
Weight 136 kg
Water Consumption Distilled water, 8liters per day
Temperature Range RT + 100 °C ~ 630 °C
Humidity range 30 % ~ 85 % RH
Testing Time 20 hours
Testing Voltage 120 V ~ 145 V
Temperature Range RT + 100 °C ~ 850 °C
Humidity range At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %
Testing Time 20 hours
Testing Voltage 120 V ~ 145 V (135 V)