Ozone Test Chamber LOC-A13

Ozone Test Chamber LOC-A13 is specifically designed to detect the concentration of ozone with the help of ozone detector. Along with low maintenance and noiseless generator this machine has a well-built corrosion resistant body.

Diameter of holder (mm) 700
Length of each side (mm) 350
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H
Temperature fluctuation ± 0.5 ℃
Speed rate for cooling Ambient ~ 0 ℃ within 20 min
Timing range 0 ~ 999 hours
Ozone concentration 1 ~ 1000PPHM
Sample holder rotate speed 0 ~ 10 r/min (adjustable)
Clamps tensile stretch 5 % ~ 35 %
Max. ozone concentration 120 g O<sub>3</sub>/m³
Ozone output 3.5 g O<sub>3</sub>/h (oxygen input, flow rate 100L/h)
Nominal power 9000 W
Internal dimensions 800 × 1000 × 1000 mm
Overall dimensions (mm) 1280 × 1550 × 2110 mm
Power & voltage AC 380 V 50Hz
  • Use this static and dynamic combined sample holders
  • PID programmable controller with LED touch screen display
  • Equipped with UV detector to detect the concentration of ozone
  • Designed with combination of three control systems- PLC, HMI and SOC
  • Incorporated with protection module for safety voltage
  • Solid and durable structured closed-type compressor unit
  • User-friendly and reliable
  • Stable and require low maintenance
  • Consists of highly efficient low noise ozone generator
  • Made up of corrosion resistant stainless steel body

Applied to various industries such as automobile, rubber & plastics, packaging, medical equipment, colleges and universities, research laboratories etc.

Related Products of Ozone Test Chamber

Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.

Diameter of holder (mm) 900
Length of each side (mm) 460
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H
Diameter of holder (mm) 600
Length of each side (mm) 220
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H
Diameter of holder (mm) 400
Length of each side (mm) 180
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H
Temperature fluctuation ± 0.5 ℃
Speed rate for cooling Ambient ~ 0 ℃ within 20 min

UV Test Chamber

We manufacture UV test machine to simulate sunlight alongwith condenser and water spray system to simulate rain and dew. These chambers are used in various industries to detect the damage caused by environmental factors.

Temperature Range RT + 100 °C ~ 630 °C
Humidity range 30 % ~ 85 % RH
Testing Time 20 hours
Testing Voltage 120 V ~ 145 V
Temperature Range RT + 100 °C ~ 850 °C
Humidity range At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %
Testing Time 20 hours
Testing Voltage 120 V ~ 145 V (135 V)
UV Temperature 50 °C to 75 °C
Testing Capacity 48 piece (75 x 150 mm); 50 piece (75x 150 mm)
Weight 136 kg
Water Consumption Distilled water, 8liters per day

Xenon Test Chamber

We manufacture Xenon test chambers which consist of xenon lamp to simulate environmental factors to test its effect on products. It is widely used in research, product development and quality control.

Bandwidth Measurement (nm) 300 - 420
Specimen Capacity (pcs) 34
Specimen holder size (mm) 80 × 15
Chamber Temperature Range Ambient ~ 100 ℃ ± 2 °C
Bandwidth Measurement (nm) 280 ~ 800
Specimen Capacity (pcs) 28
Specimen holder size (mm) 80 × 15
Chamber Temperature Range Ambient ~ 100 ℃ ± 2 °C
Temperature Range RT+50℃ to 70℃
Temperature Fluctuation ±3℃
Cooling Way Air-cooled
Raining Time 0-99min adjustable

Salt Spray Test Chamber

Labtron offers wide range of salt spray corrosion test systems with ability to test the corrosive resistant of products. Our user friendly products suit our clients' requirement and hence, continue to be in demand.

Testing room capacity 410 L
Temperature range Ambient to +60°C
Humidity range 95 to 98% RH
Temperature Fluctuation ± 0.5 ℃
Testing room capacity 110 L
Temperature range Ambient to +60°C
Humidity range 95 to 98% RH
Temperature Fluctuation ± 0.5 ℃
Testing room capacity 326 L
Temperature range Ambient to +60°C
Humidity range 95 to 98% RH
Temperature Fluctuation ± 0.5 ℃

Drug Test Chamber

Drug test chambers are designed to conduct stability and shelf life studies on drug and drugs components.

Interior Volume 500 L
Heat load 1000 W
Temperature Range 0℃ to 100 ℃
Temperature Deviation in time ± 2.0 ℃
Interior Volume 225 L
Heat load 1000 W
Temperature Range 0℃ to 100 ℃
Temperature Deviation in time ± 2.0 ℃
Interior Volume 100 L
Heat load 1000 W
Temperature Range 0℃ to 100 ℃
Temperature Deviation in time ± 2.0 ℃

Ozone Test Chamber

Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.

Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H
Temperature fluctuation ± 0.5 ℃
Speed rate for cooling Ambient ~ 0 ℃ within 20 min
Diameter of holder (mm) 400
Length of each side (mm) 180
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H
Diameter of holder (mm) 600
Length of each side (mm) 220
Temperature range 0℃ ~ 100℃
Humidity range 30 % - 98 % R.H