Gel Card Incubator LIGC-A10

Gel Card Incubator LIGC-A10 is a microprocessor controlled compact and tabletop unit, offers RT+5 to 60°C of temperature range with 1 to 9999 min of time range. Features 24 card capacity with heating time of 10 and 25 minutes for 30 to 37°C/60°C respectively. Designed with powder coated steel shell and LCD display, is equipped with automatic fault detection and alarm function and supports temperature deviation calibration function.

Capacity 24 cards
Temperature range RT+5°C to 60°C
Temperature accuracy ± 0.5°C
Temperature precision 0.1°C
Time range 1 to 9999 min/continuous operation
Heating time ≤25 min (30 to 60°C)<br/> ≤10 min (30 to 37°C)
Controller PID microprocessor
Display LCD
Housing Powder coated steel
Power supply 220/110 V, 50/60 Hz
Dimension (W×D×H) 370×290×145 mm
Package dimension (W×D×H) 450×330×330 mm
Net weight 7.5 kg
Gross weight 8.5 kg
  • A microprocessor controlled compact and tabletop unit, convenient and easy operation
  • RT+5 to 60°C of temperature range with 1 to 9999 min of time range, flexible operation
  • 24 card capacity with heating time of 10 and 25 minutes for 30 to 37°C/60°C respectively
  • Powder coated steel shell, durable, easy-to-clean and low maintenance required
  • LCD display, convenient setting and monitoring of different running parameters
  • Automatic fault detection and alarm function, safe and reliable operation
  • Temperature deviation calibration function, reproducible and reliable results
  • High-efficient, stable and high-performance unit with independent incubation zones

Gel Card incubator is used across life sciences including immunology and biotechnology, microbiology, cell and molecular biology, laboratories and factories.

Temperature range RT. 5°C ~ 130°C
Temperature accuracy ± 0.5 °C at 40 °C ; ± 1 °C at 120°C
Temperature uniformity ± 0.5 °C
Block quantity 4
Temperature range RT. 5°C ~ 100°C
Temperature accuracy ≤ ± 0.3°C
Temperature uniformity ≤ ± 0.3 °C
Temperature stability ± 0.3°C
Temperature range RT. 5°C ~ 160°C
Temperature accuracy ± 0.5 °C at 40 °C ; ± 1 °C at 120°C
Temperature uniformity ± 0.5 °C
Block quantity 1 or 2
Capacity 250 L
Illumination type 2 side illumination
Light source Fluorescent lamp
Lighting illumination 0 to 12000 lx
Capacity 450 L
Illumination type 2 side illumination
Light source Fluorescent lamp
Lighting illumination 0 to 20000 lx
Capacity 350 L
Illumination type 2 side illumination
Light source Fluorescent lamp
Lighting illumination 0 to 15000 lx
Capacity 250 L
Temperature range 0 to 60°C
Accuracy ± 0.5°C
Ambient temperature 0 to 60°C
Capacity 150 L
Temperature range 0 to 60°C
Accuracy ± 0.5°C
Ambient temperature 0 to 60°C
Capacity 100 L
Temperature range 0 to 60°C
Accuracy ± 0.5°C
Ambient temperature 0 to 60°C

Cooling Incubator

This wide range of cooling incubators is available in different temperature ranges and it is suitable to serve for preservation of culture medium, serum, medicine as well as micro-organism training and environmental testing, etc.

Shelves 3(pcs)
Display Resolution 0.1 ℃
Temperature Range (-20) ℃ ~ 65 ℃
Temperature Stability High: ± 0.5 ℃ Low: ± 1 ℃
Shelves 3(pcs)
Display Resolution 0.1 ℃
Temperature Range (-10) ℃ ~ 65 ℃
Temperature Stability High: ± 0.5 ℃ Low: ± 1 ℃
Shelves 3(pcs)
Display Resolution 0.1 ℃
Temperature Range (-40) ℃ ~ 65 ℃
Temperature Stability High: ± 0.5 ℃ Low: ± 1 ℃
Control System Microprocessor control system + Siemens PLC
Display LCD display with touch screen control panel
Time for creating anaerobic state in sample chamber < 5 minutes
Time for creating anaerobic state in operation chamber < 1 hr
Time for creating anaerobic state in sample chamber < 5 min
Time for creating anaerobic state in operation chamber < 1 hour (Oxygen concentration ≤ 1 %)
Anaerobic environment maintenance time > 12 h (when no supply of mixed gas)
Range of temperature control in incubation chamber RT + 3°C to 60°C
Control System Microcomputer control system
Display LCD display with button-press keypad
Time for creating anaerobic state in sample chamber < 5 minutes
Time for creating anaerobic state in operation chamber < 1hr