Dry bath incubator LDBI-A10

Dry bath incubator LDBI-A10 is a precise, reliable and easy-to-use product that uses high purity aluminum as a heat conduction medium. It is fitted with a microprocessor controlled system along with digital temperature display, buzzer alarm function and in-built over temperature protection device. In addition, it has a wide temperature range and is available in single, dual and four block models.

Temperature range RT. 5°C ~ 160°C
Temperature control range
Temperature setting range
Temperature accuracy ± 0.5 °C at 40 °C ; ± 1 °C at 120°C
Temperature uniformity ± 0.5 °C
Temperature stability
Block quantity 1 or 2
Heating time ≤ 15 min (25 °C ~ 160 °C)
Cooling time
Display accuracy ± 0.1 °C
Time range 1 min - 99 hr. 59 min
Auto warming
Auto running
Auto heating
Auto resume to run
Multi points running
Multi points running circularly
Voltage AC 220 V / 110 V (Optional)
Power 300 W
Fuse
Dimension (L x W x H) 260 x 220 x 100 mm
Net weight 5 kg
Gross Weight 5.5 kg
  • Microprocessor controlled system
  • High purity aluminum as a heat conduction medium instead of traditional water bath device
  • Real time temperature display
  • Mechanized fault detection and buzzer alarm function
  • Uncomplicated cleaning, replacement and disinfection of blocks
  • In-built over temperature protection device
  • More reliable to use with two redundant hardware circuit design
  • Wide temperature range
  • Highly precise
  • User-friendly
  • 12-months warranty
Model Diameter of test tube No. of test tubes
DBA-01 6 mm 48
DBA-02 7 mm 48
DBA-03 10 mm 24
DBA-04 12 mm 24
DBA-05 13 mm 24
DBA-06 15 mm 16
DBA-07 16 mm 16
DBA-08 19 mm 12
DBA-09 20 mm 12
DBA-10 26 mm 8
DBA-11 28 mm 4
DBA-12 40 mm 3
DBA-13 0.2 ml centrifuge tube 48
DBA-14 0.5 ml centrifuge tube 48
DBA-15 1.5 ml centrifuge tube 24
DBA-16 2.0 ml centrifuge tube 24
DBA-17 0.2 ml well micro plate 96

Dry bath incubators can be used for sample preparation, electrophoresis gel degeneration etc. They also find wide applicability in fields like molecular biology, microbiology, biochemistry and genetics.

Temperature range RT. 5°C ~ 130°C
Temperature accuracy ± 0.5 °C at 40 °C ; ± 1 °C at 120°C
Temperature uniformity ± 0.5 °C
Block quantity 4
Temperature range RT. 5°C ~ 100°C
Temperature accuracy ≤ ± 0.3°C
Temperature uniformity ≤ ± 0.3 °C
Temperature stability ± 0.3°C
Temperature control range RT. (-30) °C - 100°C
Temperature setting range (-10) ℃ - 100 ℃
Temperature accuracy ≤ ± 0.3 °C
Temperature uniformity ≤ ± 0.3 °C
Temperature range RT. 5°C ~ 100°C
Temperature setting range 0 °C - 100 °C
Temperature accuracy ≤ ± 0.3 °C
Temperature uniformity ≤ ± 0.3 °C
Capacity 250 L
Illumination type 3-side illumination
Illumination source Fluorescent lamp
Lighting illumination 0 to 12000 lx
Capacity 450 L
Illumination type 3-side illumination
Illumination source Fluorescent lamp
Lighting illumination 0 to 20000 lx
Capacity 350 L
Illumination type 3-side illumination
Illumination source Fluorescent lamp
Lighting illumination 0 to 20000 lx
Capacity 24 cards
Temperature range RT+5°C to 60°C
Temperature accuracy ± 0.5°C
Temperature precision 0.1°C
Time for creating anaerobic state in sample chamber < 5 min
Time for creating anaerobic state in operation chamber < 1 hour (Oxygen concentration ≤ 1 %)
Anaerobic environment maintenance time > 12 h (when no supply of mixed gas)
Range of temperature control in incubation chamber RT + 3°C to 60°C
Control System Microprocessor control system + Siemens PLC
Display LCD display with touch screen control panel
Time for creating anaerobic state in sample chamber < 5 minutes
Time for creating anaerobic state in operation chamber < 1 hr
Control System Microcomputer control system
Display LCD display with button-press keypad
Time for creating anaerobic state in sample chamber < 5 minutes
Time for creating anaerobic state in operation chamber < 1hr
Capacity 100 L
Temperature range 0 to 60°C
Accuracy ± 0.5°C
Ambient temperature 0 to 60°C
Capacity 150 L
Temperature range 0 to 60°C
Accuracy ± 0.5°C
Ambient temperature 0 to 60°C
Capacity 250 L
Temperature range 0 to 60°C
Accuracy ± 0.5°C
Ambient temperature 0 to 60°C
Temperature range 5 to 60°C
Temperature uniformity ±0.5°C (ambient temperature 25°C, set value 37°C, 5 % no load)
Temperature fluctuation ±0.2°C (ambient temperature 25°C, set value 37°C, 5 % no load)
CO<sub>2</sub> Concentration range 0 to 20 %