It incorporates advantage of both closed and shaking incubation required for no. of processes which includes tissue culture, enzyme reaction, fermentation etc. It is highly efficient with user-friendly operation.
| Shaking Speed Range | 40 to 300 rpm |
| Platform Size | 280 × 220 mm |
| Display Resolution | 0.1 ℃ |
| Temperature Range | Room temperature +5 ℃ to 50 ℃ |
| Display | LCD |
| Circulation Mode | Forced convection |
| Shaking Mode | Rotatory Shaking |
| Drive Mode | Unishaft drive |
| Display | LCD |
| Circulation Mode | Forced convection |
| Shaking Mode | Rotatory Shaking |
| Drive Mode | Unishaft drive |
| Capacity | 250 L |
| Illumination type | 2 side illumination |
| Light source | Fluorescent lamp |
| Lighting illumination | 0 to 12000 lx |
| Capacity | 350 L |
| Illumination type | 2 side illumination |
| Light source | Fluorescent lamp |
| Lighting illumination | 0 to 15000 lx |
| Capacity | 450 L |
| Illumination type | 2 side illumination |
| Light source | Fluorescent lamp |
| Lighting illumination | 0 to 20000 lx |
This wide range of cooling incubators is available in different temperature ranges and it is suitable to serve for preservation of culture medium, serum, medicine as well as micro-organism training and environmental testing, etc.
| Shelves | 3(pcs) |
| Display Resolution | 0.1 ℃ |
| Temperature Range | (-40) ℃ ~ 65 ℃ |
| Temperature Stability | High: ± 0.5 ℃ Low: ± 1 ℃ |
| Shelves | 3(pcs) |
| Display Resolution | 0.1 ℃ |
| Temperature Range | (-10) ℃ ~ 65 ℃ |
| Temperature Stability | High: ± 0.5 ℃ Low: ± 1 ℃ |
| Shelves | 3(pcs) |
| Display Resolution | 0.1 ℃ |
| Temperature Range | (-20) ℃ ~ 65 ℃ |
| Temperature Stability | High: ± 0.5 ℃ Low: ± 1 ℃ |
| Control System | Microcomputer control system |
| Display | LCD display with button-press keypad |
| Time for creating anaerobic state in sample chamber | < 5 minutes |
| Time for creating anaerobic state in operation chamber | < 1hr |
| Control System | Microprocessor control system + Siemens PLC |
| Display | LCD display with touch screen control panel |
| Time for creating anaerobic state in sample chamber | < 5 minutes |
| Time for creating anaerobic state in operation chamber | < 1 hr |
| Time for creating anaerobic state in sample chamber | < 5 min |
| Time for creating anaerobic state in operation chamber | < 1 hour (Oxygen concentration ≤ 1 %) |
| Anaerobic environment maintenance time | > 12 h (when no supply of mixed gas) |
| Range of temperature control in incubation chamber | RT + 3°C to 60°C |
| Capacity | 450 L |
| Illumination type | 3-side illumination |
| Illumination source | Fluorescent lamp |
| Lighting illumination | 0 to 20000 lx |
| Capacity | 350 L |
| Illumination type | 3-side illumination |
| Illumination source | Fluorescent lamp |
| Lighting illumination | 0 to 20000 lx |
| Capacity | 250 L |
| Illumination type | 3-side illumination |
| Illumination source | Fluorescent lamp |
| Lighting illumination | 0 to 12000 lx |