Heating Incubator LHI-A15

Heating incubators LHI-A15 comes with polished stainless-steel chamber. Designed with inner glass door, helps in observing changes occurring in the specimen kept inside during incubation. Heating incubators are equipped with microprocessor-based PID controller for timing functions and controlling temperature parameter. It delivers a higher level of performance for storage of mould and biological cultivations.

Chamber Volume 270 L
Shelves 2 (pcs)
Display Resolution 0.1 ℃ / ± 0.5 ℃
Temperature Range RT 5 ℃ ~ 65 ℃
Temperature Stability
Temperature Uniformity
Ambient Temperature 5 ℃ ~ 35 ℃
Timing Range 1 ~ 9999 min
Interior Dimension (W × D × H) 600 × 600 × 750 mm
Exterior Dimension (W × D × H) 890 × 740 × 910 mm
Power consumption 700 W
Power 220 V, 50 Hz
  • Microprocessor-based PID controller with timing function
  • Equipped with inner glass door for easy operation
  • Separate temperature-limiting alarm system for safe usage
  • Options such as Printer connector and RS485 connector are available to connect printer and computer for data recording
Intelligent programmable temperature controller
Printer
Independent temperature-limiting Alarm system
RS485 connector

Heating incubators have useful scientific & research applications in agricultural, biological and other research departments.

Related Products of Heating Incubator

Equipped with inner glass door for easy operation, our heating incubators deliver a higher level of performance for storage and cultivation purpose. This range is available in different chamber volume.

Chamber Volume 80 L
Shelves 2 (pcs)
Display Resolution 0.1 ℃ / ± 0.5 ℃
Temperature Range RT 5 ℃ ~ 65 ℃
Chamber Volume 620 L
Shelves 4 (pcs)
Display Resolution 0.1 ℃ / ± 0.5 ℃
Temperature Range RT 5 ℃ ~ 65 ℃
Chamber Volume 16 L
Shelves 2 (pcs)
Display Resolution 0.1 ℃ / ± 0.5 ℃
Temperature Range RT 5 ℃ ~ 65 ℃
Chamber Volume 160 L
Shelves 2 (pcs)
Display Resolution 0.1 ℃ / ± 0.5 ℃
Temperature Range RT 5 ℃ ~ 65 ℃
Chamber Volume 420 L
Shelves 3 (pcs)
Display Resolution 0.1 ℃ / ± 0.5 ℃
Temperature Range RT 5 ℃ ~ 65 ℃
Chamber Volume 190 L
Shelves 2 (pcs)
Display Resolution 0.1 ℃ / + 0.2 ℃
Temperature Range RT 5 ℃ ~ 80 ℃
Chamber Volume 300 L
Shelves 2 (pcs)
Display Resolution 0.1 ℃ / + 0.2 ℃
Temperature Range RT 5 ℃ ~ 80 ℃
Chamber Volume 81 L
Shelves 2 (pcs)
Display Resolution 0.1 ℃ / + 0.2 ℃
Temperature Range RT 5 ℃ ~ 80 ℃
Chamber Volume 35 L
Shelves 2 (pcs)
Display Resolution 0.1 ℃ / ± 0.5 ℃
Temperature Range RT 5 ℃ ~ 65 ℃
Chamber Volume 50 L
Shelves 2 (pcs)
Display Resolution 0.1 ℃ / ± 0.5 ℃
Temperature Range RT 5 ℃ ~ 65 ℃
Chamber Volume 45 L
Shelves 2 (pcs)
Display Resolution 0.1 ℃ / + 0.2 ℃
Temperature Range RT 5 ℃ ~ 80 ℃

Shaking Incubator

It incorporates advantage of both closed and shaking incubation required for no. of processes which includes tissue culture, enzyme reaction, fermentation etc. It is highly efficient with user-friendly operation.

Display LCD
Circulation Mode Forced convection
Shaking Mode Rotatory Shaking
Drive Mode Unishaft drive
Shaking Speed Range 40 to 300 rpm
Platform Size 280 × 220 mm
Display Resolution 0.1 ℃
Temperature Range Room temperature +5 ℃ to 50 ℃
Display LCD
Circulation Mode Forced convection
Shaking Mode Rotatory Shaking
Drive Mode Unishaft drive
Capacity 150 L
Temperature range 0 to 60°C
Accuracy ± 0.5°C
Ambient temperature 0 to 60°C
Capacity 250 L
Temperature range 0 to 60°C
Accuracy ± 0.5°C
Ambient temperature 0 to 60°C
Capacity 100 L
Temperature range 0 to 60°C
Accuracy ± 0.5°C
Ambient temperature 0 to 60°C
Capacity 24 cards
Temperature range RT+5°C to 60°C
Temperature accuracy ± 0.5°C
Temperature precision 0.1°C
Air cycle Mode Gravity air convection
Function
Temperature range RT +5 to 50 ℃
Temperature resolution ratio 0.1 ℃
Temperature motion ± 0.5 ℃
Temperature uniformity ± 1.5 ℃
Body structure
Inner chamber Mirror stainless steel
Outer shell Cold rolling steel electrostatic spraying exterior
Insulation layer 6.5 cm polyurethane interlayer
Heater Nickel and chromium alloy heating wire
Controller
Temperature controller PID Intelligent
Temperature setting mode Touch button setting
Display mode LED
Time setting range 0 to 9999 min
Operation function Fixed temperature operation, Timing function, Auto stop
Additional function Sensor deviation correction, Temperature overshoot self-tuning, Internal parameter locking, Power-off parameter memory
Sensor CU50
Air cycle Mode Natural air convection
Function
Temperature range RT +5 to 250℃
Temperature resolution ratio 1 ℃
Temperature motion ± 1.0 ℃
Temperature uniformity ± 1.5 ℃
Body structure
Inner chamber Stainless steel
Outer shell Galvanized steel
Insulation layer Polyurethane interlayer
Heater Explosion proof alloy heating wire
Controller
Temperature controller PID Intelligent
Temperature setting mode Touch button setting
Display mode HD bright LED
Time setting range 0 to 9999 min
Operation function Fixed temperature operation, Timing function, Auto stop
Additional function Sensor deviation correction, Temperature overshoot self-tuning, Internal parameter locking, Power-off parameter memory
Sensor Temperature and humidity sensor
Air cycle Mode Natural air convection
Function
Temperature range RT +5 to 80 ℃
Temperature resolution ratio 1 ℃
Temperature motion ± 1.0 ℃
Temperature uniformity ± 1.5 ℃
Body structure
Inner chamber Stainless steel
Outer shell Galvanized steel
Insulation layer Polyurethane interlayer
Heater Explosion proof alloy heating wire
Controller
Temperature controller PID Intelligent
Temperature setting mode Touch button setting
Display mode HD bright LED
Time setting range 0 to 9999 min
Operation function Fixed temperature operation, Timing function, Auto stop
Additional function Sensor deviation correction, Temperature overshoot self-tuning, Internal parameter locking, Power-off parameter memory
Sensor Temperature and humidity sensor
Temperature range RT. 5°C ~ 100°C
Temperature accuracy ≤ ± 0.3°C
Temperature uniformity ≤ ± 0.3 °C
Temperature stability ± 0.3°C
Temperature range RT. 5°C ~ 160°C
Temperature accuracy ± 0.5 °C at 40 °C ; ± 1 °C at 120°C
Temperature uniformity ± 0.5 °C
Block quantity 1 or 2
Temperature range RT. 5°C ~ 130°C
Temperature accuracy ± 0.5 °C at 40 °C ; ± 1 °C at 120°C
Temperature uniformity ± 0.5 °C