Gasoline Oxidation Stability Tester LOST-D13

Gasoline Oxidation Stability Tester LOST-D13 is a compact, desktop instrument. Features integrated design having test part and control part united as one, bomb assembly as unit body design and oxygen bomb location hole design makes it convenient for operation. Equipped with built-in IPC, automation work mode, 10.1 inch color touch LCD display, Windows operation system ensures good outlook and convenient operating. Designed with double holes for parallel testing, heat preservation system for energy saving and high automatic software for hassle free running, metal bath without water usage and mercury-in glass thermometer, it is suitable to determine the oxidation stability of gasoline.

Type Compact; Desktop
Design Integrated
Bath Metal bath (without water usage)
Temperature control point of metal bath 100℃ ± 1℃
Ambient temperature ≤ 30℃
IPC Built-in
Work mode Automatic
Display 10.1 inch color touch LCD display
Operation system Windows
Sample testing Parallel
Oxygen bomb assembly Unit body designed
Measuring range of oxygen bomb pressure transmitter 0 to 1600 KPa
Accuracy ±2 KPa
Curve/graph Real time
Thermometer Mercury-in glass thermometer, can correct coefficient as need
Heating power 1600 W (automatically controlled by IPC)
Relative humidity ≤85%
Dimension (W×D×H) 380×470×320 mm (without test barrel); 380×470×600 mm (with test barrel)
Weight 25 kg (approx)
  • Compact, desktop structured instrument with integrated design
  • Built-in IPC, automation work mode, 10.1 inch color touch LCD display, Windows operation system
  • Double holes design to test two samples at the same time; parallel testing
  • Well-designed heat preservation system for energy saving as well as prevent operator from scalding
  • Unit-body designed bomb assembly, shorts the pressure testing pipe and makes the pressure determination more accurate
  • Bomb being well sealed to make the test result more reliable
  • Oxygen bomb location hole design, convenient for operator to disassemble the cover of oxygen bomb in holes, and easy to put the oxygen bomb during the test
  • Color LCD real-time display the two bomb test curve chart, two bombs comparative curve chart, time and pressure etc. relative data
  • Automatic change in curved time graph as per curve real time length ( maximum: 3000 min)
  • Wide application and direct reading test results
  • High automatic software design for automatic operation; User-friendly interface

Gasoline oxidation stability testers utilized in the petrochemical, bio-chemical materials, food science, and other industries for determination of the oxidation stability of gasoline.

Samples 8
Temperature 100 ℃
Temperature controlling accuracy 0.1 ℃
Flow meter 3 ± 0.3 L / H oxygen
Temperature Range Ambient to 150℃
Temperature Precision ± 0.1°C
Test Unit 2 units
Heating Power 1800 W
Samples 6
Temperature controlling mode Automatic digital temperature
Temperature controlling range Room temperature ~ 160 °C
Temperature controlling accuracy ± 0.2 °C
Samples 2
Oil bath cubage 30 L
Angle between bomb and water surface 30 °
Speed of rotary assembly 100 ± 5 RPM
Ambient temperature 10 °C ~ 40 ℃
Relative humidity ≤ 80 %
Ignition Mode electron igniter / gas flame
Temperature range Room Temperature ~ 300 ℃
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Temperature range 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Aperture of ignition device 0.8 mm
Ambient temperature 10 °C ~ 40 °C
Relative humidity ≤ 80 %
Measurement Range Ambient Temperature ~ 250 °C
Flash Point Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C
Sample quantity 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time 60, 120, 240, 300, and 600 s at random
Measurement range 7 ppm to 5 %
Repeatability < 0.029 (S + 0.6)
Air flow rate Not less than 150 L / h
Max. Preset time 99 min 59 s (100 min)
Chamber diameter of oven Φ22 mm
Heating power of oven 1400 W × 2
Thermometer 6 ℃ ~ 400 ℃
Scale Division 2 °C
Spout Aperture 0.6 ~ 0.8 mm
Ambient Temperature -10 ℃ ~ 50 ℃
Thermometer 0 ℃ ~ 360 °C
Scale Division 1 °C
Ambient Temperature ≤ 35 °C
Relative Humidity ≤ 85 %
Ambient Temperature 10 ℃ ~ 40 ℃
Relative Humidity ≤ 85 %
Temperature Measurement- Full Scale Ambient temperature to ~ 400 ℃
Temperature Measurement- Repeatability ≤ 4 ℃
Measurement range ≥0.05 mg KOH/g
Potential measurement range 0 to 1800.0 mV
Burette volume 10 mL
Minimum titration volume 0.001 ml
Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml
Ambient temperature (-10 )°C to 35 °C
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml
Total power consumption ≤ 1200 W
 Temperature range Room temperature to 1000 ºC
Temperature resolution 0.1 ºC
Temperature fluctuation ±0.1 ºC
Heating rate 1 ~ 80 ºC / min