Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

Labtron LOST-D10 is devised with Software-controlled test procedure which can check pressure, record test data and calculate oxidation time for measured sample automatically. Test curves and test data will be archived in database. It is made as per ASTM D2272 Standard

Samples 2
Temperature
Oil bath cubage 30 L
Angle between bomb and water surface 30 °
Speed of rotary assembly 100 ± 5 RPM
Pressure sensor 0 to 1.6 Mpa; Accuracy: ±2%
Oil bath Temperature controlling range RT to 200 °C (adjustable)
Temperature controlling mode
Temperature controlling range
Temperature controlling accuracy ± 0.1 °C
Flow meter
Size 550 × 800 × 1000 mm
Power of heater 2500 W
Power supply 220 V ± 10 %
Power consumption
Weight 45 kg
Dimension 860 × 710 × 104 mm
  • Fully Automatic
  • High test precision
  • Short heating-up time
  • Software-controlled test procedure
  • Data and test results will be archived in database

It is suitable to determine oxidation stability of new or in service turbine oil, which has the same components (base oil and additive). It is also a rapid method for determining the oxygen stability of new mineral insulating oils containing 2, 6-Di-tert-butyl-p-cresol.

Samples 6
Temperature controlling mode Automatic digital temperature
Temperature controlling range Room temperature ~ 160 °C
Temperature controlling accuracy ± 0.2 °C
Type Compact; Desktop
Design Integrated
Bath Metal bath (without water usage)
Temperature control point of metal bath 100℃ ± 1℃
Samples 8
Temperature 100 ℃
Temperature controlling accuracy 0.1 ℃
Flow meter 3 ± 0.3 L / H oxygen
Temperature Range Ambient to 150℃
Temperature Precision ± 0.1°C
Test Unit 2 units
Heating Power 1800 W
Samples 8
Temperature 100 ℃
Temperature controlling accuracy 0.1 ℃
Flow meter 3 ± 0.3 L / H oxygen
Samples 6
Temperature controlling mode Automatic digital temperature
Temperature controlling range Room temperature ~ 160 °C
Temperature controlling accuracy ± 0.2 °C
Samples 2
Oil bath cubage 30 L
Angle between bomb and water surface 30 °
Speed of rotary assembly 100 ± 5 RPM
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Temperature controlling range Room temperature to 99.9 °C
Temperature controlling accuracy ± 1 °C
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Timing range 1 s to 9 min 59 s
Temperature controlling range Room temperature to 99.9 °C
Graduated Flask 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Ambient Temperature 10 °C ~ 40 °C
Graduated Flask 200 ± 0.2 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.2 °C
Graduated Flask 100 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.1 °C
 Measuring Range For Aviation Gasoline 86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor Vehicles National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For Ethanol E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel Fuels Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI
Measurement item motor gasoline and diesel
measurement unit of octane is ON 40 to 120
Permissible error of octane ± 0.5 max
Fluctuate range of octane ± 0.2 max
Measuring range 0 to 700 taper degree (digital display table 0-70 mm)
Timing device Timing error is less than ±0.1 s
 Resolution 0.01 mm
Needle insertion accuracy ±1 cone insertion degree