Automatic Thermogravimetric Analyzer LTGA-A10

Automatic Thermogravimetric Analyzer LTGA-A10 is a high performance, efficient unit designed to study thermal stability of materials and its allied components. It offers a resolution of 0.1 ºC and works between temperature range of room temperature to 1000 ºC. Operates in an inert, oxidizing, reducible, static and dynamic atmosphere and possess two-way gas and control flow volume.

 Temperature range Room temperature to 1000 ºC
Temperature resolution 0.1 ºC
Temperature fluctuation ±0.1 ºC
Heating rate 1 ~ 80 ºC / min
Cooling time 15min  (1000ºC ~ 100ºC)
 Balance measuring range 1mg~2g  (Can be extended to 30g)
 Resolution 0.1 u g
Constant temperature and time 0 ~ 300min (set arbitrarily)
Atmosphere Inert, oxidizing, reducible, static and dynamic
Power AC220V, 50Hz
  • LCD display
  • Two-way gas and control flow volume
  • Built-in gas flow meter
  • Temperature control mode: Rising temperature, Cooling temperature, Constant temperature
  • Software to record TG curves automatically
  • Data processing and print data results
  • RS232 interface

Thermogravimetric Analyzer gives automatic analysis of Thermal stability, Moisture, Volatiles, Ash, Fixed Carbon Special application for Coal & Coke.

Measurement range 32 ℃ to 160 ℃
Ambient temperature 35 °C
Temperature resolution 0.01 ℃
Beaker volume 1000 mL
Thermometer 6 ℃ ~ 400 ℃
Scale Division 2 °C
Spout Aperture 0.6 ~ 0.8 mm
Ambient Temperature -10 ℃ ~ 50 ℃
Ambient Temperature 10 ℃ ~ 40 ℃
Relative Humidity ≤ 85 %
Temperature Measurement- Full Scale Ambient temperature to ~ 400 ℃
Temperature Measurement- Repeatability ≤ 4 ℃
Thermometer 0 ℃ ~ 360 °C
Scale Division 1 °C
Ambient Temperature ≤ 35 °C
Relative Humidity ≤ 85 %
Temperature Range Ambient to 100°C
Temperature Precision ± 0.1°C
Air Flow 94 mL ± 5 mL/min, with flowmeters
Timing Unit 0 to 99 min 59 s, resolution 1 s
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Timing range 1 s to 9 min 59 s
Temperature controlling range Room temperature to 99.9 °C
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Temperature controlling range Room temperature to 99.9 °C
Temperature controlling accuracy ± 1 °C
Air flow rate Not less than 150 L / h
Max. Preset time 99 min 59 s (100 min)
Chamber diameter of oven Φ22 mm
Heating power of oven 1400 W × 2
Sample quantity 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time 60, 120, 240, 300, and 600 s at random
Measurement range 7 ppm to 5 %
Repeatability < 0.029 (S + 0.6)