Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11 automatically detects the refrigerating capacity and balances the circulation system in co-relation to its last caloric value. Bomb is placed on the lifting device using lifting system. Equipped with latest oxygen bomb, auto oxygen filling system, and auto elevating system ensures, for error-free running of operational process.

Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode
Temperature resolution 0.0001°C
Precision RSD ≤0.1 %
Testing time 8 min
Power ≤1.5 kW
Power supply 220 V, 50/60 Hz
Dimension 630 × 420 × 450 mm
Weight 55 kg
  • Compressor water refrigeration system
  • High efficiency magnetic churning facility
  • Probe type electronic measuring cup to measure inner bucket water
  • No need to measure, fill water and adjust water temperature
  • Auto stop and auto draining joints
  • Use of advance USB technology
  • Supports Windows system, links electronic scale, shares data via network
  • CE certified
Accessories no. Name Unit Qty.
1 Ignition thread (500 pieces) Box Box 20
2 Standard Benzoic Acid (1 gm * 10 pieces) Bottle 10
3 Gasket Ring for Oxygen Filling Facility (big, middle, small) Set 15
4 Heating Crucible PC 60
5 Oxygen bomb gasket ring (big, middle, small) Set 15
6 Plastic insulation cover Set 5
7 Special Oxygen filling pipe PC 2
8 Electrodes Set 1

Used in coal, petroleum, cement, farming, medical research, electronics for measurement of calorific value of solid and liquid combustible materials.

Calorimeter type Isoperibol
Oxygen filling Semi-automatic
Bomb volume 282 ml
Analysis time 15 to 25 min
Calorimeter type Isoperibol
Oxygen filling Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume 250 ml
Analysis time < 8 min full test process: <10 min
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode The outer barrel temperature is constant
Calorimeter type Isoperibol
Oxygen filling Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume 250 ml
Analysis time < 8 min full test process: <10 min
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode The outer barrel temperature is constant
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode
Ambient temperature 10 °C ~ 40 °C
Relative humidity ≤ 80 %
Measurement Range Ambient Temperature ~ 250 °C
Flash Point Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C
Ambient temperature 10 °C ~ 40 ℃
Relative humidity ≤ 80 %
Ignition Mode electron igniter / gas flame
Temperature range Room Temperature ~ 300 ℃
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Temperature range 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Aperture of ignition device 0.8 mm
Sample quantity 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time 60, 120, 240, 300, and 600 s at random
Measurement range 7 ppm to 5 %
Repeatability < 0.029 (S + 0.6)
Air flow rate Not less than 150 L / h
Max. Preset time 99 min 59 s (100 min)
Chamber diameter of oven Φ22 mm
Heating power of oven 1400 W × 2
Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01
Breakdown sensitivity < 0.1 kV
Measurement range 32 ℃ to 160 ℃
Ambient temperature 35 °C
Temperature resolution 0.01 ℃
Beaker volume 1000 mL