Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11 automatically detects the refrigerating capacity and balances the circulation system in co-relation to its last caloric value. Bomb is placed on the lifting device using lifting system. Equipped with latest oxygen bomb, auto oxygen filling system, and auto elevating system ensures, for error-free running of operational process.

Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode
Temperature resolution 0.0001°C
Precision RSD ≤0.1 %
Testing time 8 min
Power ≤1.5 kW
Power supply 220 V, 50/60 Hz
Dimension 630 × 420 × 450 mm
Weight 55 kg
  • Compressor water refrigeration system
  • High efficiency magnetic churning facility
  • Probe type electronic measuring cup to measure inner bucket water
  • No need to measure, fill water and adjust water temperature
  • Auto stop and auto draining joints
  • Use of advance USB technology
  • Supports Windows system, links electronic scale, shares data via network
  • CE certified
Accessories no. Name Unit Qty.
1 Ignition thread (500 pieces) Box Box 20
2 Standard Benzoic Acid (1 gm * 10 pieces) Bottle 10
3 Gasket Ring for Oxygen Filling Facility (big, middle, small) Set 15
4 Heating Crucible PC 60
5 Oxygen bomb gasket ring (big, middle, small) Set 15
6 Plastic insulation cover Set 5
7 Special Oxygen filling pipe PC 2
8 Electrodes Set 1

Used in coal, petroleum, cement, farming, medical research, electronics for measurement of calorific value of solid and liquid combustible materials.

Calorimeter type Isoperibol
Oxygen filling Semi-automatic
Bomb volume 282 ml
Analysis time 15 to 25 min
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode The outer barrel temperature is constant
Calorimeter type Isoperibol
Oxygen filling Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume 250 ml
Analysis time < 8 min full test process: <10 min
Graduated Flask 100 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.1 °C
Graduated Flask 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Ambient Temperature 10 °C ~ 40 °C
Graduated Flask 200 ± 0.2 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.2 °C
Evaporation bath type and size Aluminum bath φ260 × 130 mm
Holes for testing 5 pieces
Size of holes for testing cylinder φ51 × 70 mm
Working temperature 160 ℃ ~ 165℃
Bath type Oil bath
Bath capacity 5000 ml ± 50 ml
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Evaporation bath type and size Aluminum block bath, φ260 × 130 mm
Holes for testing 3 pieces
Size of holes for testing cylinder φ51 × 70 mm
Flow rate display Flow meter
Ambient temperature 10 °C ~ 40 ℃
Relative humidity ≤ 80 %
Ignition Mode electron igniter / gas flame
Temperature range Room Temperature ~ 300 ℃
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Temperature range 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Aperture of ignition device 0.8 mm
Ambient temperature 10 °C ~ 40 °C
Relative humidity ≤ 80 %
Measurement Range Ambient Temperature ~ 250 °C
Flash Point Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C
Experimental temperature range -50 to 70°C
Test sample volume 50 ml
Ambient temperature range 10 to 40°C
Humidity ≤ 85%
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W × 2
Sample Determination 2 at a time
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W
Sample Determination 1 at a time
Ambient Temperature 10°C to 35°C
Measurement Range 0 to 100 mg
Resolution 0.1 µg
Max. Electrolysis Speed 40 µg /s