Dropping Point Tester (Air bath) LDPT-A11

Labtron LDPT-A11 is designed and made as per the “Test Methods for Dropping Point of Lubricating Grease and Solid Hydrocarbon” ASTM D566.

Beaker quantity
Ambient temperature ≤ 35 ℃
Relative humidity ≤ 85 %
Thermometer Measurement range
Thermometer Scale division
Thermometer Immersion depth
Thermometer Total length
Grease cup Material
Grease cup Inner diameter
Grease cup Orifice
Grease cup Height
Test tube Material
Test tube Inner diameter
Heater
Stirring motor
Dimensions
Heating power of electric furnace 250 W × 2
Total power consumption ≤ 700 W
Power supply AC 220 V ± 10 %, 50 Hz
  • Desktop structure
  • Controlled by bidirectional silicon controlled rectifier
  • Double sample working style. It can do parallel test for two samples at a time

It is used to determine dropping point of lubricating grease and hydrocarbon over 100 ℃

Beaker quantity 600 ml
Ambient temperature (-10) °C ~ 40 °C
Relative humidity ≤ 85 %
Thermometer Measurement range (-5) °C ~ 300 °C
Measurement range 32 ℃ to 160 ℃
Ambient temperature 35 °C
Temperature resolution 0.01 ℃
Beaker volume 1000 mL
Refrigeration system New-type refrigeration compressor
Controlling temperature of cold trough Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Ambient temperature (-10)℃ ~ 35 ℃
Relative humidity ≤ 85 %
Sample cup Inner diameter 31.0 ~ 32.0 mm
Sample cup Wall thickness 1.0 ~ 1.5 mm
Temperature controlling accuracy ± 0.5 ℃
Refrigeration system New-type refrigeration compressor
Cold trough Two holes in one trough, and same temperature
Ambient temperature ≤ 30 ℃
Ambient temperature ≤ 35 ℃
Relative humidity ≤ 85 %
Heating power of electric furnace 250 W × 2
Total power consumption ≤ 700 W
Beaker quantity 600 ml
Ambient temperature (-10) °C ~ 40 °C
Relative humidity ≤ 85 %
Thermometer Measurement range (-5) °C ~ 300 °C
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Temperature range 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Aperture of ignition device 0.8 mm
Ambient temperature 10 °C ~ 40 °C
Relative humidity ≤ 80 %
Measurement Range Ambient Temperature ~ 250 °C
Flash Point Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C
Ambient temperature 10 °C ~ 40 ℃
Relative humidity ≤ 80 %
Ignition Mode electron igniter / gas flame
Temperature range Room Temperature ~ 300 ℃
Measurement range 0 to 600 penetration scale
Timing controller 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.01 mm
Penetrometer
Measurement range 0 to 600 penetration scale
Timing controller 5 sec or 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.1 penetration
Penetration accuracy ± 1 penetration
Weight of standard needle 2.5 ± 0.05 g
Dimensions (W × L × H) 700 × 400 × 750 mm
Weight 30 kg
Circulatory Water Bath
Bath volume 3.5 L
Temperature range 5 °C to 60 °C
Temperature accuracy ± 0.1 °C
Circulatory water quantity 3 L/minute
Pump Lift 2 m
Power consumption 1200 W
Power supply AC 220V ± 10 %, 50 Hz
Dimensions (W × L × H) 600 × 400 × 650 mm
Weight 40 kg
Measurement range 0 to 600 penetration scale
Timing controller 5 sec or 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.01 mm