Transformer Oil Oxidation Stability Tester LOST-D11

Labtron LOST-D11 features metal bath for uniform heating, keeping the temperature constant. Equipped with pressure reducer ensuring constant output pressure of the gas cylinder when the pressure in the gas cylinder decreases. Furnished with 6 flow meters to adjust and indicate the flow rate in 6 oxidation tubes.

Samples 6
Temperature
Oil bath cubage
Angle between bomb and water surface
Speed of rotary assembly
Pressure sensor
Oil bath Temperature controlling range
Temperature controlling mode Automatic digital temperature
Temperature controlling range Room temperature ~ 160 °C
Temperature controlling accuracy ± 0.2 °C
Flow meter
Size
Power of heater
Power supply 220 V, 50 Hz
Power consumption ≤ 1100 W
Weight
Dimension
  • Digital temperature controller for automatic mode
  • Desktop type and compact
  • Pressure reducer (ensuring constant output pressure)
  • Digital timer (presetting and recording test time)

It can be widely used in petroleum, chemical industries, research and development laboratories.

Type Compact; Desktop
Design Integrated
Bath Metal bath (without water usage)
Temperature control point of metal bath 100℃ ± 1℃
Samples 8
Temperature 100 ℃
Temperature controlling accuracy 0.1 ℃
Flow meter 3 ± 0.3 L / H oxygen
Temperature Range Ambient to 150℃
Temperature Precision ± 0.1°C
Test Unit 2 units
Heating Power 1800 W
Samples 2
Oil bath cubage 30 L
Angle between bomb and water surface 30 °
Speed of rotary assembly 100 ± 5 RPM
Sample hole 4 pieces
Sample quantity 4 to 12 pieces
Ambient temperature Room temperature to 35 °C
Temperature controlling range Room temperature to 100°C
Sample hole 4 pieces
Speed of stirring motor 1400 rpm
Speed for sample stirring 1000 ± 50 rpm
Ambient temperature Room temperature to 35°C
Sample hole 2 pieces
Speed of stirring motor 1400 rpm
Ambient temperature 10 to 35°C
Temperature controlling range Room Temperature to 100°C
Samples 2
Oil bath cubage 30 L
Angle between bomb and water surface 30 °
Speed of rotary assembly 100 ± 5 RPM
Samples 8
Temperature 100 ℃
Temperature controlling accuracy 0.1 ℃
Flow meter 3 ± 0.3 L / H oxygen
Samples 6
Temperature controlling mode Automatic digital temperature
Temperature controlling range Room temperature ~ 160 °C
Temperature controlling accuracy ± 0.2 °C
Viscosity measurement range 10 ~ 2000000 MPa•s
Ambient temperature 5 °C ~ 35 °C
Ambient humidity Not more than 80 %
Spindles Four spindles of No.1 ~ 4
Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01
Breakdown sensitivity < 0.1 kV
Ambient temperature 10 °C ~ 40 °C
Relative humidity ≤ 80 %
Measurement Range Ambient Temperature ~ 250 °C
Flash Point Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C
Ambient temperature 10 °C ~ 40 ℃
Relative humidity ≤ 80 %
Ignition Mode electron igniter / gas flame
Temperature range Room Temperature ~ 300 ℃
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Temperature range 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Aperture of ignition device 0.8 mm