Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10 comes with automatic oxygen filling and releasing, fully automatic bomb raising and lowering system. Equipped with propeller to achieve high stirring efficiency, and faster oxygen bomb heat transfer to reduce test period. It is in accordance with international standards ASTM D5865, ISO 1928.

Calorimeter type Isoperibol
Oxygen filling Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume 250 ml
Analysis time < 8 min full test process: <10 min
Bomb washing Manual
Bomb pressure (maximum) 20 MPa
Bomb identity Yes
No. of Tests 6/hour
Temperature resolution 0.0001 K
Precision (RSD) ≤ 0.01 %
Heat Capacity Stability ≤ 0.25 % within three months
Gas requirement 99.5 % oxygen
Water requirements Distilled water
Energy measurement range 0 to 50000 J
Bucket filling Automatic
Stirring method Propeller
Reproducibility 0.10 % (analysis of 1 g of benzoic acid)
Temperature Increase 2°C (average)
Temperature measurement PT1000 (temperature probe)
Working temperatures ≤ 32°C
Cooling type Refrigerating device
Network Yes
Maximum Power 0.6 kW
Power Inverter No
Power supply 220 V ±, 15 to 10 %, 50/60 Hz
Advance Calculations Yes
Dimension Main body: 440 × 550 × 460 mm Water Tank: 390 × 550 × 440 mm
Weight 50 kg
  • Unique bucket water circle system, automatic determination water volume
  • Easy assembly and disassembly of stainless steel oxygen bomb
  • Built-in intelligent water tank with heating and cooling function
  • Helix tube multipoint isothermal technology
  • Independent jacket and bucket water system
  • Large heat capacity with stable and accurate results
  • Self-protection, self-diagnostic function
  • Analysis, statistics report, system monitor
  • Unique crucible support design, easy to use
Accessories no. Name Unit Qty.
1 Ignition thread (500 pieces) Box Box 20
2 Standard Benzoic Acid (1 gm * 10 pieces) Bottle 10
3 Gasket Ring for Oxygen Filling Facility (big, middle, small) Set 15
4 Heating Crucible PC 60
5 Oxygen bomb gasket ring (big, middle, small) Set 15
6 Plastic insulation cover Set 5
7 Special Oxygen filling pipe PC 2
8 Electrodes Set 1

Used in determination of calorific value of solid and liquid combustibles such as coal, coke, oil, petroleum material, biomass, cement and others.

Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode The outer barrel temperature is constant
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode
Calorimeter type Isoperibol
Oxygen filling Semi-automatic
Bomb volume 282 ml
Analysis time 15 to 25 min
Sample hole 2 pieces
Speed of stirring motor 1400 rpm
Ambient temperature 10 to 35°C
Temperature controlling range Room Temperature to 100°C
Sample hole 4 pieces
Speed of stirring motor 1400 rpm
Speed for sample stirring 1000 ± 50 rpm
Ambient temperature Room temperature to 35°C
Sample hole 4 pieces
Sample quantity 4 to 12 pieces
Ambient temperature Room temperature to 35 °C
Temperature controlling range Room temperature to 100°C
Measuring range 0 to 700 taper degree (digital display table 0-70 mm)
Timing device Timing error is less than ±0.1 s
 Resolution 0.01 mm
Needle insertion accuracy ±1 cone insertion degree
Potential measuring range (0 to ±1999.5) Mv
Intrinsic error 0.1 % ±0.5 mV
Input impedance Ri ≥1 × 1012 Ω
Burette capacity 10 mL
Ambient Temperature 10 ℃ ~ 40 ℃
Relative Humidity ≤ 85 %
Temperature Measurement- Full Scale Ambient temperature to ~ 400 ℃
Temperature Measurement- Repeatability ≤ 4 ℃
Thermometer 6 ℃ ~ 400 ℃
Scale Division 2 °C
Spout Aperture 0.6 ~ 0.8 mm
Ambient Temperature -10 ℃ ~ 50 ℃
Thermometer 0 ℃ ~ 360 °C
Scale Division 1 °C
Ambient Temperature ≤ 35 °C
Relative Humidity ≤ 85 %
Ambient temperature 10 °C ~ 40 ℃
Relative humidity ≤ 80 %
Ignition Mode electron igniter / gas flame
Temperature range Room Temperature ~ 300 ℃
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Temperature range 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Aperture of ignition device 0.8 mm
Ambient temperature 10 °C ~ 40 °C
Relative humidity ≤ 80 %
Measurement Range Ambient Temperature ~ 250 °C
Flash Point Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C