Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

Labtron LLTT-A12 is designed with cold filter plugging point test along with proper cooling bath. Equipped as per “Test Methods for Cold Filter Plugging Point of Distillate Fuels”.

Measurement range
Temperature controlling accuracy
Refrigeration system
Bath stirrer
Sample stirrer
Cold trough
Controlling temperature of cold trough
Constant temperature bath Cubage
Constant temperature bath Types
Temperature Range
Temperature sensor
Stirring motor Power
Stirring motor Speed
Ambient temperature (-10)℃ ~ 35 ℃
Relative humidity ≤ 85 %
Refrigeration speed
Repeatability for solidifying point
Repeatability for pour point
Reproducibility
Pressure of cooling water
The lowest temperature
Sample cup Inner diameter 31.0 ~ 32.0 mm
Sample cup Wall thickness 1.0 ~ 1.5 mm
Sample cup Height 115 ~ 125 mm
Pumping pressure U type differential pressure meter 1961 Pa (200 mm H<sub>2</sub>O)
Dimensions
Inner Dimensions
Outer Dimensions
Total power consumption ≤ 150 W
Heating power
Power supply AC 220 V ± 10 %, 50 Hz
  • Relative low temperature tester
  • Round glass cup with flat bottom sample cup
  • Equipped with SH/T0248 “Test Methods for Cold Filter Plugging Point of Distillate Fuels
  • Advance Digital display
  • Integrated structure

It can be widely used in petroleum, chemical industries and environmental studies.

Refrigeration system New-type refrigeration compressor
Controlling temperature of cold trough Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Temperature controlling accuracy ± 0.5 ℃
Refrigeration system New-type refrigeration compressor
Cold trough Two holes in one trough, and same temperature
Ambient temperature ≤ 30 ℃
Temperature controlling accuracy ± 0.5 °C
Refrigeration system New-type refrigeration compressor
Cold trough One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough Room temperature ~ (-70) °C
Temperature controlling accuracy ± 0.5 °C
Refrigeration system New-type refrigeration compressor
Cold trough One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough Room temperature ~ (-70) °C
Refrigeration system New-type refrigeration compressor
Controlling temperature of cold trough Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Freezing point range -54°C to 2°C
Cold bath measurement temperature range -70° to 20°C
Temperature controlling accuracy ±0.5°C
Bath liquids stirring Electric
Ambient temperature ≤ 30 ℃
Refrigeration speed > 40 °C / 10 min
Repeatability for solidifying point ≤ 2 °C
Repeatability for pour point ≤ 3 °C
Refrigeration system New-type refrigeration compressor
Cold trough One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough Room temperature ~ (-70) °C
Ambient temperature ≤ 30 ℃
Capacity 20 L
Temperature range Ambient +5°C to 100°C
Precision ± 0.1℃
Stirring range 1200 r/min
Chamber quantity 2 chambers
Chamber 01 temperature control Ambient to -51 ℃
Chamber 02 temperature control Ambient to -65 ℃
Temperature precision ±1°C
Evaporation bath type and size Aluminum bath φ260 × 130 mm
Holes for testing 5 pieces
Size of holes for testing cylinder φ51 × 70 mm
Working temperature 160 ℃ ~ 165℃
Bath type Oil bath
Bath capacity 5000 ml ± 50 ml
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Evaporation bath type and size Aluminum block bath, φ260 × 130 mm
Holes for testing 3 pieces
Size of holes for testing cylinder φ51 × 70 mm
Flow rate display Flow meter
Measurement item motor gasoline and diesel
measurement unit of octane is ON 40 to 120
Permissible error of octane ± 0.5 max
Fluctuate range of octane ± 0.2 max
 Measuring Range For Aviation Gasoline 86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor Vehicles National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For Ethanol E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel Fuels Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI
 Temperature range Room temperature to 1000 ºC
Temperature resolution 0.1 ºC
Temperature fluctuation ±0.1 ºC
Heating rate 1 ~ 80 ºC / min
Samples 6
Temperature controlling mode Automatic digital temperature
Temperature controlling range Room temperature ~ 160 °C
Temperature controlling accuracy ± 0.2 °C
Samples 2
Oil bath cubage 30 L
Angle between bomb and water surface 30 °
Speed of rotary assembly 100 ± 5 RPM
Samples 8
Temperature 100 ℃
Temperature controlling accuracy 0.1 ℃
Flow meter 3 ± 0.3 L / H oxygen
Experimental temperature range -50 to 70°C
Test sample volume 50 ml
Ambient temperature range 10 to 40°C
Humidity ≤ 85%