Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

Labtron LLTT- A15 is manufactured with two cold trough with same temperature. The instrument is designed and made as per ASTM D2386 “Test Methods for Solidifying Point of Petroleum Products”, and ASTM D6371 “Test Methods for Cold Filter Plugging Point of Distillate Fuel

Measurement range
Temperature controlling accuracy
Refrigeration system New-type refrigeration compressor
Bath stirrer
Sample stirrer
Cold trough
Controlling temperature of cold trough Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Constant temperature bath Cubage
Constant temperature bath Types
Temperature Range
Temperature sensor
Stirring motor Power
Stirring motor Speed
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Refrigeration speed
Repeatability for solidifying point
Repeatability for pour point
Reproducibility
Pressure of cooling water
The lowest temperature
Sample cup Inner diameter
Sample cup Wall thickness
Sample cup Height
Pumping pressure
Dimensions
Inner Dimensions 560 x 380 x 250 mm
Outer Dimensions 920 x 670 x 510 mm
Total power consumption ≤ 1500 W
Heating power
Power supply AC 220 V ± 10 %, 50 Hz
  • Cold filter plugging point is provided
  • No need to use cooling liquid in the chambers
  • Composed of two chambers having same temperature
  • Both solidifying point test and cold filter plugging point test provided

It can be widely used in petroleum (solidifying point and cold filter plugging point), chemical industries, research and development laboratories.

Temperature controlling accuracy ± 0.5 °C
Refrigeration system New-type refrigeration compressor
Cold trough One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough Room temperature ~ (-70) °C
Capacity 20 L
Temperature range Ambient +5°C to 100°C
Precision ± 0.1℃
Stirring range 1200 r/min
Refrigeration system New-type refrigeration compressor
Cold trough One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough Room temperature ~ (-70) °C
Ambient temperature ≤ 30 ℃
Temperature controlling accuracy ± 0.5 °C
Refrigeration system New-type refrigeration compressor
Cold trough One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough Room temperature ~ (-70) °C
Freezing point range -54°C to 2°C
Cold bath measurement temperature range -70° to 20°C
Temperature controlling accuracy ±0.5°C
Bath liquids stirring Electric
Ambient temperature ≤ 30 ℃
Refrigeration speed > 40 °C / 10 min
Repeatability for solidifying point ≤ 2 °C
Repeatability for pour point ≤ 3 °C
Ambient temperature (-10)℃ ~ 35 ℃
Relative humidity ≤ 85 %
Sample cup Inner diameter 31.0 ~ 32.0 mm
Sample cup Wall thickness 1.0 ~ 1.5 mm
Chamber quantity 2 chambers
Chamber 01 temperature control Ambient to -51 ℃
Chamber 02 temperature control Ambient to -65 ℃
Temperature precision ±1°C
Refrigeration system New-type refrigeration compressor
Controlling temperature of cold trough Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Temperature controlling accuracy ± 0.5 ℃
Refrigeration system New-type refrigeration compressor
Cold trough Two holes in one trough, and same temperature
Ambient temperature ≤ 30 ℃
Evaporation bath type and size Aluminum block bath, φ260 × 130 mm
Holes for testing 3 pieces
Size of holes for testing cylinder φ51 × 70 mm
Flow rate display Flow meter
Evaporation bath type and size Aluminum bath φ260 × 130 mm
Holes for testing 5 pieces
Size of holes for testing cylinder φ51 × 70 mm
Working temperature 160 ℃ ~ 165℃
Bath type Oil bath
Bath capacity 5000 ml ± 50 ml
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Temperature controlling accuracy ± 0.5 ℃
Refrigeration system New-type refrigeration compressor
Cold trough Two holes in one trough, and same temperature
Ambient temperature ≤ 30 ℃
Ambient temperature (-10)℃ ~ 35 ℃
Relative humidity ≤ 85 %
Sample cup Inner diameter 31.0 ~ 32.0 mm
Sample cup Wall thickness 1.0 ~ 1.5 mm
Refrigeration system New-type refrigeration compressor
Controlling temperature of cold trough Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml
Total power consumption ≤ 1200 W
Measurement range ≥0.05 mg KOH/g
Potential measurement range 0 to 1800.0 mV
Burette volume 10 mL
Minimum titration volume 0.001 ml
Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml
Ambient temperature (-10 )°C to 35 °C
Measurement range 32 ℃ to 160 ℃
Ambient temperature 35 °C
Temperature resolution 0.01 ℃
Beaker volume 1000 mL
 Measuring Range For Aviation Gasoline 86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor Vehicles National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For Ethanol E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel Fuels Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI
Measurement item motor gasoline and diesel
measurement unit of octane is ON 40 to 120
Permissible error of octane ± 0.5 max
Fluctuate range of octane ± 0.2 max