Rockwell hardness meter TRHM-A10

Rockwell hardness meter TRHM-A10 is used for the testing of ferrous & non-ferrous materials at Rockwell scale. The high quality stainless steel used in its preparation assures reliability & durability of the hardness tester. With novel appearance its analogue gauge display the hardness indication with good resolution. Equipped with oil pump controls test operations, it reduces operator’s involvement.

Preliminary test force 98 N
Total test force 588, 980, 1471 N
Brinell hardness test
Vickers hardness test
Magnification of Microscope
Total test force dwell time 0 to 30 S
Hardness indication Analogue display
Resolution 0.5 HR
Loading control Manual
Maximum height of specimens 170 mm
Distance from Indenter’s center to outer wall 165 mm
Range of Rockwell hardness value HRA 20 to 88<br/> HRB 20 to 100<br/> HRC 20 to 70
Dimension of the machine 510 × 230 × 750 mm
Weight 85 kg
Power supply AC 220 V , 50 Hz
  • Analogue display with resolution of 0.5 HR
  • Manual loading control
  • Rockwell scale HRA, HRB, HRC
  • Cone diameter indenter
  • Stainless steel weight selection control knob
  • Outside body with cast –iron material
  • Can be connected to printer
  • Easy to operate

Rockwell hardness tester has applications in workshops, inspection and production departments, Iron industry for testing.

Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 1 to 30 S
Hardness indication Digital display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Brinell hardness test 306, 613, 1839 N
Vickers hardness test 294, 588, 980 N
Frequency (continually adjustable) 10 Hz to1280 Hz + 0.01 %
Amplitude acceleration ( at 30m/s2 pk ) 40 Hz to 320 Hz + 0.3 dB + 1 digit
Amplitude velocity ( at 25mm / sec pk ) 40 Hz to 320 Hz + 0.5dB +1 digit
Amplitude displacement ( at 50 μm pk-pk ) 40 Hz to 320 Hz + 0.5 dB + 1 digit
Test force 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
Hardness value symbol HV1, HV5, HV10, HV20, HV30, HV250
Error range in display ± 3.0 %, ± 2.0 %
Hardness indication Digital display
Test force 612.5 N, 980 N, 1225 N
Brinell hardness test 1837.5 N, 2450 N, 4900 N/7350 N, 9800 N, 14700 N/29400 N
Hardness measuring area 8 to 650 HBW (hard metals steel ball)
Hardness indication Digital display
Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min </br> -30℃ to -40℃ around 2.5 ℃/min </br> -40℃ to -70℃ around 2.0 ℃/min</br>
Max dimension L × W × H 910 × 510 × 860 mm
Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control
Display LED display
Test arm weight 2.5 N
Additional Loads 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler 150 mm
Abrasion stroke 40 ± 0.2 M
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Salinity Measurement range 0.00 to 19.99 ms/cm
Measuring accuracy EC ± 2% full scale
Temperature Measurement range -5 to 50°C
Temperature accuracy ± 0.5°C
Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU
Repeatability 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source
Zero drift ≤ 0.1 %
Sample (size) length 38×70 mm
Measuring range (1-500) mN.m (divided into 7 small ranges)
Indication error 0.02
Test speed (200° ± 20°)/ min
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min
Accuracy Chromaticity co-ordinate 0.0001
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 0 to 30 S
Hardness indication Analogue display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Brinell hardness test 306, 613, 1839 N
Vickers hardness test 294, 588, 980 N
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 1 to 30 S
Hardness indication Digital display