Soil Salinity tester TSST-A10

Soil Salinity tester TSST-A10 with handheld design is suitable for accurate measurement of both soil temperature & soil salinity. Equipped with easy to use key buttons, user friendly controls, durable design, it is perfect for the field operations across agriculture, gardening, and construction industry.

Salinity Measurement range 0.00 to 19.99 ms/cm
Measuring accuracy EC ± 2% full scale
Temperature Measurement range -5 to 50°C
Temperature accuracy ± 0.5°C
Temperature compensation 0 to 50°C
Resolution 0.01 ms/cm
Memory storage Stores 12000 groups data storage
Working temperature 0 to 50 °C
Gross weight 15 kg
Power 5 pcs AA batteries, power adapter
  • Automatic temperature compensation mode
  • LCD touch display
  • Large storage capacity
  • Easy insertions in to the soil
  • Automatic data recording
  • Continuous measurement design

Used to measure soil salinity of fertile, regular, dry soil etc. in agriculture, farming industry and across scientific research labs, geology.

Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Measurement range 0 to 90 %
Resolution 0.1 or 0.01
Accuracy ± 5 % n (non-saturation condition)
Needle 235 mm
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Maximum load 100 kg ( kg and N can be switched automatically)
Resolution 0.01 g
Accuracy ± 0.5 %
Measuring depth 0 to 40 mm
Measuring range 0 to 100 kPa
Resolution 0.01 kPa
Accuracy ± 1 kPa
Soil temperature measuring range -55 to 105°C
Maximum load 100 kg ( kg and N can be switched automatically)
Resolution 0.01 g
Accuracy ± 0.5 %
Measuring depth 0 to 450 mm
Measurement range 0 to 80 %
Resolution 0.1
Accuracy ± 2 % n (non-saturation condition)
Needle 280 mm
Measurement range 0 to 60 %
Resolution 0.1
Accuracy ± 5 % n (non-saturation condition)
Needle 280 mm
Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU
Repeatability 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min
Accuracy Chromaticity co-ordinate 0.0001
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source
Zero drift ≤ 0.1 %
Sample (size) length 38×70 mm
Measuring range (1-500) mN.m (divided into 7 small ranges)
Indication error 0.02
Test speed (200° ± 20°)/ min
Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control
Display LED display
Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min </br> -30℃ to -40℃ around 2.5 ℃/min </br> -40℃ to -70℃ around 2.0 ℃/min</br>
Max dimension L × W × H 910 × 510 × 860 mm
Test arm weight 2.5 N
Additional Loads 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler 150 mm
Abrasion stroke 40 ± 0.2 M
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Brinell hardness test 306, 613, 1839 N
Vickers hardness test 294, 588, 980 N
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 0 to 30 S
Hardness indication Analogue display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 1 to 30 S
Hardness indication Digital display
Salinity Measurement range 0.00 to 19.99 ms/cm
Measuring accuracy EC ± 2% full scale
Temperature Measurement range -5 to 50°C
Temperature accuracy ± 0.5°C
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005