Carton compression tester TP-I10

Carton compression tester TP-I10 with 100 mm/min return speed level measures the compressive strength of carton box. The compressor tester, adopted with ARM chip, powerful data functioning system, advanced sensor and automatic tracking system for test operations. The test results are recorded automatically, the real-time display is used to view the test data and is transferrable to computer.

Measuring range 0.1 to 10 kN
Capacity
Resolution
Indication error < ± 1%
Tearing arm
Tearing angle
Chips distance
Clamp- paper
Resection length
Tearing distance
Frictional resistance
Pyramid dimension
Platen Size 500×500 mm (customized)
Operating stroke 500 mm (customized)
Compression speed 10 mm/ min
Impact angle
Unit
Error
Sample amount
Speed adjustment range 2 to 100 mm/ min
Track & force speed in stacking test 2 mm/ min
Test area
Area differential pressure
Inner diameter of grip ring
Dimension
Weight
Power supply AC220 V ± 10 % , 50 Hz
  • Touch screen display
  • Customized design as per user’s need
  • Use of high precision pressure sensor for accurate measurement
  • Tests the maximal strength of box using ‘Strength test’
  • Data presetting to test the strength & variant of the carton box ‘Definite value test’
  • Stacking test is performed within 12 or 24 hours
  • Adopted with whorl and guide pillar for stability

Carton compression tester is used to determine compression strength & estimate stacking test of transport packages such as corrugated carton, paperboard box etc.

Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min
Accuracy Chromaticity co-ordinate 0.0001
Measuring range 0 to 20 mm
Accuracy 0.01 mm
Gauge Analogue gauge display
Contact pressure (to create false weight) 20 ± 0.5 kPa
Testing speed 200° ± 20° / min
Test range 1 to 10000 mN
Indicating Error ± 1 %
Testing length 5, 10, 15, 20, 25, 50 mm
Sample (size) length 38×70 mm
Measuring range (1-500) mN.m (divided into 7 small ranges)
Indication error 0.02
Test speed (200° ± 20°)/ min
Measuring range 1 to 50 kN
Indication error < ± 1%
Platen Size 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)
Operating stroke 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)
Measuring range 0 to 1000 ml/min
Test area 10 ± 0.02 cm2
Area differential pressure 1 ± 0.01 kPa
Inner diameter of grip ring 35.68 ± 0.05 mm
Sample diameter 125 mm
Sample error ± 0.2 mm
Sample Thickness 0.1 to 1.0 mm
Dimension 240×288×435 mm
Sample (size) length 90 to 200 mm
Sample width 15 mm, 25 mm, 50mm
Measuring range 0 to 30, 0 to 100 N,0 to 300 N
Accuracy ± 1 %
Measurement range 0 to 100° SR
Sealed testing speed 100 ± 10 mm/s
Volume of distilled water 1000 ± 5 ml
Draining time 149 ± 1 s
Measuring scope ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
Accuracy ±0.1 s within 300 s
Vacuum system volume (ml) Bigger volume: 380 ± 1<br/> Smaller volume: 38 ± 1
Contact pressure 100 ± 2 kPa
Capacity A: 20 to 500 J/m2 B: 500 to 1000 J/m2
Impact angle 90°
Unit Lb-ft/in2  J/m2
Error A: ± 1 J/m2 B: ± 2 J/m2
Sample width 15 mm
Sample maximum length 300 mm
Parallelism ≤ 0.1 mm
Dimension 240×520×70 mm
Measuring range A (1 to 6) J indicating error ± 0.05 J<br/> B (1 to 12) J indicating error ± 0.05 J<br/> C (1 to 24) J indicating error ± 0.05 J<br/> D (1 to 48) J indicating error ± 0.05 J<br/> The indicating errors w.r.t measurement range of 20 to 80 %
Frictional resistance <0.25 J
Pyramid dimension Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm
Dimension 800×470×840 mm
Measurement range 0 to 5600 kPa
Accuracy ± 0.5 % F.S.
Compression speed 170 ± 15 ml/min
Clamp pressure ≥ 690 kPa
Sample (size) length 0 to 200 mm adjustable
Sample width 15 mm
Measuring range 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy ± 1 %
Test arm weight 2.5 N
Additional Loads 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler 150 mm
Abrasion stroke 40 ± 0.2 M
Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min </br> -30℃ to -40℃ around 2.5 ℃/min </br> -40℃ to -70℃ around 2.0 ℃/min</br>
Max dimension L × W × H 910 × 510 × 860 mm
Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control
Display LED display
Sample (size) length 38×70 mm
Measuring range (1-500) mN.m (divided into 7 small ranges)
Indication error 0.02
Test speed (200° ± 20°)/ min
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source
Zero drift ≤ 0.1 %
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min
Accuracy Chromaticity co-ordinate 0.0001
Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU
Repeatability 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Brinell hardness test 306, 613, 1839 N
Vickers hardness test 294, 588, 980 N
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 1 to 30 S
Hardness indication Digital display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 0 to 30 S
Hardness indication Analogue display
The maximum temperature 300°C
Temperature fluctuation Within ± 0.5°C
Temperature uniformity Within ± 1°C
Rotate speed of the turntable 11 r/min to 12r/min, turntable dimension diameter: 285 mm
Resolution 0.1 % O2
Measuring range 0 to 100 % O2
Precision ± 0.4 % O2
Response time < 10 S
Vacuum degree 0 to 90 KPa
Accuracy 1 % FS
Resolution 0.1 KPa
Vacuum chamber effective size 270 × 210 mm