Ink rubber tester TP-F10

Ink rubber tester TP-F10 with benchtop design is used to measure printing ink layers decolorization, rub resistance on low or high printable surface. This tester effectively analyzes the problems of ink decolorization, poor abrasion resistance, photosensitive coating. It helps in identifying the quality of ink and printing method to be used in industry.

Sample size (L*B) 230×50 mm (can join short samples together)
Rub pressure 20 ± 0.2 N
Friction speed 43 times / min
Friction area (L*B) 155×50 mm
No. of friction 0 to 999, auto shutdown
Measuring range
Division value
Accuracy
Gauge
Contact pressure (to create false weight)
Contact diameter
Error of depth parallelism
Testing speed
Test range
Indicating Error
Indication variability
Pressing depth of the measuring head
Parallelism error between two brims of the specimen stages
Slit width of the specimen stage
Testing length
Sample size
Bend angle
Sample width
Sample maximum length
Parallelism
Dimension 275×302×297 mm
Weight 25 kg
Power supply AC220 V ± 10 % , 50 Hz
  • Determines rub resistance bonding of ink
  • Advanced microprocessor controlled system
  • Quiet rubbing process
  • Rub pressure 20 ± 0.2 N
  • Compact & sleek design
  • User friendly operations

Ink rubber tester is used to test rub resistance bonding of ink on printing materials like labels, papers, designs of folding cartons, corrugated boxes etc.

Testing speed 200° ± 20° / min
Test range 1 to 10000 mN
Indicating Error ± 1 %
Testing length 5, 10, 15, 20, 25, 50 mm
Measuring scope ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
Accuracy ±0.1 s within 300 s
Vacuum system volume (ml) Bigger volume: 380 ± 1<br/> Smaller volume: 38 ± 1
Contact pressure 100 ± 2 kPa
Measuring scope 0 to 99999 s
Folding angle 135° ± 2°
Tensile scope 4.9 to 14.7 N
Folding head suture size 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min
Accuracy Chromaticity co-ordinate 0.0001
Sample (size) length 0 to 200 mm adjustable
Sample width 15 mm
Measuring range 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy ± 1 %
Metal Cylinder inner area (100 ± 0.2) cm2
Metal Cylinder height 50 mm
Metal roller width (200 ± 0..5) mm
Metal roller weight (10 ± 0.5) kg
Measuring range 10 to 1000 mN
Division value 1 mN
Accuracy ± 1%
Indicating Error ≤ 0.5
Measuring range 0.1 to 10 kN
Indication error < ± 1%
Platen Size 500×500 mm (customized)
Operating stroke 500 mm (customized)
Sample width 15 mm
Sample maximum length 300 mm
Parallelism ≤ 0.1 mm
Dimension 240×520×70 mm
Measurement range 0 to 1600 kPa
Accuracy ± 0.5 % F.S.
Compression speed 95 ± 5 ml/min
Clamp pressure ≥ 430 kPa
Measuring range 0 to 1000 mN
Resolution 0.1 mN
Indication error ± 1 %
Tearing arm 104 ± 1 mm
Sample (size) length 90 to 200 mm
Sample width 15 mm, 25 mm, 50mm
Measuring range 0 to 30, 0 to 100 N,0 to 300 N
Accuracy ± 1 %
Capacity 10 -16000 mN
Resolution 0.1 mN
Tearing arm 104 ± 1 mm
Tearing angle 27.5° ± 5°
Measurement range 0 to 200 mm
Specimen size 15×250 mm
Division value 1 mm
Number of specimen holders 5
Sample (size) length 180 mm (180, 150, 100, 90, 50 mm adjustable)
Sample width 15 mm
Measuring range 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy ± 1 %
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 0 to 30 S
Hardness indication Analogue display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 1 to 30 S
Hardness indication Digital display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Brinell hardness test 306, 613, 1839 N
Vickers hardness test 294, 588, 980 N
The maximum temperature 300°C
Temperature fluctuation Within ± 0.5°C
Temperature uniformity Within ± 1°C
Rotate speed of the turntable 11 r/min to 12r/min, turntable dimension diameter: 285 mm
Resolution 0.1 % O2
Measuring range 0 to 100 % O2
Precision ± 0.4 % O2
Response time < 10 S
Vacuum degree 0 to 90 KPa
Accuracy 1 % FS
Resolution 0.1 KPa
Vacuum chamber effective size 270 × 210 mm
Sample (size) length 38×70 mm
Measuring range (1-500) mN.m (divided into 7 small ranges)
Indication error 0.02
Test speed (200° ± 20°)/ min
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source
Zero drift ≤ 0.1 %
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min
Accuracy Chromaticity co-ordinate 0.0001
Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU
Repeatability 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Salinity Measurement range 0.00 to 19.99 ms/cm
Measuring accuracy EC ± 2% full scale
Temperature Measurement range -5 to 50°C
Temperature accuracy ± 0.5°C