Paper tearing tester TP-J20

Paper tearing tester TP-J20 is an advanced instrument used for testing tearing strength of the paper and paperboard. This tearing tester comes with 43 ± 0.5 mm tearing distance and 104 mm long tearing arm to locate paper material properly & perform the tearing test.

Measuring range 0 to 1000 mN
Capacity
Resolution 0.1 mN
Indication error ± 1 %
Tearing arm 104 ± 1 mm
Tearing angle 27.5° ± 0.5°
Chips distance
Clamp- paper
Resection length
Tearing distance 43 ± 0.5 mm
Frictional resistance
Pyramid dimension
Platen Size
Operating stroke
Compression speed
Impact angle
Unit
Error
Sample amount
Speed adjustment range
Track & force speed in stacking test
Test area
Area differential pressure
Inner diameter of grip ring
Dimension
Weight
Power supply
  • Compact, portable design
  • Stainless steel right-angled triangular pyramid attached to solid arm design
  • Tearing angle 27.5° with ± 0.5° precision
  • User friendly operations

Paper tearing tester has applications in determining tearing resistance property of paper films, sheets, woven materials, polypropylene, polyester, paper, cardboard, textile material sheets etc.

Measuring range 0 to 20 mm
Accuracy 0.01 mm
Gauge Analogue gauge display
Contact pressure (to create false weight) 20 ± 0.5 kPa
Measuring range 0 to 1000 ml/min
Test area 10 ± 0.02 cm2
Area differential pressure 1 ± 0.01 kPa
Inner diameter of grip ring 35.68 ± 0.05 mm
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source
Zero drift ≤ 0.1 %
Measuring range 0.1 to 10 kN
Indication error < ± 1%
Platen Size 500×500 mm (customized)
Operating stroke 500 mm (customized)
Metal Cylinder inner area (100 ± 0.2) cm2
Metal Cylinder height 50 mm
Metal roller width (200 ± 0..5) mm
Metal roller weight (10 ± 0.5) kg
Sample size (L*B) 230×50 mm (can join short samples together)
Rub pressure 20 ± 0.2 N
Friction speed 43 times / min
Friction area (L*B) 155×50 mm
Measurement range 0 to 200 mm
Specimen size 15×250 mm
Division value 1 mm
Number of specimen holders 5
Sample (size) length 38×70 mm
Measuring range (1-500) mN.m (divided into 7 small ranges)
Indication error 0.02
Test speed (200° ± 20°)/ min
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min
Accuracy Chromaticity co-ordinate 0.0001
Measurement range 0.01 to 10 N
Slider weight 200 g
Slider size 63×63 mm
Testing accuracy ± 2 %
Sample (size) length 90 to 200 mm
Sample width 15 mm, 25 mm, 50mm
Measuring range 0 to 30, 0 to 100 N,0 to 300 N
Accuracy ± 1 %
Measuring range 10 to 1000 mN
Division value 1 mN
Accuracy ± 1%
Indicating Error ≤ 0.5
Measurement range 0 to 5600 kPa
Accuracy ± 0.5 % F.S.
Compression speed 170 ± 15 ml/min
Clamp pressure ≥ 690 kPa
Capacity A: 20 to 500 J/m2 B: 500 to 1000 J/m2
Impact angle 90°
Unit Lb-ft/in2  J/m2
Error A: ± 1 J/m2 B: ± 2 J/m2
Testing speed 200° ± 20° / min
Test range 1 to 10000 mN
Indicating Error ± 1 %
Testing length 5, 10, 15, 20, 25, 50 mm
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min
Accuracy Chromaticity co-ordinate 0.0001
Sample (size) length 38×70 mm
Measuring range (1-500) mN.m (divided into 7 small ranges)
Indication error 0.02
Test speed (200° ± 20°)/ min
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source
Zero drift ≤ 0.1 %
Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU
Repeatability 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)
Resolution 0.1 % O2
Measuring range 0 to 100 % O2
Precision ± 0.4 % O2
Response time < 10 S
Vacuum degree 0 to 90 KPa
Accuracy 1 % FS
Resolution 0.1 KPa
Vacuum chamber effective size 270 × 210 mm
The maximum temperature 300°C
Temperature fluctuation Within ± 0.5°C
Temperature uniformity Within ± 1°C
Rotate speed of the turntable 11 r/min to 12r/min, turntable dimension diameter: 285 mm
Test arm weight 2.5 N
Additional Loads 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler 150 mm
Abrasion stroke 40 ± 0.2 M
Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min </br> -30℃ to -40℃ around 2.5 ℃/min </br> -40℃ to -70℃ around 2.0 ℃/min</br>
Max dimension L × W × H 910 × 510 × 860 mm
Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control
Display LED display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 0 to 30 S
Hardness indication Analogue display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Brinell hardness test 306, 613, 1839 N
Vickers hardness test 294, 588, 980 N
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 1 to 30 S
Hardness indication Digital display