Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 1 to 30 S |
Hardness indication | Digital display |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Brinell hardness test | 306, 613, 1839 N |
Vickers hardness test | 294, 588, 980 N |
Preliminary test force | 98 N |
Total test force | 588, 980, 1471 N |
Total test force dwell time | 0 to 30 S |
Hardness indication | Analogue display |
Test arm weight | 2.5 N |
Additional Loads | 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N, |
Idler | 150 mm |
Abrasion stroke | 40 ± 0.2 M |
Mixed capacity | 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg |
Temperature range | RT to 300°C |
Temperature control system | PID control |
Display | LED display |
Temperature control range | Room temperature to -70 ℃ (room temperature ≤ 25 ℃) |
Temperature accuracy | ± 0.3 ℃ |
Impact speed | 0℃ to -30℃ around 2.5 ℃/min </br> -30℃ to -40℃ around 2.5 ℃/min </br> -40℃ to -70℃ around 2.0 ℃/min</br> |
Max dimension L × W × H | 910 × 510 × 860 mm |
Salinity Measurement range | 0.00 to 19.99 ms/cm |
Measuring accuracy | EC ± 2% full scale |
Temperature Measurement range | -5 to 50°C |
Temperature accuracy | ± 0.5°C |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Repeatability error | A (absorbency of light) <0.005 |
Measuring range | 0.001 to 9999 |
Stability | A (absorbency of light) <0.003 within 3 mins |
Linearity error | <3.0 % |
Repeatability error | A (absorbency of light) <0.005 |
Test angle | 60° |
Gloss aperture | 2 × 3 mm |
Measurement range | 0 to 1000 GU |
Repeatability | 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU) |
Sample (size) length | 38×70 mm |
Measuring range | (1-500) mN.m (divided into 7 small ranges) |
Indication error | 0.02 |
Test speed | (200° ± 20°)/ min |
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
System | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm |
Light source | D65 as illuminating source |
Zero drift | ≤ 0.1 % |
Sample (size) length | Diameter ≥30 mm, Thickness ≤ 40 mm |
Measurement mode | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b |
Stability | ≤ 0.1 within 30 min |
Accuracy | Chromaticity co-ordinate 0.0001 |