Soil nutrient tester TSNA-A10

Soil nutrient tester TSNA-A10 with microprocessor controlled technology measures nutrient values in % and gives accurate test results. Its LCD touch display shows all test parameters, test results, which can be printed out using built-in printer. The optical filter present in the nutrient analyzer acts as light source, its silicon semiconductor acts as signal receiver system with 100000 hours of work life.

Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Wavelength range Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm, Orange light: 590 ± 2 nm
Sensitivity Red light: ≥ 4.5 × 10<sup>-5</sup> , Blue light: ≥ 3.17 × 10<sup>-3</sup> , Green light: ≥ 2.35 × 10<sup>-3</sup> , Orange light: ≥ 2.13 × 10<sup>-3</sup>
Moisture measure range A: humidity 0 to 100 %, B: Accuracy: ±3 %
Measurement time (for soil N, P, K) ≤30 min<br/> 5 pcs soil samples at one time ≤50 min (including pretreatment time)
Soil moisture mode
  • Moisture content rate testing range: 0 to 100 %
  • Moisture unit: % (m<sup>3</sup>/m<sup>3</sup>)
  • Accuracy: ± 2 %
pH mode
  • pH Measurement range: 1 to 14 pH
  • pH Accuracy: ± 0.1
Conductivity mode
  • Conductivity Measurement range: 0.01 % to 1.00 %
  • Conductivity Accuracy: ± 5 %
Dimension 340 × 280 × 100 mm
Gross Weight 15 kg
Power supply AC 180 to 240 V, 50 Hz
  • LCD display touch control
  • Microprocessor controlled technology
  • Built-in thermal printer
  • Automatic temperature calibration system for organic phosphorous testing
  • Excellent shock resistant
  • Digital circuit programmed design
Reagent as per requirement/need

It finds best application in quantitative analysis of to N, P, K, organic matter, pH, trace elements, salinity of soil, fertilizer & other samples.

Measuring range 0 to 100 kPa
Resolution 0.01 kPa
Accuracy ± 1 kPa
Soil temperature measuring range -55 to 105°C
Measurement range 0 to 90 %
Resolution 0.1 or 0.01
Accuracy ± 5 % n (non-saturation condition)
Needle 235 mm
Salinity Measurement range 0.00 to 19.99 ms/cm
Measuring accuracy EC ± 2% full scale
Temperature Measurement range -5 to 50°C
Temperature accuracy ± 0.5°C
Maximum load 100 kg ( kg and N can be switched automatically)
Resolution 0.01 g
Accuracy ± 0.5 %
Measuring depth 0 to 450 mm
Maximum load 100 kg ( kg and N can be switched automatically)
Resolution 0.01 g
Accuracy ± 0.5 %
Measuring depth 0 to 40 mm
Measurement range 0 to 80 %
Resolution 0.1
Accuracy ± 2 % n (non-saturation condition)
Needle 280 mm
Measurement range 0 to 60 %
Resolution 0.1
Accuracy ± 5 % n (non-saturation condition)
Needle 280 mm
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source
Zero drift ≤ 0.1 %
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min
Accuracy Chromaticity co-ordinate 0.0001
Sample (size) length 38×70 mm
Measuring range (1-500) mN.m (divided into 7 small ranges)
Indication error 0.02
Test speed (200° ± 20°)/ min
Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min </br> -30℃ to -40℃ around 2.5 ℃/min </br> -40℃ to -70℃ around 2.0 ℃/min</br>
Max dimension L × W × H 910 × 510 × 860 mm
Test arm weight 2.5 N
Additional Loads 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler 150 mm
Abrasion stroke 40 ± 0.2 M
Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control
Display LED display
Salinity Measurement range 0.00 to 19.99 ms/cm
Measuring accuracy EC ± 2% full scale
Temperature Measurement range -5 to 50°C
Temperature accuracy ± 0.5°C
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Vacuum degree 0 to 90 KPa
Accuracy 1 % FS
Resolution 0.1 KPa
Vacuum chamber effective size 270 × 210 mm
The maximum temperature 300°C
Temperature fluctuation Within ± 0.5°C
Temperature uniformity Within ± 1°C
Rotate speed of the turntable 11 r/min to 12r/min, turntable dimension diameter: 285 mm
Resolution 0.1 % O2
Measuring range 0 to 100 % O2
Precision ± 0.4 % O2
Response time < 10 S
Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU
Repeatability 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)