Internal Ply bond Tester TP-J11

Internal Ply bond Tester TP-J11 is used to test the Z direction tensile internal (interlayer bonding) bonding strength of various paperboards. The instrument design is based on a falling pendulum which creates a high speed impact on a paper specimen. The test paper sample is impacted by certain angle and weight. The energy absorbed by the paper indicates the internal bonding strength of that paper.

Measuring range
Capacity A: 20 to 500 J/m2 B: 500 to 1000 J/m2
Resolution
Indication error
Tearing arm
Tearing angle
Chips distance
Clamp- paper
Resection length
Tearing distance
Frictional resistance
Pyramid dimension
Platen Size
Operating stroke
Compression speed
Impact angle 90°
Unit Lb-ft/in2  J/m2
Error A: ± 1 J/m2 B: ± 2 J/m2
Sample amount 5 pcs
Speed adjustment range
Track & force speed in stacking test
Test area
Area differential pressure
Inner diameter of grip ring
Dimension 700×340×600 mm
Weight 92    g
Power supply
  • 90° impact angle
  • Tests 5 sample at a time
  • LCD digital display
  • Magnetic pendulum release

Internal ply bond tester is used in paper, corrugated paper & packaging industry.

Measuring range 10 to 1000 mN
Division value 1 mN
Accuracy ± 1%
Indicating Error ≤ 0.5
Measuring range 0 to 1000 mN
Resolution 0.1 mN
Indication error ± 1 %
Tearing arm 104 ± 1 mm
Sample (size) length 90 to 200 mm
Sample width 15 mm, 25 mm, 50mm
Measuring range 0 to 30, 0 to 100 N,0 to 300 N
Accuracy ± 1 %
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source
Zero drift ≤ 0.1 %
Sample (size) length 0 to 200 mm adjustable
Sample width 15 mm
Measuring range 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy ± 1 %
Sample width 15 mm
Sample maximum length 300 mm
Parallelism ≤ 0.1 mm
Dimension 240×520×70 mm
Measuring range 0 to 4 mm
Accuracy 0.01 or 0.001 mm
Gauge Analogue gauge display
Contact pressure (to create false weight) 100 ± 10 kPa
Measurement range 5 to 500 N, 50 to 3000 N
Resolution 1 N
Accuracy ± 1 %
Variability ≤ 1 %
Measurement range 0 to 100° SR
Sealed testing speed 100 ± 10 mm/s
Volume of distilled water 1000 ± 5 ml
Draining time 149 ± 1 s
Measuring scope 0 to 99999 s
Folding angle 135° ± 2°
Tensile scope 4.9 to 14.7 N
Folding head suture size 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm
Measurement range 0 to 5600 kPa
Accuracy ± 0.5 % F.S.
Compression speed 170 ± 15 ml/min
Clamp pressure ≥ 690 kPa
Measuring scope ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
Accuracy ±0.1 s within 300 s
Vacuum system volume (ml) Bigger volume: 380 ± 1<br/> Smaller volume: 38 ± 1
Contact pressure 100 ± 2 kPa
Measuring range 0 to 1000 ml/min
Test area 10 ± 0.02 cm2
Area differential pressure 1 ± 0.01 kPa
Inner diameter of grip ring 35.68 ± 0.05 mm
Measuring range A (1 to 6) J indicating error ± 0.05 J<br/> B (1 to 12) J indicating error ± 0.05 J<br/> C (1 to 24) J indicating error ± 0.05 J<br/> D (1 to 48) J indicating error ± 0.05 J<br/> The indicating errors w.r.t measurement range of 20 to 80 %
Frictional resistance <0.25 J
Pyramid dimension Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm
Dimension 800×470×840 mm
Sample (size) length 38×70 mm
Measuring range (1-500) mN.m (divided into 7 small ranges)
Indication error 0.02
Test speed (200° ± 20°)/ min
Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU
Repeatability 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)
Test arm weight 2.5 N
Additional Loads 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler 150 mm
Abrasion stroke 40 ± 0.2 M
Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min </br> -30℃ to -40℃ around 2.5 ℃/min </br> -40℃ to -70℃ around 2.0 ℃/min</br>
Max dimension L × W × H 910 × 510 × 860 mm
Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control
Display LED display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 0 to 30 S
Hardness indication Analogue display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 1 to 30 S
Hardness indication Digital display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Brinell hardness test 306, 613, 1839 N
Vickers hardness test 294, 588, 980 N
Vacuum degree 0 to 90 KPa
Accuracy 1 % FS
Resolution 0.1 KPa
Vacuum chamber effective size 270 × 210 mm
The maximum temperature 300°C
Temperature fluctuation Within ± 0.5°C
Temperature uniformity Within ± 1°C
Rotate speed of the turntable 11 r/min to 12r/min, turntable dimension diameter: 285 mm
Resolution 0.1 % O2
Measuring range 0 to 100 % O2
Precision ± 0.4 % O2
Response time < 10 S
Salinity Measurement range 0.00 to 19.99 ms/cm
Measuring accuracy EC ± 2% full scale
Temperature Measurement range -5 to 50°C
Temperature accuracy ± 0.5°C
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005