Pulp beating (refining) freeness tester TP-C10

Pulp beating (refining) freeness tester TP-C10 is used to measure the rate of dilution of pulp suspended water materials and to determine de-watering time. It is adopted with spring pre-tightening mechanism keeps the rubber sealing ring of the sealing hammer body in contact with the bottom of the water filtering tube. This increases the sealing performance of the sealing hammer body.

Measurement range 0 to 100° SR
Slider weight
Slider size
Testing accuracy
Dimension of working plate
Speed of slider
Slider stroke
Specimen size
Division value
Number of specimen holders
Metal Cylinder inner area
Metal Cylinder height
Metal roller width
Metal roller weight
Absorbency paper
Absorbency speed
Sealed testing speed 100 ± 10 mm/s
Volume of distilled water 1000 ± 5 ml
Sample diameter
Sample error
Sample Thickness
Draining time 149 ± 1 s
Residual water volume 7.85 to 8 ml
Hydraulic pressure >0.3 MPa
Dimension 450×250×1100 mm
Net Weight 40 kg
  • Use of Schopper-Riegler test method for designing
  • Adopted with spring pre-tightening mechanism
  • Measurement range 0 to 100° SR
  • Equipped with manual compression seal cone
  • Simple user–friendly operations

Pulp beating freeness tester has applications in pulp & paper industry, packaging industry.

Measurement range 5 to 500 N, 50 to 3000 N
Resolution 1 N
Accuracy ± 1 %
Variability ≤ 1 %
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min
Accuracy Chromaticity co-ordinate 0.0001
Measuring range 0.1 to 10 kN
Indication error < ± 1%
Platen Size 500×500 mm (customized)
Operating stroke 500 mm (customized)
Measuring range 1 to 50 kN
Indication error < ± 1%
Platen Size 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)
Operating stroke 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)
Measuring range A (1 to 6) J indicating error ± 0.05 J<br/> B (1 to 12) J indicating error ± 0.05 J<br/> C (1 to 24) J indicating error ± 0.05 J<br/> D (1 to 48) J indicating error ± 0.05 J<br/> The indicating errors w.r.t measurement range of 20 to 80 %
Frictional resistance <0.25 J
Pyramid dimension Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm
Dimension 800×470×840 mm
Measuring range 0 to 1000 ml/min
Test area 10 ± 0.02 cm2
Area differential pressure 1 ± 0.01 kPa
Inner diameter of grip ring 35.68 ± 0.05 mm
Measuring scope 0 to 99999 s
Folding angle 135° ± 2°
Tensile scope 4.9 to 14.7 N
Folding head suture size 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm
Sample size (L*B) 230×50 mm (can join short samples together)
Rub pressure 20 ± 0.2 N
Friction speed 43 times / min
Friction area (L*B) 155×50 mm
Sample (size) length 38×70 mm
Measuring range (1-500) mN.m (divided into 7 small ranges)
Indication error 0.02
Test speed (200° ± 20°)/ min
Measurement range 0 to 1600 kPa
Accuracy ± 0.5 % F.S.
Compression speed 95 ± 5 ml/min
Clamp pressure ≥ 430 kPa
Measuring range 0 to 20 mm
Accuracy 0.01 mm
Gauge Analogue gauge display
Contact pressure (to create false weight) 20 ± 0.5 kPa
Measurement range 0 to 5600 kPa
Accuracy ± 0.5 % F.S.
Compression speed 170 ± 15 ml/min
Clamp pressure ≥ 690 kPa
Capacity A: 20 to 500 J/m2 B: 500 to 1000 J/m2
Impact angle 90°
Unit Lb-ft/in2  J/m2
Error A: ± 1 J/m2 B: ± 2 J/m2
Measurement range 0.01 to 10 N
Slider weight 200 g
Slider size 63×63 mm
Testing accuracy ± 2 %
Capacity 10 -16000 mN
Resolution 0.1 mN
Tearing arm 104 ± 1 mm
Tearing angle 27.5° ± 5°
Sample (size) length 38×70 mm
Measuring range (1-500) mN.m (divided into 7 small ranges)
Indication error 0.02
Test speed (200° ± 20°)/ min
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min
Accuracy Chromaticity co-ordinate 0.0001
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source
Zero drift ≤ 0.1 %
Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control
Display LED display
Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min </br> -30℃ to -40℃ around 2.5 ℃/min </br> -40℃ to -70℃ around 2.0 ℃/min</br>
Max dimension L × W × H 910 × 510 × 860 mm
Test arm weight 2.5 N
Additional Loads 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler 150 mm
Abrasion stroke 40 ± 0.2 M
Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU
Repeatability 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)
The maximum temperature 300°C
Temperature fluctuation Within ± 0.5°C
Temperature uniformity Within ± 1°C
Rotate speed of the turntable 11 r/min to 12r/min, turntable dimension diameter: 285 mm
Resolution 0.1 % O2
Measuring range 0 to 100 % O2
Precision ± 0.4 % O2
Response time < 10 S
Vacuum degree 0 to 90 KPa
Accuracy 1 % FS
Resolution 0.1 KPa
Vacuum chamber effective size 270 × 210 mm
Salinity Measurement range 0.00 to 19.99 ms/cm
Measuring accuracy EC ± 2% full scale
Temperature Measurement range -5 to 50°C
Temperature accuracy ± 0.5°C
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005