Electronic Tearing tester TP-J21

Electronic Tearing tester TP-J21 is adopted with advanced and supporting components, single-chip microcomputer and has reasonable structure and multi- function design. The variety of parameters included in electronic tester are standard test, conversion, adjustment, display, memory, print and other functions. This electronic tearing resistance tester is suitable for all kinds of paper and some kinds of cardboards.

Measuring range
Capacity 10 -16000 mN
Resolution 0.1 mN
Indication error
Tearing arm 104 ± 1 mm
Tearing angle 27.5° ± 5°
Chips distance 180 mm
Clamp- paper 2.8 ± 0.3 mm
Resection length 20 ± 0.5 mm
Tearing distance
Frictional resistance
Pyramid dimension
Platen Size
Operating stroke
Compression speed
Impact angle
Unit
Error
Sample amount
Speed adjustment range
Track & force speed in stacking test
Test area
Area differential pressure
Inner diameter of grip ring
Dimension
Weight 20 kg
Power supply
  • High precision angle sensor to ensure rapid collection of data
  • Micro-printer, easy to print test report
  • Flexible configurations to reach different functions
  • Touch screen display
  • Connected to PC for data transfer
  • Compact structure design
  • Easy for maintenance

Electronic Tearing tester is used to test tearing strength of paper material, paper and sheets, cardboards etc. in paper and packaging, textile industry.

Measuring range 1 to 50 kN
Indication error < ± 1%
Platen Size 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)
Operating stroke 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)
Sample diameter 125 mm
Sample error ± 0.2 mm
Sample Thickness 0.1 to 1.0 mm
Dimension 240×288×435 mm
Measuring range 10 to 1000 mN
Division value 1 mN
Accuracy ± 1%
Indicating Error ≤ 0.5
Measuring range 0 to 4 mm
Accuracy 0.01 or 0.001 mm
Gauge Analogue gauge display
Contact pressure (to create false weight) 100 ± 10 kPa
Measurement range 5 to 500 N, 50 to 3000 N
Resolution 1 N
Accuracy ± 1 %
Variability ≤ 1 %
Metal Cylinder inner area (100 ± 0.2) cm2
Metal Cylinder height 50 mm
Metal roller width (200 ± 0..5) mm
Metal roller weight (10 ± 0.5) kg
Sample (size) length 180 mm (180, 150, 100, 90, 50 mm adjustable)
Sample width 15 mm
Measuring range 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy ± 1 %
Sample size (L*B) 230×50 mm (can join short samples together)
Rub pressure 20 ± 0.2 N
Friction speed 43 times / min
Friction area (L*B) 155×50 mm
Sample (size) length 0 to 200 mm adjustable
Sample width 15 mm
Measuring range 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy ± 1 %
Capacity A: 20 to 500 J/m2 B: 500 to 1000 J/m2
Impact angle 90°
Unit Lb-ft/in2  J/m2
Error A: ± 1 J/m2 B: ± 2 J/m2
Measuring range A (1 to 6) J indicating error ± 0.05 J<br/> B (1 to 12) J indicating error ± 0.05 J<br/> C (1 to 24) J indicating error ± 0.05 J<br/> D (1 to 48) J indicating error ± 0.05 J<br/> The indicating errors w.r.t measurement range of 20 to 80 %
Frictional resistance <0.25 J
Pyramid dimension Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm
Dimension 800×470×840 mm
Testing speed 200° ± 20° / min
Test range 1 to 10000 mN
Indicating Error ± 1 %
Testing length 5, 10, 15, 20, 25, 50 mm
Measuring scope 0 to 99999 s
Folding angle 135° ± 2°
Tensile scope 4.9 to 14.7 N
Folding head suture size 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm
Measurement range 0 to 100° SR
Sealed testing speed 100 ± 10 mm/s
Volume of distilled water 1000 ± 5 ml
Draining time 149 ± 1 s
Measuring range 0 to 20 mm
Accuracy 0.01 mm
Gauge Analogue gauge display
Contact pressure (to create false weight) 20 ± 0.5 kPa
Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU
Repeatability 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)
Test arm weight 2.5 N
Additional Loads 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler 150 mm
Abrasion stroke 40 ± 0.2 M
Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control
Display LED display
Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min </br> -30℃ to -40℃ around 2.5 ℃/min </br> -40℃ to -70℃ around 2.0 ℃/min</br>
Max dimension L × W × H 910 × 510 × 860 mm
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 1 to 30 S
Hardness indication Digital display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 0 to 30 S
Hardness indication Analogue display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Brinell hardness test 306, 613, 1839 N
Vickers hardness test 294, 588, 980 N
Resolution 0.1 % O2
Measuring range 0 to 100 % O2
Precision ± 0.4 % O2
Response time < 10 S
The maximum temperature 300°C
Temperature fluctuation Within ± 0.5°C
Temperature uniformity Within ± 1°C
Rotate speed of the turntable 11 r/min to 12r/min, turntable dimension diameter: 285 mm
Vacuum degree 0 to 90 KPa
Accuracy 1 % FS
Resolution 0.1 KPa
Vacuum chamber effective size 270 × 210 mm
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Salinity Measurement range 0.00 to 19.99 ms/cm
Measuring accuracy EC ± 2% full scale
Temperature Measurement range -5 to 50°C