No rotor rheometer TNRR-A10

TNRR-A10 is a No rotor rheometer where rubber sample is enclosed in mold cavity, maintained at test temperature. The mold cavity comes in two parts, where lower part (swing oscillations) determines strain as the reaction torque of the mold cavity (force). The PID controlled microprocessor technology controls and detects change in temperature. LCD screen display the real vulcanization curve and temperature curve, adjust the test data, store test results.

Test arm weight
Additional Loads
Idler
Abrasion stroke
Horizontal displacement
Stroke
Grips lateral displacement
Idler wheel speed
Measurement mode
Specimen size
Emery cloth specifications
Shift screw
Limit rotation
Set rotation
Return form
Net Weight
Dimension
Control temperature range
Temperature tester Room temperature to 200°C
Temperature display resolution 0.1°C
Temperature control accuracy ≤ ± 0.3°C
Calibration accuracy
Rotor speed 100 times/ min
Die cavity frequency 1.7 Hz
Sway angle ± 0.5°, ± 1°, ± 3°
Air compression 0.5 MPa to 0.65 MPa
Ambient temperature 0 to 35°C
Test result Printed date, time, temperature, vulcanization curve, temperature curve ML, MH, ts1, ts2, t10, t50, Vc1, Vc2
Display Windows 7 + software
Speed accuracy
Torque range 0 to 5 NM, 0 to 10 NM, 0 to 20 NM
Torque resolution 0.001 NM
Printer connection
Content printed
Product dimension 1310 × 560 × 620 mm
Weight 250 kg
Power supply Single phase, 220 V ± 10%, 50 Hz
  • PID controlled microprocessor technology
  • LCD Display
  • Use of highly imported precision sensors
  • Statistics, analysis, storage and comparison functions
  • Can print automatic processing, calculations results
  • Non curing viscometer monolithic rotor controlled
  • User-friendly design appearance, easy to operate
  • Supplied with data acquisition system
  • Finds the vulcanization time for gelatin

No rotor rheometer is used to test vulcanization characteristics of rubber material across rubber industry for quality & research.

Control temperature range Normal temperature to 200°C
Temperature display resolution 0.01°C
Temperature control accuracy ± 0.3°
Calibration accuracy Mooney value ± 0.5
Temperature range -60°C to 0°C
Temperature accuracy ± 0.5°C
Impact speed 2 m/s ± 0.2 m/s
Temperature fluctuation <± 0.5°C
Temperature range RT 50° to 300°
Temperature accuracy ± 1°
Measuring range 0.01 to 25 mm
Accuracy ± 0.01 mm
Test arm weight 2.5 N
Additional Loads 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler 150 mm
Abrasion stroke 40 ± 0.2 M
Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min </br> -30℃ to -40℃ around 2.5 ℃/min </br> -40℃ to -70℃ around 2.0 ℃/min</br>
Max dimension L × W × H 910 × 510 × 860 mm
Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control
Display LED display
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Salinity Measurement range 0.00 to 19.99 ms/cm
Measuring accuracy EC ± 2% full scale
Temperature Measurement range -5 to 50°C
Temperature accuracy ± 0.5°C
Sample (size) length 38×70 mm
Measuring range (1-500) mN.m (divided into 7 small ranges)
Indication error 0.02
Test speed (200° ± 20°)/ min
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min
Accuracy Chromaticity co-ordinate 0.0001
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source
Zero drift ≤ 0.1 %
Test arm weight 2.5 N
Additional Loads 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler 150 mm
Abrasion stroke 40 ± 0.2 M
Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min </br> -30℃ to -40℃ around 2.5 ℃/min </br> -40℃ to -70℃ around 2.0 ℃/min</br>
Max dimension L × W × H 910 × 510 × 860 mm
Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control
Display LED display
Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU
Repeatability 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 0 to 30 S
Hardness indication Analogue display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Brinell hardness test 306, 613, 1839 N
Vickers hardness test 294, 588, 980 N
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 1 to 30 S
Hardness indication Digital display