Soil water hardness meter TSHM-A10

Soil water hardness meter TSHM-A10 comes in handheld design is adopted with theoretical value pressure gauge kg/cm2 to directly measure the soil hardness. Hardness meter used in soil property survey, for testing soil permeability and aeration. Provides accurate reliable results.

Maximum load 100 kg ( kg and N can be switched automatically)
Resolution 0.01 g
Accuracy ± 0.5 %
Measuring depth 0 to 40 mm
Hardness indication range 0 to 500 kg/ cm<sup>2</sup>
Environmental temperature 0 to 60°C
Allowable overload 1.5
Memory storage
Power supply mode 5 Nickel Cyanogen
Battery capacity Continuous operated battery, 6 to 8 hrs
Gross weight 2 kg
Power supply Chargeable AC 100 to 240 voltage
  • Analog display
  • Easy to clean probe
  • Durable pin pointer for measurement
  • Manual adjustment for zero value

Used for soil water hardness measurement of dry to normal & moist soil for quality analysis & testing purpose.

Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Salinity Measurement range 0.00 to 19.99 ms/cm
Measuring accuracy EC ± 2% full scale
Temperature Measurement range -5 to 50°C
Temperature accuracy ± 0.5°C
Measurement range 0 to 60 %
Resolution 0.1
Accuracy ± 5 % n (non-saturation condition)
Needle 280 mm
Measuring range 0 to 100 kPa
Resolution 0.01 kPa
Accuracy ± 1 kPa
Soil temperature measuring range -55 to 105°C
Measurement range 0 to 90 %
Resolution 0.1 or 0.01
Accuracy ± 5 % n (non-saturation condition)
Needle 235 mm
Maximum load 100 kg ( kg and N can be switched automatically)
Resolution 0.01 g
Accuracy ± 0.5 %
Measuring depth 0 to 450 mm
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Measurement range 0 to 80 %
Resolution 0.1
Accuracy ± 2 % n (non-saturation condition)
Needle 280 mm
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 0 to 30 S
Hardness indication Analogue display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 1 to 30 S
Hardness indication Digital display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Brinell hardness test 306, 613, 1839 N
Vickers hardness test 294, 588, 980 N
Resolution 0.1 % O2
Measuring range 0 to 100 % O2
Precision ± 0.4 % O2
Response time < 10 S
The maximum temperature 300°C
Temperature fluctuation Within ± 0.5°C
Temperature uniformity Within ± 1°C
Rotate speed of the turntable 11 r/min to 12r/min, turntable dimension diameter: 285 mm
Vacuum degree 0 to 90 KPa
Accuracy 1 % FS
Resolution 0.1 KPa
Vacuum chamber effective size 270 × 210 mm
Test arm weight 2.5 N
Additional Loads 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler 150 mm
Abrasion stroke 40 ± 0.2 M
Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control
Display LED display
Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min </br> -30℃ to -40℃ around 2.5 ℃/min </br> -40℃ to -70℃ around 2.0 ℃/min</br>
Max dimension L × W × H 910 × 510 × 860 mm
Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU
Repeatability 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Salinity Measurement range 0.00 to 19.99 ms/cm
Measuring accuracy EC ± 2% full scale
Temperature Measurement range -5 to 50°C
Temperature accuracy ± 0.5°C