Coefficient of friction tester TP-D10

Coefficient of friction tester TP-D10 is used in testing the static & kinetic friction coefficient of plastic films and sheet. Tester is designed in accordance with ISO 8295 standard. It is supported by professional software to print single or group results, reports and curves automatically.

Measurement range 0.01 to 10 N
Slider weight 200 g
Slider size 63×63 mm
Testing accuracy ± 2 %
Dimension of working plate 170×225 mm
Speed of slider 100 ± 1 0mm/min
Slider stroke Max 100 mm (adjustable)
Specimen size
Division value
Number of specimen holders
Metal Cylinder inner area
Metal Cylinder height
Metal roller width
Metal roller weight
Absorbency paper
Absorbency speed
Sealed testing speed
Volume of distilled water
Sample diameter
Sample error
Sample Thickness
Draining time
Residual water volume
Hydraulic pressure
Dimension
Net Weight
  • Microprocessor controlled computer system
  • Equipped with build-in mini printer
  • Quick start options for staring new test
  • Simultaneously measures kinetic & static coefficients of friction
  • LCD screen display
  • Easy to use

Coefficient of friction tester is used to test kinetic and static coefficient of friction samples, materials used in paper & cardboard industry.

Measuring range 0 to 20 mm
Accuracy 0.01 mm
Gauge Analogue gauge display
Contact pressure (to create false weight) 20 ± 0.5 kPa
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min
Accuracy Chromaticity co-ordinate 0.0001
Sample (size) length 90 to 200 mm
Sample width 15 mm, 25 mm, 50mm
Measuring range 0 to 30, 0 to 100 N,0 to 300 N
Accuracy ± 1 %
Measuring range 0 to 1000 mN
Resolution 0.1 mN
Indication error ± 1 %
Tearing arm 104 ± 1 mm
Sample (size) length 38×70 mm
Measuring range (1-500) mN.m (divided into 7 small ranges)
Indication error 0.02
Test speed (200° ± 20°)/ min
Measurement range 0 to 200 mm
Specimen size 15×250 mm
Division value 1 mm
Number of specimen holders 5
Measurement range 0 to 1600 kPa
Accuracy ± 0.5 % F.S.
Compression speed 95 ± 5 ml/min
Clamp pressure ≥ 430 kPa
Sample (size) length 180 mm (180, 150, 100, 90, 50 mm adjustable)
Sample width 15 mm
Measuring range 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy ± 1 %
Sample size (L*B) 230×50 mm (can join short samples together)
Rub pressure 20 ± 0.2 N
Friction speed 43 times / min
Friction area (L*B) 155×50 mm
Measuring scope ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
Accuracy ±0.1 s within 300 s
Vacuum system volume (ml) Bigger volume: 380 ± 1<br/> Smaller volume: 38 ± 1
Contact pressure 100 ± 2 kPa
Measuring range A (1 to 6) J indicating error ± 0.05 J<br/> B (1 to 12) J indicating error ± 0.05 J<br/> C (1 to 24) J indicating error ± 0.05 J<br/> D (1 to 48) J indicating error ± 0.05 J<br/> The indicating errors w.r.t measurement range of 20 to 80 %
Frictional resistance <0.25 J
Pyramid dimension Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm
Dimension 800×470×840 mm
Metal Cylinder inner area (100 ± 0.2) cm2
Metal Cylinder height 50 mm
Metal roller width (200 ± 0..5) mm
Metal roller weight (10 ± 0.5) kg
Measuring range 1 to 50 kN
Indication error < ± 1%
Platen Size 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)
Operating stroke 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)
Capacity A: 20 to 500 J/m2 B: 500 to 1000 J/m2
Impact angle 90°
Unit Lb-ft/in2  J/m2
Error A: ± 1 J/m2 B: ± 2 J/m2
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source
Zero drift ≤ 0.1 %
Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min </br> -30℃ to -40℃ around 2.5 ℃/min </br> -40℃ to -70℃ around 2.0 ℃/min</br>
Max dimension L × W × H 910 × 510 × 860 mm
Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control
Display LED display
Test arm weight 2.5 N
Additional Loads 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler 150 mm
Abrasion stroke 40 ± 0.2 M
Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU
Repeatability 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Salinity Measurement range 0.00 to 19.99 ms/cm
Measuring accuracy EC ± 2% full scale
Temperature Measurement range -5 to 50°C
Temperature accuracy ± 0.5°C
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Brinell hardness test 306, 613, 1839 N
Vickers hardness test 294, 588, 980 N
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 0 to 30 S
Hardness indication Analogue display
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 1 to 30 S
Hardness indication Digital display
Resolution 0.1 % O2
Measuring range 0 to 100 % O2
Precision ± 0.4 % O2
Response time < 10 S
Vacuum degree 0 to 90 KPa
Accuracy 1 % FS
Resolution 0.1 KPa
Vacuum chamber effective size 270 × 210 mm
The maximum temperature 300°C
Temperature fluctuation Within ± 0.5°C
Temperature uniformity Within ± 1°C
Rotate speed of the turntable 11 r/min to 12r/min, turntable dimension diameter: 285 mm