Atomic Absorption Spectrophotometer LAAS-A21

Atomic Absorption spectrophotometer comes with flame, graphite furnace and hydride generation system to meet different customer demand. It consist of 1800/mm reticle large are grating monochromator and titanium burner to improve the analysis efficiency and accuracy of the flame. Atomic Absorption spectrophotometer has manual 3 lamp holder configuration & 3 independent lamp power supply for analysis.

Monochromator
Wavelength range 180 – 900 nm
Spectral Bandwidth 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Baseline drift ≤ ± 0.002 Abs / 30 min (Static) ≤ ± 0.005 Abs / 30 mins (Dynamic)
Grating groove density
Sample Volume
The volume of sample
Repeated Sampling Frequency
Cleaning and waste container volume
Absorbance Range 0 - 4 A
The Program
Temperature Range
Detector
Heating Mode
Temperature Control Method
Temperature Control
Resolution
Lamp holder ≤ 3 lamps automatic turret, automatic alignment
Lamp current adjustment range
Lamp power supply mode pulsed power supply
Optical System large 1800 /mm grating ruling, full closed optical system
Atomization Chamber Polymer explosion-proof spray chamber
Characteristics Volume
Characteristic concentration (Cu) 0.015 μg / mL / 1 %
Detection Limit
Detection Limit (Cu) 0.002 μg/mL
Background calibration ability
Burner Full titanium combustion head, 50 mm or 100 mm general combustion head
Nebulizer Atomizer efficient glass atomizer,can also be customized
Precision RSD ≤ 0.5 %
Ignition Type Microcomputer control, automatic ignition
Sprayer
Room Spray
Sample Tray
The Smallest Lincrement
Safety measures
Gas Control Automatic gas control system
Measurement Flame method, Hydride generation-Atomic absorption method
Concentration calculation Standard curve method(1 - 3 times curve), automatic fitting
The Cooling Water
The number of repeated measurements 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.
Print results Print the final stages of test data or analysis. The results can be exported into Excel worksheet.
Software Environment
Operating temperature
Working humidity
Power supply
Power (VAC)
Gross Weight
Weight
Dimension (L × W × H)
  • 1800 /mm reticle (dispersion rate) large area grating monochromator
  • High performance hollow cathode lamp
  • Titanium burner for the flame analysis
  • Polymer automization chamber
  • Automatic analysis for sensitivity and reproducibility
  • High precision automatic optical system
  • Flame, graphite furnace operating mode can be switched automatically
  • Light source 3 lamp holder
  • Convenient data processing & sharing & printing
  • Powerful software with automatic instrument and additional control

Atomic absorption spectrophotometer is widely used in analysis of elements from the mixture in scientific research, environmental science, metallurgy, agriculture & chemical industry, food, mining, and petrochemical, pharmaceutical industries.

Related Products of Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm
Wavelength repeatability ≤ 0.04 nm
Wavelength range 190 nm ~ 900 nm
Spectral bandwidth 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm
Wavelength accuracy ± 0.25 nm
Wavelength repeatability 0.15 nm
Wavelength range 190 - 900 nm
Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength accuracy ≤ ± 0.5 nm
Wavelength repeatability ≤ 0.3 nm(single direction)
Wavelength range 180 - 900 nm
Spectral Bandwidth 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Wavelength range 180 – 900 nm
Spectral Bandwidth 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Wavelength Range 900 nm to 2500 nm
Wavelength Accuracy ≤ 0.2
Wavelength Reproducibility ≤ 0.05
Bandwidth 8 nm

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 1 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Range 400 nm to 700 nm
Wavelength Interval 10 nm
Sensor High sensitivity silicon photodiode
Light Source LED
Wavelength Range 360 nm to 780 nm
Wavelength Pitch 10 nm
Sensor Silicon Photodiode Array
Grating Method Concave Grating
Illumination system d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination light source CLED
Sensor Dual light path sensor array

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm
Wavelength repeatability ≤ 0.04 nm
Wavelength range 190 - 900 nm
Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength accuracy ≤ ± 0.5 nm
Wavelength repeatability ≤ 0.3 nm(single direction)
Wavelength range 180 - 900 nm
Spectral Bandwidth 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm