Atomic Absorption spectrophotometer comes with flame, graphite furnace and hydride generation system to meet different customer demand. It consist of 1800/mm reticle large are grating monochromator and titanium burner to improve the analysis efficiency and accuracy of the flame. Atomic Absorption spectrophotometer has manual 3 lamp holder configuration & 3 independent lamp power supply for analysis.
| Wavelength range | 180 – 900 nm |
| Spectral Bandwidth | 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover) |
| Wavelength accuracy | ≤ 0.15 nm |
| Wavelength repeatability | ± 0.1 nm |
| Baseline drift | ≤ ± 0.002 Abs / 30 min (Static) ≤ ± 0.005 Abs / 30 mins (Dynamic) |
| Absorbance Range | 0 - 4 A |
| Lamp holder | ≤ 3 lamps automatic turret, automatic alignment |
| Lamp power supply mode | pulsed power supply |
| Optical System | large 1800 /mm grating ruling, full closed optical system |
| Atomization Chamber | Polymer explosion-proof spray chamber |
| Characteristic concentration (Cu) | 0.015 μg / mL / 1 % |
| Detection Limit (Cu) | 0.002 μg/mL |
| Burner | Full titanium combustion head, 50 mm or 100 mm general combustion head |
| Nebulizer | Atomizer efficient glass atomizer,can also be customized |
| Precision | RSD ≤ 0.5 % |
| Ignition Type | Microcomputer control, automatic ignition |
| Gas Control | Automatic gas control system |
| Measurement | Flame method, Hydride generation-Atomic absorption method |
| Concentration calculation | Standard curve method(1 - 3 times curve), automatic fitting |
| The number of repeated measurements | 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation. |
| Print results | Print the final stages of test data or analysis. The results can be exported into Excel worksheet. |
Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.
| Wavelength range | 180 – 900 nm |
| Spectral Bandwidth | 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting |
| Wavelength range | 180 - 900 nm |
| Spectral Bandwidth | 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting) |
| Wavelength range | 190 - 900 nm |
| Spectral Bandwidth | 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm |
| Working spectral range | 190 to 900 nm |
| Spectral Bandwith | 0.1, 0.2, 0.4, 1.0 and 2.0 nm |
| Wavelength accuracy | ± 0.15 nm |
| Wavelength range | 190 nm ~ 900 nm |
| Spectral bandwidth | 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm |
| Wavelength accuracy | ± 0.25 nm |
Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.
| Wavelength Range | 190 to 1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Optical System | Double beam, C-T monochromator,1200 L/mm holographic grating |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 0.5/1/2/4 nm |
| Wavelength Accuracy | ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 1.8 nm |
| Optical system | Double beam; 1200 lines/mm grating |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 1.0 to 5.0 nm (adjustable) |
| Optical system | Double beam, C-T monochromator, 1600 L/mm holographic grating |
| Wavelength Range | 190 to 1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Optical System | Double beam |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 1 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength Range | 190 ~ 1100 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 nm adjustable |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 0.5/1/2/4/5 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength range | 190 ~ 1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength accuracy | 0.5 nm |
| Wavelength Range | 190 to 1100 nm |
| Spectral Bandwidth | 1.0 nm |
| Optical System | Double beam |
We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.
| Wavelength | 260 nm and 280 nm; Fixed |
| Spectral resolution | ≤ 8 nm |
| Path length | 0.5 mm |
| Wavelength range | 190 to 850 nm |
| Wavelength accuracy | ± 1 nm |
| Wavelength Resolution | 2 nm (FWHM at Hg 546 nm) |
We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations
| Wavelength Range | 190 ~ 1100 nm |
| Spectral Bandwidth | 1 nm |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 1 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 0.5/1/2/4/5 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength Range | 190 ~ 1100 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 2 nm |
| Wavelength Range | 200 to 1000 nm |
| Spectral Bandwidth | 4.0 nm |
| Optical System | Single beam |
| Wavelength Range | 190 ~ 1100 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Range | 190 ~ 1100 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm |
| Wavelength Range | 190 ~ 1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength Range | 190 ~ 1100 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 4 nm |
| Wavelength Range | 190 ~ 1100 nm |
| Spectral Bandwidth | 0.5 nm, 1 nm, 2 nm, 4 nm adjustable |
Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.
| Photometry | Single Beam |
| Monochromatic Type | Czerny-Turner |
| Wavelength range | 340 to 1000nm |
| Photometry | Single Beam |
| Monochromatic Type | Czerny-Turner |
| Wavelength range | 325 to 1000nm |
| Wavelength Range | 325 ~ 1000 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 2 nm |
| Wavelength range | 320 to 1100 nm |
| Spectral bandwidth | 2.0 nm |
| Wavelength Accuracy | ± 0.8 nm |
| Illumination system | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
| Wavelength Range | 400 nm to 700 nm |
| Wavelength Interval | 10 nm |
| Sensor | High sensitivity silicon photodiode |
| Illumination system | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Size of integrated sphere | 15.2 cm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
| Illumination system | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
| Wavelength Range | 360 nm to 780 nm |
| Wavelength Pitch | 10 nm |
| Sensor | Silicon Photodiode Array |
| Illumination system | d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement |
| Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
| Reflect | 8º(diffused illumination, 8 degree viewing angle) |
| Optical Geometry | SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source |
| Standards | ISO7724-1, ASTM E1164, DIN5033 Teil7 |
| Optical Geometry | D/8 (diffused illumination,8° viewing), SCI (Specular Component Included), SCE (Specular Component Excluded) |
| Integrating Sphere Size | Φ 40 mm |
| Light Source | LED (Full band balanced LED) |
| Illumination | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03 |
| Sensor | Dual light path sensor array |
| Illumination | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.05 |
| Sensor | Photoelectric diode sensor |
| Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
| Sensor | High sensitivity silicon photodiode |
| Optical Geometry | D/8 (diffused illumination,8° viewing), Specular Component Included (SCI) |
| Integrating Sphere Size | Φ 40 mm |
| Light Source | LED (Full band balanced LED) |
| Illumination | Observation angles 2°/10°<br/> Illumination: d/8 (Diffused lighting, 8° observation angle)<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement<br/> |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04 |
| Sensor | Dual light path sensor array |
| Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
| Sensor | High sensitivity silicon photodiode |
| Illumination | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.05 |
| Sensor | Blue light enhanced sensor array |
| Illumination | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.04 |
| Sensor | Photoelectric diode sensor |
| Reflect | 8º(diffused illumination, 8 degree viewing angle) |
| Optical Geometry | SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source |
| Standards | ISO7724-1, ASTM E1164, DIN5033 Teil7 |
| Wavelength Range | 900 nm to 2500 nm |
| Wavelength Accuracy | ≤ 0.2 |
| Wavelength Reproducibility | ≤ 0.05 |
| Excitation Source | 150 W Xenon Lamp |
| Excitation Wavelength | 200 nm to 900 nm |
| Excitation Slit | 1 nm, 2 nm, 5 nm, 10 nm, 20 nm |
| Light source | 150 W Xenon lamp |
| Excitation wavelength | 200 nm to 900 nm |
| Emission wavelength | 200 nm to 900 nm |
| Light source | 150 W Xenon lamp |
| Excitation wavelength | 200 nm to 900 nm |
| Emission wavelength | 200 nm to 900 nm |
| Optical system | Double Beam, Grating 1200 lines/mm |
| Wavelength Range | 190 nm to 1100 nm |
| Spectral Bandwidth | 2 nm |
| Optical system | Double Beam, Grating 1200 lines/mm |
| Wavelength Range | 190 nm to 1100 nm |
| Spectral Bandwidth | 1 nm |
| Optical system | Double Beam, Grating 1200 lines/mm |
| Wavelength Range | 190 nm to 1100 nm |
| Spectral Bandwidth | 2 nm |
| Optical system | Double Beam, Grating 1200 lines/mm |
| Wavelength Range | 190 nm to 1100 nm |
| Spectral Bandwidth | 1 nm |