Fluorescence Spectrophotometer LFS-A12 consist of a high quality 150 W Xenon light source and photoelectric multiplier tube detectors for providing sufficient light intensity signal to detect sensitivity which ranges between 200 nm to 900 nm. Features fluorescence detection limit of ≤ 1×10-10 g/ml and Water Raman peak of S/N ≥ 150. It consists of the following characteristics, namely, high detection sensitivity, fast scanning speed, high dynamic range, fast 3D scanning, etc. The main principles includes measurement of absorption and fluorescence. Absorbance measurements can be taken via one or more wavelengths. The fluorescence unit increases the measuring range by 1000 for detecting DNA.
| Light source | 150 W Xenon lamp |
| Excitation wavelength | 200 nm to 900 nm |
| Emission wavelength | 200 nm to 900 nm |
| Excitation slit | 2 nm, 5 nm, 10 nm, 20 nm |
| Emission slit | 2 nm, 5 nm, 10 nm, 20 nm |
| Wavelength accuracy | ±1.0 nm |
| Wavelength repeatability | ≤ 0.5 nm |
| Signal-to-Noise Ratio | Raman peak of water (P-P): S/N ≥ 150 (10 nm Slit) |
| Detection limit | ≤1×10-10 g/ml (Quinine Sulphate Solution) |
| Linearity | γ ≥ 0.995 |
| Peak repeatability | ≤ 1.5% |
| Stability (10 min) Zero Drift | ±0.3 |
| Stability (10 min) Value Limit | ±1.5% |
| Wavelength scan speed | Multi-speed level, Maximum at 48000 nm/min |
| Photometric value | 0.00 to 10000.00 |
| Data interface | USB 2.0 |
| Maximum power consumption | 200 W |
| Power Source | AC 220 V/50 Hz; 110 V/60 Hz |
| Dimension | 380×445×310 mm |
| Net weight | 12 kg |
| Gross weight | 14 kg |
| Light source | 150 W Xenon lamp |
| Excitation wavelength | 200 nm to 900 nm |
| Emission wavelength | 200 nm to 900 nm |
| Excitation Source | 150 W Xenon Lamp |
| Excitation Wavelength | 200 nm to 900 nm |
| Excitation Slit | 1 nm, 2 nm, 5 nm, 10 nm, 20 nm |
Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 0.5/1/2/4/5 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength Range | 190 to 1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Optical System | Double beam |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 0.5/1/2/4 nm |
| Wavelength Accuracy | ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 1.8 nm |
| Optical system | Double beam; 1200 lines/mm grating |
| Wavelength Range | 190 ~ 1100 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 nm adjustable |
| Wavelength range | 190 ~ 1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength accuracy | 0.5 nm |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 1 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 1.0 to 5.0 nm (adjustable) |
| Optical system | Double beam, C-T monochromator, 1600 L/mm holographic grating |
| Wavelength Range | 190 to 1100 nm |
| Spectral Bandwidth | 1.0 nm |
| Optical System | Double beam |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength Range | 190 to 1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Optical System | Double beam, C-T monochromator,1200 L/mm holographic grating |
We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.
| Wavelength range | 190 to 850 nm |
| Wavelength accuracy | ± 1 nm |
| Wavelength Resolution | 2 nm (FWHM at Hg 546 nm) |
| Wavelength | 260 nm and 280 nm; Fixed |
| Spectral resolution | ≤ 8 nm |
| Path length | 0.5 mm |
We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 1 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength Range | 190 ~ 1100 nm |
| Spectral Bandwidth | 0.5 nm, 1 nm, 2 nm, 4 nm adjustable |
| Wavelength Range | 190 ~ 1100 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 4 nm |
| Wavelength Range | 200 to 1000 nm |
| Spectral Bandwidth | 4.0 nm |
| Optical System | Single beam |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 0.5/1/2/4/5 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength Range | 190 ~ 1100 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Range | 190 ~ 1100 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm |
| Wavelength Range | 190 ~ 1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Range | 190 ~ 1100 nm |
| Spectral Bandwidth | 1 nm |
| Wavelength Range | 190 ~ 1100 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 2 nm |
Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.
| Wavelength Range | 325 ~ 1000 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 2 nm |
| Photometry | Single Beam |
| Monochromatic Type | Czerny-Turner |
| Wavelength range | 325 to 1000nm |
| Photometry | Single Beam |
| Monochromatic Type | Czerny-Turner |
| Wavelength range | 340 to 1000nm |
| Wavelength range | 320 to 1100 nm |
| Spectral bandwidth | 2.0 nm |
| Wavelength Accuracy | ± 0.8 nm |
Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.
| Wavelength range | 180 - 900 nm |
| Spectral Bandwidth | 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting) |
| Wavelength range | 190 - 900 nm |
| Spectral Bandwidth | 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm |
| Working spectral range | 190 to 900 nm |
| Spectral Bandwith | 0.1, 0.2, 0.4, 1.0 and 2.0 nm |
| Wavelength accuracy | ± 0.15 nm |
| Wavelength range | 180 – 900 nm |
| Spectral Bandwidth | 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover) |
| Wavelength range | 180 – 900 nm |
| Spectral Bandwidth | 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting |
| Wavelength range | 190 nm ~ 900 nm |
| Spectral bandwidth | 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm |
| Wavelength accuracy | ± 0.25 nm |
| Illumination system | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Size of integrated sphere | 15.2 cm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
| Illumination system | d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement |
| Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
| Illumination system | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
| Illumination system | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
| Wavelength Range | 360 nm to 780 nm |
| Wavelength Pitch | 10 nm |
| Sensor | Silicon Photodiode Array |
| Wavelength Range | 400 nm to 700 nm |
| Wavelength Interval | 10 nm |
| Sensor | High sensitivity silicon photodiode |
| Reflect | 8º(diffused illumination, 8 degree viewing angle) |
| Optical Geometry | SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source |
| Standards | ISO7724-1, ASTM E1164, DIN5033 Teil7 |
| Reflect | 8º(diffused illumination, 8 degree viewing angle) |
| Optical Geometry | SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source |
| Standards | ISO7724-1, ASTM E1164, DIN5033 Teil7 |
| Illumination | Observation angles 2°/10°<br/> Illumination: d/8 (Diffused lighting, 8° observation angle)<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement<br/> |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04 |
| Sensor | Dual light path sensor array |
| Illumination | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.05 |
| Sensor | Blue light enhanced sensor array |
| Illumination | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.04 |
| Sensor | Photoelectric diode sensor |
| Optical Geometry | D/8 (diffused illumination,8° viewing), SCI (Specular Component Included), SCE (Specular Component Excluded) |
| Integrating Sphere Size | Φ 40 mm |
| Light Source | LED (Full band balanced LED) |
| Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
| Sensor | High sensitivity silicon photodiode |
| Illumination | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.05 |
| Sensor | Photoelectric diode sensor |
| Illumination | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03 |
| Sensor | Dual light path sensor array |
| Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
| Sensor | High sensitivity silicon photodiode |
| Optical Geometry | D/8 (diffused illumination,8° viewing), Specular Component Included (SCI) |
| Integrating Sphere Size | Φ 40 mm |
| Light Source | LED (Full band balanced LED) |
| Wavelength Range | 900 nm to 2500 nm |
| Wavelength Accuracy | ≤ 0.2 |
| Wavelength Reproducibility | ≤ 0.05 |
| Optical system | Double Beam, Grating 1200 lines/mm |
| Wavelength Range | 190 nm to 1100 nm |
| Spectral Bandwidth | 1 nm |
| Optical system | Double Beam, Grating 1200 lines/mm |
| Wavelength Range | 190 nm to 1100 nm |
| Spectral Bandwidth | 1 nm |
| Optical system | Double Beam, Grating 1200 lines/mm |
| Wavelength Range | 190 nm to 1100 nm |
| Spectral Bandwidth | 2 nm |
| Optical system | Double Beam, Grating 1200 lines/mm |
| Wavelength Range | 190 nm to 1100 nm |
| Spectral Bandwidth | 2 nm |