Single Beam UV-Vis Spectrophotometer LUS-C10 is a compact, table top unit, comprising Silicon photodiode detector, Tungsten and Deuterium lamp as light source. Features 200 nm to 1000 nm wavelength range, 4.0 nm bandwidth with automatic setting of wavelength, direct input by K, B factor for quantitative measurement of standard curve. Designed with single chip microcomputer control, LCD screen to display multiple sets of data, large memory storage, it provides rich measurement methods with high performance and reliability.

Wavelength Range 200 to 1000 nm
Spectral Bandwidth 4.0 nm
Optical System Single beam
Wavelength Accuracy ±0.2 nm
Wavelength Repeatability 0.2 nm
Wavelength Resolution 0.1 nm
Photometric Display Range -4 to 4 A
Photometric Mode T, A, C, E
Photometric Accuracy ±0.2% τ
Photometric Repeatability 0.2% τ
Light Source Tungsten lamp, Deuterium lamp
Stray Light ≤0.05% τ (220 nm NaI, 340 nm NaNO2)
Stability 0.001 A/h @500 nm
Noise ± 0.002 A @500 nm
Display LCD display (128*64 dots)
Baseline Flatness ± 0.001 A
Detector Silicon photodiode
Power Supply AC 220/110 V, 50/60 Hz
Dimensions (L×W×H) 460×330×210 mm
Net Weight 11 kg
  • Compact, table top, single beam designed UV-Vis spectrophotometer
  • Designed with silicon photodiode detector, tungsten and deuterium lamp as light source
  • Wide wavelength range of 200 nm to 1000 nm with automatic setting
  • LCD screen displays multiple sets of data
  • Maximum 10 point standard curve measurement function
  • Direct input by K, B factor for quantitative measurement of standard curve
  • Large memory space to store multiple sets of data and curve
  • Produce High performance and reliable results with user-friendly interface

Single Beam UV-Visible Spectrophotometer are used for analysis of band gap, optical coatings and thin films, quantitative analyses, kinetics, wavelength scanning, and DNA and Protein analysis across biological research, bio-industry, pharmaceutical analysis, pharmaceutical, teaching and research, environmental protection, food hygiene, clinical examination, health and epidemic prevention and other fields.

Related Products of Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Wavelength Range 190 ~ 1100 nm
Spectral Bandwidth 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability 0.2 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.5 nm
Wavelength Range 190 ~ 1100 nm
Spectral Bandwidth 0.5 nm, 1 nm, 2 nm, 4 nm adjustable
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 4 nm
Wavelength Accuracy ± 0.5 nm
Wavelength Range 190 ~ 1100 nm
Spectral Bandwidth 1.8 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability 0.2 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 1.8 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Range 190 ~ 1100 nm
Spectral Bandwidth 1 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability 0.2 nm
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 1 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Test angle -
Illumination d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.05
Sensor Blue light enhanced sensor array
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Test angle 60°

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength Range 900 nm to 2500 nm
Wavelength Accuracy ≤ 0.2
Wavelength Reproducibility ≤ 0.05
Bandwidth 8 nm

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Wavelength range 190 - 900 nm
Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength accuracy ≤ ± 0.5 nm
Wavelength repeatability ≤ 0.3 nm(single direction)
Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm
Wavelength repeatability ≤ 0.04 nm
Wavelength range 180 - 900 nm
Spectral Bandwidth 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm