Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 2 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 1 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 0.5/1/2/4/5 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Optical system | Double Beam, Grating 1200 lines/mm |
Wavelength Range | 190 nm to 1100 nm |
Spectral Bandwidth | 2 nm |
Wavelength Accuracy | ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all |
Optical system | Double Beam, Grating 1200 lines/mm |
Wavelength Range | 190 nm to 1100 nm |
Spectral Bandwidth | 1 nm |
Wavelength Accuracy | ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all |
Optical system | Double Beam, Grating 1200 lines/mm |
Wavelength Range | 190 nm to 1100 nm |
Spectral Bandwidth | 2 nm |
Wavelength Accuracy | ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all |
We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.
Wavelength range | 200 - 800 nm |
Path length | 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary) |
Wavelength accuracy | ± 1 nm |
Wavelength Resolution | ≤ 3 nm (FWHM at Hg 546 nm) |
Wavelength range | 230 nm, 260 nm, 280 nm |
Path length | 1.0 mm, 0.2 mm |
Minimum Sample size | 0.3 - 2.0 µl |
Absorbance range | 0.2 - 75A (10 mm equivalent absorbance) |
Wavelength range | 200 - 850 nm |
Path length | 1 mm, 2 mm, 5 mm, 10 mm |
Wavelength accuracy | ± 1 nm |
Wavelength Resolution | 2 nm (FWHM at Hg 546 nm) |
Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
Sensor | High sensitivity silicon photodiode |
Test angle | - |
Illumination | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.05 |
Sensor | Blue light enhanced sensor array |
Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
Sensor | High sensitivity silicon photodiode |
Test angle | 60° |
Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.
Wavelength Range | 325 ~ 1000 nm |
Setting Wavelength | Automatic |
Spectral Bandwidth | 2 nm |
Wavelength Accuracy | ± 1.0 nm |
Wavelength Range | 335 ~ 1000 nm |
Spectral Bandwidth | 4 nm |
Wavelength Accuracy | ± 2 nm |
Wavelength Repeatability | 1 nm |
Wavelength Range | 330 to 1000 nm |
Spectral Bandwidth | 5 nm |
Wavelength Accuracy | ± 2 nm |
Wavelength Repeatability | ≤ 1.0 nm |