Double Beam UV-Vis Spectrophotometer LUS-B10

Double Beam UV-Vis Spectrophotometer LUS-B10 is a compact, tabletop double beam designed UV-Vis spectrophotometer comprising Silicon photodiode detector, Tungsten and Deuterium lamp as light source. Equipped with wide wavelength range of 190 nm to 1100 nm, it offers 1.8 nm of bandwidth with automatic setting of wavelength. Designed with 6 inches LCD display, import source and receiver system, it provides rich measurement methods with high performance and reliability.

Wavelength Range 190 to 1100 nm
Spectral Bandwidth 1.8 nm
Optical System Double beam
Wavelength Accuracy ±0.3 nm
Wavelength Repeatability ≤0.1 nm
Wavelength Resolution 0.1 nm
Photometric Display Range -4 to 4 A
Photometric Mode T, A, C, E
Photometric Accuracy ±0.3% τ (0 to 100%τ) ± 0.002 A (0 to 0.5 A) ± 0.003 A (0.5 A to 1 A)
Photometric Repeatability 0.15% τ (0 to 100% τ) ± 0.001 A (0 to 0.5 A) ± 0.0015 A (0.5 A to 1 A)
Light Source Tungsten lamp, Deuterium lamp
Stray Light ≤0.03% τ (220 nm NaI, 340 nm NaNO<sub>2</sub>)
Stability 0.0005 A/h @500 nm
Noise ± 0.002 A @500 nm
Display 6 inches high brightness Blue LCD display
Baseline Flatness ± 0.001 A
Detector Silicon photodiode
Power Supply AC 220/110 V, 50/60 Hz
Dimensions (L×W×H) 560×450×230 mm
Net Weight 28 kg
  • Compact, tabletop double beam designed UV-Vis spectrophotometer
  • Silicon photodiode detector, Tungsten and Deuterium lamp as light source
  • Wide wavelength range of 190 nm to 1100 nm with automatic setting
  • 6 inches high brightness blue LCD display
  • Import source and receiver system
  • Measurement methods: wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination, dual-wavelength, three-wavelength, DNA protein measurements etc.
  • High performance and reliability with user-friendly interface

Double Beam UV-Visible Spectrophotometer are used for analysis of band gap, optical coatings and thin films, quantitative analyses, kinetics, wavelength scanning, and DNA and Protein analysis across biological research, bio-industry, pharmaceutical analysis, pharmaceutical, teaching and research, environmental protection, food hygiene, clinical examination, health and epidemic prevention and other fields.

Related Products of Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Wavelength range 190 ~ 1100 nm
Spectral bandwidth 2 nm
Wavelength accuracy 0.5 nm
Wavelength repeatability ≤ 0.2 nm
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 1.0 nm
Optical System Double beam
Wavelength Accuracy ±0.3 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 1.8 nm
Optical system Double beam; 1200 lines/mm grating
Wavelength accuracy ±0.1nm (D2 656.1nm), ±0.3nm @ all
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 1.8 nm
Optical System Double beam, C-T monochromator,1200 L/mm holographic grating
Wavelength Accuracy ±0.3 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 0.5 / 1.0 / 2.0 / 4.0 nm adjustable
Wavelength Accuracy ± 0.3 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 1.0 to 5.0 nm (adjustable)
Optical system Double beam, C-T monochromator, 1600 L/mm holographic grating
Wavelength accuracy ±0.3 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4 nm
Wavelength Accuracy ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range
Wavelength Repeatability ≤ 0.1 nm
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 1 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Wavelength range 200 - 800 nm
Path length 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy ± 1 nm
Wavelength Resolution ≤ 3 nm (FWHM at Hg 546 nm)
Wavelength range 200 - 850 nm
Path length 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy ± 1 nm
Wavelength Resolution 2 nm (FWHM at Hg 546 nm)
Wavelength range 230 nm, 260 nm, 280 nm
Path length 1.0 mm, 0.2 mm
Minimum Sample size 0.3 - 2.0 µl
Absorbance range 0.2 - 75A (10 mm equivalent absorbance)
Illumination d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.05
Sensor Blue light enhanced sensor array
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Test angle -
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Test angle 60°

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm
Excitation slit 2 nm, 5 nm, 10 nm, 20 nm
Excitation Source 150 W Xenon Lamp
Excitation Wavelength 200 nm to 900 nm
Excitation Slit 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Emission Slit 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm
Excitation slit 2 nm, 5 nm, 10 nm, 20 nm