Fluorescence Spectrophotometer LFS-A11

Fluorescence Spectrophotometer LFS-A11 is a high performance equipment with a 150 W Xenon Lamp for providing sufficient light intensity signal to detect sensitivity. It is built for maintaining best possible accuracy. It contains characteristics like Ultra scanning speed, ultra high resolution, and ultra-high wavelength accuracy to meet most of the measurements. Quantum yield is also available for this fluorescence spectrophotometer.

Excitation Source 150 W Xenon Lamp
Excitation Wavelength 200 nm to 900 nm
Excitation Slit 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Emission Slit 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Wavelength Accuracy ± 0.4 nm
Wavelength Repeatability ≤ 0.2 nm
Signal-to-Noise Ratio S/N ≥ 350 (P-P), S/N ≥ 1000 (RMS)
Limit ≤ 5 × 10<sup> -11</sup> g /ml(Quinine Sulfate Solution)
Linearity γ ≥ 0.995
Peak Repeatability ≤ 1.5 %
Wavelength Scan Speed Multi-speed Level, Maximum at 60000 nm / min
Minimum sample size 0.5 mL (Using a standard 10 mm square sample cell)
Octave filter Build in Octave filter
Photometric Quantity Range -9999 to 9999
Response Time Auto adjust (0.02 s, 0.1 s, 0.5 s, 1 s, 2 s, 4 s, 8 s )
Data Transportation USB 2.0
Power 200 W
Power Supply AC 220 V / 50 Hz, 110 V / 60 Hz
Dimension 610×460×365 mm
Net Weight 21 kg
Gross Weight 26 kg
  • Horizontal slit optical design with finite luminous detection efficiency and high SNR
  • Water Raman peak SNR better than 350: 1 (P-P) or 1000: 1 (RMS)
  • Standard 10 mm square sample cell utilizes minimum sample volume of 0.5 mL
  • Wavelength scanning speed is flexible and can reach up till 60000 nm / min
  • Adjustable bandwidth feature
  • Accessories are available for Fluorescence Quantum Yield
  • Software is versatile enough to offer functions like fluorescence 3D scanning, equal wavelength difference synchronous scanning, and equal wave number difference (constant energy difference) synchronous scanning
  • Synchronous scanning function require pro version software
  • Multiple accessories provided
  • Best quality assurance given by using 150 W Xenon Lamp, to provide sufficient light intensity signal to detect sensitivity
  • Unstable samples is analysed via built-in optical gate and built-in frequency filter
Accessory No. Accessory Name
1 Multi- function fluorescent sample rack holder
2 Base of other sample racks.
3 Membrane sample rack
4 Powder sample rack
5 Sample cell jacket
6 200 µL micro centrifuge tube accessory
7 Up conversion fluorescent accessory
8 Fluorescence Quantum Yield accessory

They can be widely applicable in material research, drug analysis, biochemical, scientific research clinical testing, water quality control, food safety testing and other areas covering quantity and quality analysis.

Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm
Excitation slit 2 nm, 5 nm, 10 nm, 20 nm
Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm
Excitation slit 2 nm, 5 nm, 10 nm, 20 nm
Wavelength Range 900 nm to 2500 nm
Wavelength Accuracy ≤ 0.2
Wavelength Reproducibility ≤ 0.05
Bandwidth 8 nm
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Test angle -
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Test angle 60°
Illumination d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.05
Sensor Blue light enhanced sensor array
Size of integrated sphere 40 mm, alvan diffused reflection surface coating

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Wavelength range 200 - 850 nm
Path length 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy ± 1 nm
Wavelength Resolution 2 nm (FWHM at Hg 546 nm)
Wavelength range 200 - 800 nm
Path length 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy ± 1 nm
Wavelength Resolution ≤ 3 nm (FWHM at Hg 546 nm)
Wavelength range 230 nm, 260 nm, 280 nm
Path length 1.0 mm, 0.2 mm
Minimum Sample size 0.3 - 2.0 µl
Absorbance range 0.2 - 75A (10 mm equivalent absorbance)
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 1 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all