| Illumination system |
d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement |
| Size of integrated sphere |
40 mm, alvan diffused reflection surface coating |
| Illumination light source |
CLED |
| Sensor |
Dual light path sensor array |
| Light source |
A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF |
| Wavelength range |
400-700 nm |
| Wavelength interval |
10 nm |
| Half spectral width |
5 nm |
| Reflectivity range & resolution |
0 to 200%, 0.01% |
| Observation Angle |
2°/10° |
| Measurement caliber |
|
| Measurement time interval |
0.5 s |
| Measurement time |
2 s |
| Measuring aperture |
25.5*10 mm (cuvette support) |
| Color space |
CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Transmittance, Hunterlab, Munsell Mi, CMYK |
| Color difference formula |
ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555
color classification |
| Other colorimetric indices |
WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger,Ganz, Stensby)<br/>
YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73),
Tint(ASTM E313,CIE,Ganz)<br/>
Metamerism index Milm, staining fastness, color fastness, APHA, Astm color, ISO illuminance, saybolt |
| Repeatability |
Transmittance: standard deviation within 0.08%<br/>
color values:ΔE*ab<=0.015 <br/> (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.03 |
| Color matching system |
|
| UV light source |
|
| Work temperature range |
0-45°C, relative humidity 80% or below (at 35°C), no condensation |
| Storage temperature range |
25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation |
| Battery capacity |
|
| Data being displayed |
Samples color values,color difference values/graph,pass/fail results,color error tendency,color value simulation, color difference values, display measurement area,history data color simulation,manual input standard sample, generate measurement report |
| Interface |
USB |
| Display |
|
| Data storage |
Mass storage (on PC) |
| Light source longevity |
5 years, 1.5 million tests |
| Dimension (L*W*H) |
475 × 340 × 150 mm |
| Weight |
7 kg |
- D/0 Diffused lighting illumination system
- CLED light source to guarantee the measurement speed & test accuracy
- 1.5 ml sample volume
- Double grating & double optical path splitting system
- SCI & SCE both includes lightening & observation conditions
- Connection to PC data storage , transmission
- UV enhanced silicon photodiode with up to 200% improved transmittance range
- ETC to ensure reliability & accuracy in every test measurement
- Performs glass and liquid color measurement
Transmittance spectrophotometer is used in the measurement of range of liquids and solvents like resins, solvents, oils etc. to be used in food, chemical, textile, life science industries.