Table top spectrophotometer LTS-A12

Table top spectrophotometer LTS-A12 has multiple measuring calibers with largest caliber of 25.4 mm, satisfies the measurement needs of samples of different size. It is possible to measure the color data of opaque samples and transmission and opacity of transparent or semi-transparent samples. Equipped with dual light path spectral analysis technology ensures precision and long-term stability of the instrument. The 8°/diffused illumination geometric design of lightning, provides full insight of the color data.

Illumination system d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere 15.2 cm, alvan diffused reflection surface coating
Illumination light source CLED
Sensor Dual light path sensor array
Light source A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF
Wavelength range 400-700 nm
Wavelength interval 10 nm
Half spectral width 5 nm
Reflectivity range & resolution 0 to 200%, 0.01%
Observation Angle
Measurement caliber LAV: large aperture: 2.54 cm (1 inch)<br/> MAV: middle aperture: 1.5 cm (0.6 inch)<br/> SAV: small aperture: 0.75cm× 1.0 cm (0.3 inch×0.4 inch)<br/> VSAV: very small aperture: 0.3 cm× 0.8 cm (0.12 inch× 0.31 inch)
Measurement time interval 2 s
Measurement time 2 s
Measuring aperture
Color space CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK
Color difference formula ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 color classification
Other colorimetric indices WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby)<br/> YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313,CIE,Ganz) Metamerism index Milm, adhesive/changing color fastness, ISO illuminance, 8 gloss, A density, T density
Repeatability light splitting reflectivity:standard deviation within 0.08%<br/> color values:ΔE*ab<=0.015 (<br/> After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.03
Color matching system
UV light source
Work temperature range 0 to 45°C, relative humidity 80% or below (at 35°C), no condensation
Storage temperature range 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation
Battery capacity
Data being displayed Samples color values,color difference values/graph,pass/fail results,color error tendency,color value simulation, display measurement area,history data color simulation,manual input standard sample generate measurement report
Interface USB
Display 5 inch TFT touch screen
Data storage 20000 test results
Light source longevity 10 years, 3 million tests
Dimension (L*W*H) 583 × 330 × 304 mm
Weight 18 kg
  • Dual light path spectral analysis technology
  • Manual fitting of white calibration board on measurement port
  • Four measurement calibers, maximum is 25.4 mm
  • Large display screen for easier measurement and settings
  • Flexible measurement fixtures
  • Simultaneously measures SCI and SCE
  • PC connection for data transmission, software, storage
  • Reflection and transmission measurement
  • Adjustable UV components (light source) percentage value

Table top spectrophotometer with multiple measuring calibers has applications in measurement of solid as well as liquid material at multiple calibration points.

Illumination system d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination light source CLED
Sensor Dual light path sensor array
Wavelength Range 400 nm to 700 nm
Wavelength Interval 10 nm
Sensor High sensitivity silicon photodiode
Light Source LED
Illumination system d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination light source CLED
Sensor Dual light path sensor array
Illumination system d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination light source CLED
Sensor Dual light path sensor array
Wavelength Range 360 nm to 780 nm
Wavelength Pitch 10 nm
Sensor Silicon Photodiode Array
Grating Method Concave Grating

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Wavelength range 200 - 850 nm
Path length 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy ± 1 nm
Wavelength Resolution 2 nm (FWHM at Hg 546 nm)
Wavelength range 230 nm, 260 nm, 280 nm
Path length 1.0 mm, 0.2 mm
Minimum Sample size 0.3 - 2.0 µl
Absorbance range 0.2 - 75A (10 mm equivalent absorbance)
Wavelength range 200 - 800 nm
Path length 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy ± 1 nm
Wavelength Resolution ≤ 3 nm (FWHM at Hg 546 nm)
Wavelength Range 900 nm to 2500 nm
Wavelength Accuracy ≤ 0.2
Wavelength Reproducibility ≤ 0.05
Bandwidth 8 nm

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 1 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm