Table Top Spectrophotometer LTS-A16 works on dual optical path spectrum analysis technology with full wavelength range for color and transmittance measurement. It adopts reflectance D/8° and transmittance D/0° geometry to measure both opaque and transparent materials. Four types of UV modes are used for fluorescence material measurement. Equipped with touch screen rotatable display screen and android operating system. It is ideal used for color measurement in textile, chemical, petroleum, oil industries.
| Wavelength Range | 360 nm to 780 nm |
| Wavelength Pitch | 10 nm |
| Sensor | Silicon Photodiode Array |
| Grating Method | Concave Grating |
| Sphere Diameter | 152 mm |
| Half Band Width | 5 nm |
| Reflectance Range | 0 to 200 % |
| Resolution | 0.0001 |
| Light Source | Pulse Xenon Lamp<br/> LED |
| UV Measurement | Include UV, 400nm cut, 420nm cut, 460nm cut |
| Operating Temperature | 5 ℃ to 40 ℃ |
| Storage Temperature | -20 ℃ to 45 ℃ |
| Relative Humidity | 80 % RH (at 35 ℃) |
| Measurement Time | SCI/SCE < 2<br/> SCI+SCE < 4s |
| Measurement Aperture | Reflectance: XLAV Φ30mm<br/> LAV 18mm,MAV Φ11mm<br/> SAV Φ6mm<br/> Transmittance:Φ25mm (Auto aperture size recognition) |
| Viewing Angles | 2° and 10° |
| Transmittance Sample Size | No limit on sample width and height<br/> Thickness ≤ 50mm |
| Repeatability | XLAV Spectrum Reflectance/Transmittance: standard deviation within 0.1%<br/> XLAV Chromaticity value: Standard deviation within ΔE*ab 0.015 * When a white calibration plate is measured 30 x at 5-second intervals after white calibration |
| Inter-Instrument Agreement | XLAV ΔE*ab 0.15 (BCRA Series II, Average measurement of 12 tiles, at 23℃) |
| Illuminants | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,DLF,NBF,TL83,TL84 |
| Display | Reflectance and Transmittance graph/value, color value, color difference values, pass/fail, color simulation, color assessment, haze, liquid chromaticity values, color tendency |
| Color Spaces | L*a*b, L*C*h, Hunter Lab, Yxy, XYZ |
| Color Difference | ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00, ΔE*ab(hunter),555 shade sort |
| Other Indices | WI(ASTM E313-00,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Stensby),YI(ASTM D1925,ASTM E313-00,ASTM E313-73),Tint(ASTM E313-00),Metamerism index milm, stain fastness, color fastness, ISO brightness, R457, A density, T density, E density, M Density, APHA/Pt-Co/Hazen, Gardner, Saybolt, ASTM color, Haze, Total Transmittance, Opacity, Color Strength |
| Other Functions | 1. Camera to view measurement area<br/> 2. Support horizontal, vertical and downward measurement method (need optional accessories to support for downward measurement)<br/> 3. Auto humidity and temperature compensation function |
| Illumination/ Viewing System | Reflection: d/8(Diffused illumination, 8 degree viewing) Simultaneous measurement of SCI/SCE (ISO7724/1, CIE No.15, ASTM E1164, ASTM-D1003-07, DIN5033 Teil7,JIS Z8722 Condition C standard) Transmittance d/0(Diffused illumination, 0 degree viewing ) |
| Interface | USB<br/> USB-B<br/> RS-232 |
| Screen Size | 7 Inches Touch Screen |
| Storage Memory | 8 GB U Disk for data storage and transfer |
| Power | 12V/3A |
| Dimensions (L × W × H) | 430 × 240 × 260 mm |
| Weight | 10.8 kg |
| Illumination system | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
| Wavelength Range | 400 nm to 700 nm |
| Wavelength Interval | 10 nm |
| Sensor | High sensitivity silicon photodiode |
| Illumination system | d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement |
| Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
| Illumination system | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Size of integrated sphere | 15.2 cm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
| Illumination system | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 1.0 to 5.0 nm (adjustable) |
| Optical system | Double beam, C-T monochromator, 1600 L/mm holographic grating |
| Wavelength Range | 190 ~ 1100 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 nm adjustable |
| Wavelength Range | 190 to 1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Optical System | Double beam |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength Range | 190 to 1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Optical System | Double beam, C-T monochromator,1200 L/mm holographic grating |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 1 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength Range | 190 to 1100 nm |
| Spectral Bandwidth | 1.0 nm |
| Optical System | Double beam |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 0.5/1/2/4/5 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength range | 190 ~ 1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength accuracy | 0.5 nm |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 0.5/1/2/4 nm |
| Wavelength Accuracy | ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 1.8 nm |
| Optical system | Double beam; 1200 lines/mm grating |
We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.
| Wavelength | 260 nm and 280 nm; Fixed |
| Spectral resolution | ≤ 8 nm |
| Path length | 0.5 mm |
| Wavelength range | 190 to 850 nm |
| Wavelength accuracy | ± 1 nm |
| Wavelength Resolution | 2 nm (FWHM at Hg 546 nm) |
We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations
| Wavelength Range | 190 ~ 1100 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 4 nm |
| Wavelength Range | 200 to 1000 nm |
| Spectral Bandwidth | 4.0 nm |
| Optical System | Single beam |
| Wavelength Range | 190 ~ 1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Range | 190 ~ 1100 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 1.8 nm |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 1 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength Range | 190 ~ 1100 nm |
| Spectral Bandwidth | 0.5 nm, 1 nm, 2 nm, 4 nm adjustable |
| Wavelength Range | 190 ~ 1100 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 0.5/1/2/4/5 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength Range | 190 ~ 1100 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 2 nm |
| Wavelength Range | 190 ~ 1100 nm |
| Spectral Bandwidth | 1 nm |
Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.
| Photometry | Single Beam |
| Monochromatic Type | Czerny-Turner |
| Wavelength range | 325 to 1000nm |
| Wavelength range | 320 to 1100 nm |
| Spectral bandwidth | 2.0 nm |
| Wavelength Accuracy | ± 0.8 nm |
| Photometry | Single Beam |
| Monochromatic Type | Czerny-Turner |
| Wavelength range | 340 to 1000nm |
| Wavelength Range | 325 ~ 1000 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 2 nm |
Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.
| Wavelength range | 190 nm ~ 900 nm |
| Spectral bandwidth | 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm |
| Wavelength accuracy | ± 0.25 nm |
| Wavelength range | 180 – 900 nm |
| Spectral Bandwidth | 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover) |
| Wavelength range | 190 - 900 nm |
| Spectral Bandwidth | 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm |
| Wavelength range | 180 – 900 nm |
| Spectral Bandwidth | 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting |
| Wavelength range | 180 - 900 nm |
| Spectral Bandwidth | 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting) |
| Working spectral range | 190 to 900 nm |
| Spectral Bandwith | 0.1, 0.2, 0.4, 1.0 and 2.0 nm |
| Wavelength accuracy | ± 0.15 nm |
| Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
| Sensor | High sensitivity silicon photodiode |
| Illumination | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.04 |
| Sensor | Photoelectric diode sensor |
| Optical Geometry | D/8 (diffused illumination,8° viewing), SCI (Specular Component Included), SCE (Specular Component Excluded) |
| Integrating Sphere Size | Φ 40 mm |
| Light Source | LED (Full band balanced LED) |
| Illumination | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03 |
| Sensor | Dual light path sensor array |
| Optical Geometry | D/8 (diffused illumination,8° viewing), Specular Component Included (SCI) |
| Integrating Sphere Size | Φ 40 mm |
| Light Source | LED (Full band balanced LED) |
| Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
| Sensor | High sensitivity silicon photodiode |
| Reflect | 8º(diffused illumination, 8 degree viewing angle) |
| Optical Geometry | SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source |
| Standards | ISO7724-1, ASTM E1164, DIN5033 Teil7 |
| Illumination | Observation angles 2°/10°<br/> Illumination: d/8 (Diffused lighting, 8° observation angle)<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement<br/> |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04 |
| Sensor | Dual light path sensor array |
| Illumination | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.05 |
| Sensor | Photoelectric diode sensor |
| Reflect | 8º(diffused illumination, 8 degree viewing angle) |
| Optical Geometry | SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source |
| Standards | ISO7724-1, ASTM E1164, DIN5033 Teil7 |
| Illumination | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.05 |
| Sensor | Blue light enhanced sensor array |
| Wavelength Range | 900 nm to 2500 nm |
| Wavelength Accuracy | ≤ 0.2 |
| Wavelength Reproducibility | ≤ 0.05 |
| Light source | 150 W Xenon lamp |
| Excitation wavelength | 200 nm to 900 nm |
| Emission wavelength | 200 nm to 900 nm |
| Excitation Source | 150 W Xenon Lamp |
| Excitation Wavelength | 200 nm to 900 nm |
| Excitation Slit | 1 nm, 2 nm, 5 nm, 10 nm, 20 nm |
| Light source | 150 W Xenon lamp |
| Excitation wavelength | 200 nm to 900 nm |
| Emission wavelength | 200 nm to 900 nm |
| Optical system | Double Beam, Grating 1200 lines/mm |
| Wavelength Range | 190 nm to 1100 nm |
| Spectral Bandwidth | 2 nm |
| Optical system | Double Beam, Grating 1200 lines/mm |
| Wavelength Range | 190 nm to 1100 nm |
| Spectral Bandwidth | 1 nm |
| Optical system | Double Beam, Grating 1200 lines/mm |
| Wavelength Range | 190 nm to 1100 nm |
| Spectral Bandwidth | 1 nm |
| Optical system | Double Beam, Grating 1200 lines/mm |
| Wavelength Range | 190 nm to 1100 nm |
| Spectral Bandwidth | 2 nm |