NIR Spectrophotometer LNIR-A10 is a spectrophotometer with grating monochromator. The wavelength range is 900 nm to 2500 nm and temperature ranges from 5 to 35℃. Single channel whole spectrum scanning offers low dark noise and high sensitivity. It features built-in high-quality PTFE reference module and polystyrene wavelength standard filter. It combines the data with the corresponding NIR data model, various components of the tested sample can be obtained at the same time. The device is used for rapid non-destructive analysis of oil, alcohol, beverage and other liquids.

Wavelength Range 900 nm to 2500 nm
Wavelength Accuracy ≤ 0.2
Wavelength Reproducibility ≤ 0.05
Bandwidth 8 nm
Measurement Mode Transmission
Optical System Grating Monochromator
Stray Light ≤0.1 %
Noise ≤ 0.0005 Abs
Analysis time 1 minute or above
Port USB 2.0
Temperature Requirement 5 to 35℃
Humidity Requirement 5 to 85 % RH
Dimension 360 × 460 × 240 mm
Power Supply 90 to 250 V, 50/60 Hz
Weight 12 kg
  • Designed with single channeled whole spectrum scanning
  • Wavelength range is 900 to 2500 nm
  • Built-in high-quality PTFE reference module and polystyrene wavelength standard filter
  • Equipped with automatic reference calibration and monitoring wavelengths ensure accurate and stable measurement results
  • Designed with ambient temperature and humidity in real time and stores it in spectrum file
  • Offers 8 nm bandwidth
  • Photomultiplier tube detection
  • Easy to use, no sample preparation is required and the sample is not damaged

NIR Spectrophotometer is used in chemical and Polymer QA/QC, quantitative analysis of production samples, simple quantification of binary and ternary mixtures , identification of colored gemstones, color origin in colored diamonds, identification of geographical origin for sapphires and emeralds, telecommunication, laser characterization.

Wavelength Range 900 nm to 2500 nm
Wavelength Accuracy ≤ 0.2
Wavelength Reproducibility ≤ 0.05
Bandwidth 8 nm
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 1 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm
Wavelength repeatability ≤ 0.04 nm
Wavelength range 180 - 900 nm
Spectral Bandwidth 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Wavelength range 190 - 900 nm
Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength accuracy ≤ ± 0.5 nm
Wavelength repeatability ≤ 0.3 nm(single direction)
Wavelength Range 360 nm to 780 nm
Wavelength Pitch 10 nm
Sensor Silicon Photodiode Array
Grating Method Concave Grating
Wavelength Range 400 nm to 700 nm
Wavelength Interval 10 nm
Sensor High sensitivity silicon photodiode
Light Source LED
Illumination system d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination light source CLED
Sensor Dual light path sensor array