Single Beam UV/Visible Spectrophotometer LUS-A22

Single Beam UV/Visible Spectrophotometer LUS-A22 comes with a wide wavelength range of 190 - 1100 nm with adjustable spectral bandwidth of 0.5 nm, 1 nm, 2 nm, 4 nm. It has a PC software to provide reliable measurements results. The wide range of measurement methods e.g. wavelength scanning, time scanning, microarray measurement meets the different range of applications.

Wavelength Range 190 ~ 1100 nm
Setting Wavelength
Spectral Bandwidth 0.5 nm, 1 nm, 2 nm, 4 nm adjustable
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability ≤ 0.1 nm
Photometric Range (-4)A to 4 A
Photometric Mode T,A,C,E
Photometric Accuracy ± 0.3 % τ(0 - 100 % τ) ± 0.002 A (0 to 0.5 A) ± 0.003 A(0.5 A to 1 A)
Photometric Repeatability 0.15 % τ(0 - 100 % τ); ± 0.001 A(0 to 0.5 A); ± 0.0015 A(0.5 A to 1 A)
Transmittance accuracy
Transmittance repeatability
Detector Imported Silicon Photodiode
Light Source Imported Deuterium Lamp & Tungsten Halogen Lamp
Stray Light ≤ 0.05 % T at 220 nm, 360 nm
Stability 0.0005 A / h at 500 nm
Data Output Port
Power Requirement AC 220 V / 50 Hz, 110 V / 60 Hz.
Dimensions 560 × 450 × 230 mm
Noise ± 0.0002 A at 500 nm
Weight 28 kg
Gross Weight
Net Weight
Power 120 W
Display LCD 6 inches blue LCD
Optical System
Baseline Linearity
Baseline Drift
Baseline Flatness ± 0.001 A
Printer Port
Packing Size
Software
Packing Weight
  • Wide wavelength range of 190 - 1100 nm
  • 4 spectral bandwidth (4.0 nm, 2.0 nm, 1.0 nm, 0.5 nm)
  • 6 inches large LCD screen to display measurement parameters & readings
  • Improved and optimized optical design, light source and receiver system
  • Automatic wavelength adjustment
  • Wide range of measurement methods: wavelength scanning, time scanning, microarray measurement
  • Adapted with PC software to measure more precise measurements
  • Large scale integrated circuit design to improve the scalability and reliability of the system
  • Measurement data can be output through the printer with USB interface

Single beam UV/VIS spectrophotometer has applications in pharmaceutical analysis, biological research, chemistry, environmental science, food science, medicine & other fields.

Related Products of Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Wavelength Range 190 ~ 1100 nm
Spectral Bandwidth 1 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability 0.2 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength Range 190 ~ 1100 nm
Spectral Bandwidth 1.8 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability 0.2 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength Range 200 to 1000 nm
Spectral Bandwidth 4.0 nm
Optical System Single beam
Wavelength Accuracy ±0.2 nm
Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.5 nm
Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 1.8 nm
Wavelength Accuracy ± 0.3 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 4 nm
Wavelength Accuracy ± 0.5 nm
Wavelength Range 190 ~ 1100 nm
Spectral Bandwidth 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability 0.2 nm
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Test angle -
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Test angle 60°
Illumination d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.05
Sensor Blue light enhanced sensor array
Size of integrated sphere 40 mm, alvan diffused reflection surface coating

Single Beam UV/Visible Spectrophotometer

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm
Wavelength repeatability ≤ 0.04 nm
Wavelength range 180 - 900 nm
Spectral Bandwidth 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Wavelength range 190 - 900 nm
Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength accuracy ≤ ± 0.5 nm
Wavelength repeatability ≤ 0.3 nm(single direction)
Excitation Source 150 W Xenon Lamp
Excitation Wavelength 200 nm to 900 nm
Excitation Slit 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Emission Slit 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm
Excitation slit 2 nm, 5 nm, 10 nm, 20 nm
Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm
Excitation slit 2 nm, 5 nm, 10 nm, 20 nm

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm