Nano Spectrophotometer LNS-B11

Nano spectrophotometer LNS-B11 is micro volume UV spectrophotometer which takes measurements at 230 nm, 260 nm, 280 nm. It utilizes CCD detector, Xenon flash lamp as light source which has high stability and long operating life. They are used to detect micro volume quantities of nucleic acids and other concentrated or dilute components is specially designed to analyze the concentration of pure of nucleic acid. The data can be printed with built in printer and can be transferred via SD- RAM card or USB. It requires only minimal amount of sample for accurate measurement.

Cuvette
Temperature
PC
Wavelength range 230 nm, 260 nm, 280 nm
Path length 1.0 mm, 0.2 mm
Wavelength accuracy
Wavelength Resolution
Path length of cuvette
Minimum Sample size 0.3 - 2.0 µl
Absorbance range 0.2 - 75A (10 mm equivalent absorbance)
Precision of wavelength
Absorbance precision 0.002 Abs
Absorbance accuracy 0.01
Light source Xenon flash lamp
Measurement time < 5 s
Operating Voltage
Sample Pedestal Material
Detector Type
Screen
Software Compatibility
Detects nucleic acid up to 10 - 3750 ng/µL (dsDNA)
Detects protein up to 0.5 - 110 mg/mL (BSA)
Data Output
Operating Power Consumption
Standby Power Consumption
Dimension 240 x 220 x 140 mm
Weight 2.35 kg
  • Wavelength measurement at 230 nm, 260 nm, 280 nm
  • 0.5 µl - 2.0 µl micro-volume sample for direct measurement onto pedestal
  • Rapid measure speed
  • Touch screen & panel operations with user friendly software
  • Long life Xenon flash lamp (10 flashes up to 10 years)
  • Highly concentrated samples can be used
  • Direct Concentration display
  • No cell or cuvettes are required
  • No necessary of PC

The nano spectrophotometer is used in laboratory, food industries, chemistry, microbiology, medicine research and development.

Related Products of Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Wavelength range 200 - 850 nm
Path length 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy ± 1 nm
Wavelength Resolution 2 nm (FWHM at Hg 546 nm)
Wavelength range 190 to 850 nm
Wavelength accuracy ± 1 nm
Wavelength Resolution 2 nm (FWHM at Hg 546 nm)
Cuvette details Recyclable micro cuvette, 8.5 mm sample level height
Cuvette No
PC Inbuilt
Wavelength range 190 - 850 nm
Path length 1 mm, 0.2 mm ,0.04 mm
Wavelength 260 nm and 280 nm; Fixed
Spectral resolution ≤ 8 nm
Path length 0.5 mm
Minimum sample size 1 to 2 µl
Cuvette Yes
PC Inbuilt
Wavelength range 190 - 850 nm
Path length 1 mm, 0.2 mm ,0.04 mm
Cuvette Yes
Temperature 4 ºC - 42 ºC (Heating & Cooling)
PC Inbuilt
Wavelength range 190 - 850 nm
Cuvette Yes
Temperature Room Temperature 42 ºC
PC Inbuilt
Wavelength range 190 - 850 nm
Wavelength range 200 - 800 nm
Path length 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy ± 1 nm
Wavelength Resolution ≤ 3 nm (FWHM at Hg 546 nm)
Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm
Excitation slit 2 nm, 5 nm, 10 nm, 20 nm
Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm
Excitation slit 2 nm, 5 nm, 10 nm, 20 nm
Excitation Source 150 W Xenon Lamp
Excitation Wavelength 200 nm to 900 nm
Excitation Slit 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Emission Slit 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Illumination d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.05
Sensor Blue light enhanced sensor array
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Test angle 60°
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Test angle -

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Wavelength range 180 - 900 nm
Spectral Bandwidth 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Wavelength range 190 - 900 nm
Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength accuracy ≤ ± 0.5 nm
Wavelength repeatability ≤ 0.3 nm(single direction)
Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm
Wavelength repeatability ≤ 0.04 nm
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 1 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all
Optical system Double Beam, Grating 1200 lines/mm
Wavelength Range 190 nm to 1100 nm
Spectral Bandwidth 2 nm
Wavelength Accuracy ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5/1/2/4/5 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm
Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability ≤ 0.1 nm