Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 2 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 1 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 0.5/1/2/4/5 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Repeatability | ≤ 0.1 nm |
Optical system | Double Beam, Grating 1200 lines/mm |
Wavelength Range | 190 nm to 1100 nm |
Spectral Bandwidth | 2 nm |
Wavelength Accuracy | ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all |
Optical system | Double Beam, Grating 1200 lines/mm |
Wavelength Range | 190 nm to 1100 nm |
Spectral Bandwidth | 1 nm |
Wavelength Accuracy | ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all |
Optical system | Double Beam, Grating 1200 lines/mm |
Wavelength Range | 190 nm to 1100 nm |
Spectral Bandwidth | 2 nm |
Wavelength Accuracy | ± 0.1 nm @ 656.1 nm, ± 0.3 nm @ all |
Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
Sensor | High sensitivity silicon photodiode |
Test angle | 60° |
Illumination | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Repeatability | Light splitting reflectivity:standard deviation within 0.08%<br/> Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)<br/> Maximum:0.05 |
Sensor | Blue light enhanced sensor array |
Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
Sensor | High sensitivity silicon photodiode |
Test angle | - |
Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.
Wavelength range | 180 - 900 nm |
Spectral Bandwidth | 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting) |
Wavelength accuracy | ≤ 0.15 nm |
Wavelength repeatability | ± 0.1 nm |
Working spectral range | 190 to 900 nm |
Spectral Bandwith | 0.1, 0.2, 0.4, 1.0 and 2.0 nm |
Wavelength accuracy | ± 0.15 nm |
Wavelength repeatability | ≤ 0.04 nm |
Wavelength range | 190 - 900 nm |
Spectral Bandwidth | 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm |
Wavelength accuracy | ≤ ± 0.5 nm |
Wavelength repeatability | ≤ 0.3 nm(single direction) |
Wavelength Range | 900 nm to 2500 nm |
Wavelength Accuracy | ≤ 0.2 |
Wavelength Reproducibility | ≤ 0.05 |
Bandwidth | 8 nm |